From owner-freebsd-scsi@FreeBSD.ORG Mon Dec 8 15:58:20 2014 Return-Path: Delivered-To: freebsd-scsi@freebsd.org Received: from mx1.freebsd.org (mx1.freebsd.org [IPv6:2001:1900:2254:206a::19:1]) (using TLSv1.2 with cipher AECDH-AES256-SHA (256/256 bits)) (No client certificate requested) by hub.freebsd.org (Postfix) with ESMTPS id 69C8C92D for ; Mon, 8 Dec 2014 15:58:20 +0000 (UTC) Received: from mail-qa0-f53.google.com (mail-qa0-f53.google.com [209.85.216.53]) (using TLSv1 with cipher ECDHE-RSA-RC4-SHA (128/128 bits)) (Client CN "smtp.gmail.com", Issuer "Google Internet Authority G2" (verified OK)) by mx1.freebsd.org (Postfix) with ESMTPS id EE2DA5EB for ; Mon, 8 Dec 2014 15:58:19 +0000 (UTC) Received: by mail-qa0-f53.google.com with SMTP id bm13so3470997qab.40 for ; Mon, 08 Dec 2014 07:58:18 -0800 (PST) X-Google-DKIM-Signature: v=1; a=rsa-sha256; c=relaxed/relaxed; d=1e100.net; s=20130820; h=x-gm-message-state:content-type:mime-version:subject:from :in-reply-to:date:cc:content-transfer-encoding:message-id:references :to; bh=u2BVHNWVIvyTvDIHE5Rl3lFtvltQlWtf+JV3a24P7UM=; b=i+NaCJYG5WT9Bl4gaLCpir5NgDtewKu6qYZ6qOckmPqWS5o+KpiRoIPg5l0DSnSAIs uG+M9Rvwwkk+NrAbWLLexbb51gSsFOLgxfSoD1C6T0okhD4LM22JuHkdAW7xq6onju0j YkHwW8D+WB8iQoNDgAF1k9+AI46icK/vJHUrSM5cJ+8wZeIUlnyMsAp4wV4dlgXFmE84 /4RjS6GzU9BTb87XtXi3EyQ7hawtCjhzo97q/Z9ht1ZUSmEeQuyqD5vpsbOeoWlglS4a xlQ3/UfoPKHScv12m/9oaaoCpKPjZq8gMT0yIcKoMqYHthzfnJQhWDfaocoxdADVJogt Q4/A== X-Gm-Message-State: ALoCoQneY8aUjeBJy9H3ZyyCM1zPWIzEQN9n809cGwRkzyUyPKfPC6Lo9T8UZUKkal8OhHOdOz2s X-Received: by 10.140.39.201 with SMTP id v67mr51756393qgv.45.1418054298435; Mon, 08 Dec 2014 07:58:18 -0800 (PST) Received: from [10.1.1.2] (pool-71-184-234-181.bstnma.fios.verizon.net. [71.184.234.181]) by mx.google.com with ESMTPSA id p67sm38077048qga.26.2014.12.08.07.58.16 for (version=TLSv1 cipher=ECDHE-RSA-RC4-SHA bits=128/128); Mon, 08 Dec 2014 07:58:17 -0800 (PST) Content-Type: text/plain; charset=us-ascii Mime-Version: 1.0 (Mac OS X Mail 6.6 \(1510\)) Subject: Re: LSI SAS 3008 card - 35 out of 36 disks detected From: Justin O'Conor In-Reply-To: Date: Mon, 8 Dec 2014 10:58:14 -0500 Content-Transfer-Encoding: quoted-printable Message-Id: References: <54822835.3080800@crystal.harvard.edu> To: Alan Somers X-Mailer: Apple Mail (2.1510) Cc: FreeBSD-scsi X-BeenThere: freebsd-scsi@freebsd.org X-Mailman-Version: 2.1.18-1 Precedence: list List-Id: SCSI subsystem List-Unsubscribe: , List-Archive: List-Post: List-Help: List-Subscribe: , X-List-Received-Date: Mon, 08 Dec 2014 15:58:20 -0000 Hi All, Thanks, this is encouraging. smp_discover ses0|1 see 36 sata disks. This = is from the 10.1 install. Lets start with the short ones - root@rhea:~ # sg_inq --hex --len=3D64 ses0 00 0d 00 05 02 34 00 40 02 4c 53 49 20 20 20 20 20 ....4.@.LSI = =20 10 53 41 53 32 58 33 36 20 20 20 20 20 20 20 20 20 SAS2X36 = =20 20 30 65 31 32 78 33 36 2d 35 35 2e 31 34 2e 31 38 = 0e12x36-55.14.18 30 2e 30 00 20 20 20 20 20 .0. =20 root@rhea:~ # sg_inq --hex --len=3D64 ses1 00 0d 00 05 02 34 00 40 02 4c 53 49 20 20 20 20 20 ....4.@.LSI = =20 10 53 41 53 32 58 32 38 20 20 20 20 20 20 20 20 20 SAS2X28 = =20 20 30 65 31 32 78 33 36 2d 35 35 2e 31 34 2e 31 38 = 0e12x36-55.14.18 30 2e 30 00 20 20 20 20 20=20 root@rhea:~ # smp_discover ses0 phy 0:S:attached:[500605b009150c20:02 i(SSP+STP+SMP)] 6 Gbps phy 1:S:attached:[500605b009150c20:03 i(SSP+STP+SMP)] 6 Gbps phy 2:S:attached:[500605b009150c20:01 i(SSP+STP+SMP)] 6 Gbps phy 3:S:attached:[500605b009150c20:00 i(SSP+STP+SMP)] 6 Gbps phy 4:U:attached:[50030480017bd5bf:00 exp t(SMP)] 6 Gbps phy 5:U:attached:[50030480017bd5bf:01 exp t(SMP)] 6 Gbps phy 6:U:attached:[50030480017bd5bf:02 exp t(SMP)] 6 Gbps phy 7:U:attached:[50030480017bd5bf:03 exp t(SMP)] 6 Gbps phy 12:U:attached:[50030480017ae20c:00 t(SATA)] 6 Gbps phy 13:U:attached:[50030480017ae20d:00 t(SATA)] 6 Gbps phy 14:U:attached:[50030480017ae20e:00 t(SATA)] 6 Gbps phy 15:U:attached:[50030480017ae20f:00 t(SATA)] 6 Gbps phy 16:U:attached:[50030480017ae210:00 t(SATA)] 6 Gbps phy 17:U:attached:[50030480017ae211:00 t(SATA)] 6 Gbps phy 18:U:attached:[50030480017ae212:00 t(SATA)] 6 Gbps phy 19:U:attached:[50030480017ae213:00 t(SATA)] 6 Gbps phy 20:U:attached:[50030480017ae214:00 t(SATA)] 6 Gbps phy 21:U:attached:[50030480017ae215:00 t(SATA)] 6 Gbps phy 22:U:attached:[50030480017ae216:00 t(SATA)] 6 Gbps phy 23:U:attached:[50030480017ae217:00 t(SATA)] 6 Gbps phy 24:U:attached:[50030480017ae218:00 t(SATA)] 6 Gbps phy 25:U:attached:[50030480017ae219:00 t(SATA)] 6 Gbps phy 26:U:attached:[50030480017ae21a:00 t(SATA)] 6 Gbps phy 27:U:attached:[50030480017ae21b:00 t(SATA)] 6 Gbps phy 28:U:attached:[50030480017ae21c:00 t(SATA)] 6 Gbps phy 29:U:attached:[50030480017ae21d:00 t(SATA)] 6 Gbps phy 30:U:attached:[50030480017ae21e:00 t(SATA)] 6 Gbps phy 31:U:attached:[50030480017ae21f:00 t(SATA)] 6 Gbps phy 32:U:attached:[50030480017ae220:00 t(SATA)] 6 Gbps phy 33:U:attached:[50030480017ae221:00 t(SATA)] 6 Gbps phy 34:U:attached:[50030480017ae222:00 t(SATA)] 6 Gbps phy 35:U:attached:[50030480017ae223:00 t(SATA)] 6 Gbps phy 36:D:attached:[50030480017ae23d:00 V i(SSP+SMP) t(SSP)] 6 Gbps root@rhea:~ # foreach PHY ( `seq 0 1 36` ) foreach? smp_discover -p $PHY ses0 foreach? end Discover response: expander change count: 1328 phy identifier: 0 attached device type: SAS or SATA device attached reason: power on negotiated logical link rate: phy enabled, 6 Gbps attached initiator: ssp=3D1 stp=3D1 smp=3D1 sata_host=3D0 attached sata port selector: 0 STP buffer too small: 0 attached target: ssp=3D0 stp=3D0 smp=3D0 sata_device=3D0 SAS address: 0x50030480017ae23f attached SAS address: 0x500605b009150c20 attached phy identifier: 2 attached persistent capable: 0 attached power capable: 0 attached slumber capable: 0 attached partial capable: 0 attached inside ZPSDS persistent: 0 attached requested inside ZPSDS: 0 attached break_reply capable: 1 attached pwr_dis capable: 0 programmed minimum physical link rate: 1.5 Gbps hardware minimum physical link rate: 1.5 Gbps programmed maximum physical link rate: 6 Gbps hardware maximum physical link rate: 6 Gbps phy change count: 33 virtual phy: 0 partial pathway timeout value: 7 us routing attribute: subtractive connector type: No information connector element index: 0 connector physical link: 0 phy power condition: 0 sas power capable: 0 sas slumber capable: 0 sas partial capable: 0 sata slumber capable: 0 sata partial capable: 0 pwr_dis signal: 0 pwr_dis control capable: 0 sas slumber enabled: 0 sas partial enabled: 0 sata slumber enabled: 0 sata partial enabled: 0 attached device name: 0x500605b009150c20 requested inside ZPSDS changed by expander: 0 inside ZPSDS persistent: 0 requested inside ZPSDS: 0 zone group persistent: 1 inside ZPSDS: 0 zoning enabled: 0 zone group: 1 self-configuration status: 0 self-configuration levels completed: 0 self-configuration sas address: 0x0 programmed phy capabilities: 0x0 current phy capabilities: 0x0 attached phy capabilities: 0x0 reason: unknown negotiated physical link rate: phy enabled, 6 Gbps optical mode enabled: 0 negotiated SSC: 0 hardware muxing supported: 0 default inside ZPSDS persistent: 0 default requested inside ZPSDS: 0 default zone group persistent: 1 default zoning enabled: 0 default zone group: 1 saved inside ZPSDS persistent: 0 saved requested inside ZPSDS: 0 saved zone group persistent: 1 saved zoning enabled: 0 saved zone group: 1 shadow inside ZPSDS persistent: 0 shadow requested inside ZPSDS: 0 shadow zone group persistent: 1 shadow zoning enabled: 0 shadow zone group: 1 device slot number: 255 device slot group number: 255 device slot group output connector: =20 Discover response: expander change count: 1328 phy identifier: 1 attached device type: SAS or SATA device attached reason: power on negotiated logical link rate: phy enabled, 6 Gbps attached initiator: ssp=3D1 stp=3D1 smp=3D1 sata_host=3D0 attached sata port selector: 0 STP buffer too small: 0 attached target: ssp=3D0 stp=3D0 smp=3D0 sata_device=3D0 SAS address: 0x50030480017ae23f attached SAS address: 0x500605b009150c20 attached phy identifier: 3 attached persistent capable: 0 attached power capable: 0 attached slumber capable: 0 attached partial capable: 0 attached inside ZPSDS persistent: 0 attached requested inside ZPSDS: 0 attached break_reply capable: 1 attached pwr_dis capable: 0 programmed minimum physical link rate: 1.5 Gbps hardware minimum physical link rate: 1.5 Gbps programmed maximum physical link rate: 6 Gbps hardware maximum physical link rate: 6 Gbps phy change count: 33 virtual phy: 0 partial pathway timeout value: 7 us routing attribute: subtractive connector type: No information connector element index: 0 connector physical link: 0 phy power condition: 0 sas power capable: 0 sas slumber capable: 0 sas partial capable: 0 sata slumber capable: 0 sata partial capable: 0 pwr_dis signal: 0 pwr_dis control capable: 0 sas slumber enabled: 0 sas partial enabled: 0 sata slumber enabled: 0 sata partial enabled: 0 attached device name: 0x500605b009150c20 requested inside ZPSDS changed by expander: 0 inside ZPSDS persistent: 0 requested inside ZPSDS: 0 zone group persistent: 1 inside ZPSDS: 0 zoning enabled: 0 zone group: 1 self-configuration status: 0 self-configuration levels completed: 0 self-configuration sas address: 0x0 programmed phy capabilities: 0x0 current phy capabilities: 0x0 attached phy capabilities: 0x0 reason: unknown negotiated physical link rate: phy enabled, 6 Gbps optical mode enabled: 0 negotiated SSC: 0 hardware muxing supported: 0 default inside ZPSDS persistent: 0 default requested inside ZPSDS: 0 default zone group persistent: 1 default zoning enabled: 0 default zone group: 1 saved inside ZPSDS persistent: 0 saved requested inside ZPSDS: 0 saved zone group persistent: 1 saved zoning enabled: 0 saved zone group: 1 shadow inside ZPSDS persistent: 0 shadow requested inside ZPSDS: 0 shadow zone group persistent: 1 shadow zoning enabled: 0 shadow zone group: 1 device slot number: 255 device slot group number: 255 device slot group output connector: =20 Discover response: expander change count: 1328 phy identifier: 2 attached device type: SAS or SATA device attached reason: power on negotiated logical link rate: phy enabled, 6 Gbps attached initiator: ssp=3D1 stp=3D1 smp=3D1 sata_host=3D0 attached sata port selector: 0 STP buffer too small: 0 attached target: ssp=3D0 stp=3D0 smp=3D0 sata_device=3D0 SAS address: 0x50030480017ae23f attached SAS address: 0x500605b009150c20 attached phy identifier: 1 attached persistent capable: 0 attached power capable: 0 attached slumber capable: 0 attached partial capable: 0 attached inside ZPSDS persistent: 0 attached requested inside ZPSDS: 0 attached break_reply capable: 1 attached pwr_dis capable: 0 programmed minimum physical link rate: 1.5 Gbps hardware minimum physical link rate: 1.5 Gbps programmed maximum physical link rate: 6 Gbps hardware maximum physical link rate: 6 Gbps phy change count: 33 virtual phy: 0 partial pathway timeout value: 7 us routing attribute: subtractive connector type: No information connector element index: 0 connector physical link: 0 phy power condition: 0 sas power capable: 0 sas slumber capable: 0 sas partial capable: 0 sata slumber capable: 0 sata partial capable: 0 pwr_dis signal: 0 pwr_dis control capable: 0 sas slumber enabled: 0 sas partial enabled: 0 sata slumber enabled: 0 sata partial enabled: 0 attached device name: 0x500605b009150c20 requested inside ZPSDS changed by expander: 0 inside ZPSDS persistent: 0 requested inside ZPSDS: 0 zone group persistent: 1 inside ZPSDS: 0 zoning enabled: 0 zone group: 1 self-configuration status: 0 self-configuration levels completed: 0 self-configuration sas address: 0x0 programmed phy capabilities: 0x0 current phy capabilities: 0x0 attached phy capabilities: 0x0 reason: unknown negotiated physical link rate: phy enabled, 6 Gbps optical mode enabled: 0 negotiated SSC: 0 hardware muxing supported: 0 default inside ZPSDS persistent: 0 default requested inside ZPSDS: 0 default zone group persistent: 1 default zoning enabled: 0 default zone group: 1 saved inside ZPSDS persistent: 0 saved requested inside ZPSDS: 0 saved zone group persistent: 1 saved zoning enabled: 0 saved zone group: 1 shadow inside ZPSDS persistent: 0 shadow requested inside ZPSDS: 0 shadow zone group persistent: 1 shadow zoning enabled: 0 shadow zone group: 1 device slot number: 255 device slot group number: 255 device slot group output connector: =20 Discover response: expander change count: 1328 phy identifier: 3 attached device type: SAS or SATA device attached reason: power on negotiated logical link rate: phy enabled, 6 Gbps attached initiator: ssp=3D1 stp=3D1 smp=3D1 sata_host=3D0 attached sata port selector: 0 STP buffer too small: 0 attached target: ssp=3D0 stp=3D0 smp=3D0 sata_device=3D0 SAS address: 0x50030480017ae23f attached SAS address: 0x500605b009150c20 attached phy identifier: 0 attached persistent capable: 0 attached power capable: 0 attached slumber capable: 0 attached partial capable: 0 attached inside ZPSDS persistent: 0 attached requested inside ZPSDS: 0 attached break_reply capable: 1 attached pwr_dis capable: 0 programmed minimum physical link rate: 1.5 Gbps hardware minimum physical link rate: 1.5 Gbps programmed maximum physical link rate: 6 Gbps hardware maximum physical link rate: 6 Gbps phy change count: 33 virtual phy: 0 partial pathway timeout value: 7 us routing attribute: subtractive connector type: No information connector element index: 0 connector physical link: 0 phy power condition: 0 sas power capable: 0 sas slumber capable: 0 sas partial capable: 0 sata slumber capable: 0 sata partial capable: 0 pwr_dis signal: 0 pwr_dis control capable: 0 sas slumber enabled: 0 sas partial enabled: 0 sata slumber enabled: 0 sata partial enabled: 0 attached device name: 0x500605b009150c20 requested inside ZPSDS changed by expander: 0 inside ZPSDS persistent: 0 requested inside ZPSDS: 0 zone group persistent: 1 inside ZPSDS: 0 zoning enabled: 0 zone group: 1 self-configuration status: 0 self-configuration levels completed: 0 self-configuration sas address: 0x0 programmed phy capabilities: 0x0 current phy capabilities: 0x0 attached phy capabilities: 0x0 reason: unknown negotiated physical link rate: phy enabled, 6 Gbps optical mode enabled: 0 negotiated SSC: 0 hardware muxing supported: 0 default inside ZPSDS persistent: 0 default requested inside ZPSDS: 0 default zone group persistent: 1 default zoning enabled: 0 default zone group: 1 saved inside ZPSDS persistent: 0 saved requested inside ZPSDS: 0 saved zone group persistent: 1 saved zoning enabled: 0 saved zone group: 1 shadow inside ZPSDS persistent: 0 shadow requested inside ZPSDS: 0 shadow zone group persistent: 1 shadow zoning enabled: 0 shadow zone group: 1 device slot number: 255 device slot group number: 255 device slot group output connector: =20 Discover response: expander change count: 1328 phy identifier: 4 attached device type: expander device attached reason: SMP phy control requested negotiated logical link rate: phy enabled, 6 Gbps attached initiator: ssp=3D0 stp=3D0 smp=3D0 sata_host=3D0 attached sata port selector: 0 STP buffer too small: 0 attached target: ssp=3D0 stp=3D0 smp=3D1 sata_device=3D0 SAS address: 0x50030480017ae23f attached SAS address: 0x50030480017bd5bf attached phy identifier: 0 attached persistent capable: 0 attached power capable: 0 attached slumber capable: 0 attached partial capable: 0 attached inside ZPSDS persistent: 0 attached requested inside ZPSDS: 0 attached break_reply capable: 1 attached pwr_dis capable: 0 programmed minimum physical link rate: 1.5 Gbps hardware minimum physical link rate: 1.5 Gbps programmed maximum physical link rate: 6 Gbps hardware maximum physical link rate: 6 Gbps phy change count: 4 virtual phy: 0 partial pathway timeout value: 7 us routing attribute: table connector type: No information connector element index: 0 connector physical link: 0 phy power condition: 0 sas power capable: 0 sas slumber capable: 0 sas partial capable: 0 sata slumber capable: 0 sata partial capable: 0 pwr_dis signal: 0 pwr_dis control capable: 0 sas slumber enabled: 0 sas partial enabled: 0 sata slumber enabled: 0 sata partial enabled: 0 attached device name: 0x50030480017bd5bf requested inside ZPSDS changed by expander: 0 inside ZPSDS persistent: 0 requested inside ZPSDS: 0 zone group persistent: 1 inside ZPSDS: 0 zoning enabled: 0 zone group: 1 self-configuration status: 0 self-configuration levels completed: 1 self-configuration sas address: 0x0 programmed phy capabilities: 0x0 current phy capabilities: 0x0 attached phy capabilities: 0x0 reason: unknown negotiated physical link rate: phy enabled, 6 Gbps optical mode enabled: 0 negotiated SSC: 0 hardware muxing supported: 0 default inside ZPSDS persistent: 0 default requested inside ZPSDS: 0 default zone group persistent: 1 default zoning enabled: 0 default zone group: 1 saved inside ZPSDS persistent: 0 saved requested inside ZPSDS: 0 saved zone group persistent: 1 saved zoning enabled: 0 saved zone group: 1 shadow inside ZPSDS persistent: 0 shadow requested inside ZPSDS: 0 shadow zone group persistent: 1 shadow zoning enabled: 0 shadow zone group: 1 device slot number: 255 device slot group number: 255 device slot group output connector: =20 Discover response: expander change count: 1328 phy identifier: 5 attached device type: expander device attached reason: SMP phy control requested negotiated logical link rate: phy enabled, 6 Gbps attached initiator: ssp=3D0 stp=3D0 smp=3D0 sata_host=3D0 attached sata port selector: 0 STP buffer too small: 0 attached target: ssp=3D0 stp=3D0 smp=3D1 sata_device=3D0 SAS address: 0x50030480017ae23f attached SAS address: 0x50030480017bd5bf attached phy identifier: 1 attached persistent capable: 0 attached power capable: 0 attached slumber capable: 0 attached partial capable: 0 attached inside ZPSDS persistent: 0 attached requested inside ZPSDS: 0 attached break_reply capable: 1 attached pwr_dis capable: 0 programmed minimum physical link rate: 1.5 Gbps hardware minimum physical link rate: 1.5 Gbps programmed maximum physical link rate: 6 Gbps hardware maximum physical link rate: 6 Gbps phy change count: 4 virtual phy: 0 partial pathway timeout value: 7 us routing attribute: table connector type: No information connector element index: 0 connector physical link: 0 phy power condition: 0 sas power capable: 0 sas slumber capable: 0 sas partial capable: 0 sata slumber capable: 0 sata partial capable: 0 pwr_dis signal: 0 pwr_dis control capable: 0 sas slumber enabled: 0 sas partial enabled: 0 sata slumber enabled: 0 sata partial enabled: 0 attached device name: 0x50030480017bd5bf requested inside ZPSDS changed by expander: 0 inside ZPSDS persistent: 0 requested inside ZPSDS: 0 zone group persistent: 1 inside ZPSDS: 0 zoning enabled: 0 zone group: 1 self-configuration status: 0 self-configuration levels completed: 1 self-configuration sas address: 0x0 programmed phy capabilities: 0x0 current phy capabilities: 0x0 attached phy capabilities: 0x0 reason: unknown negotiated physical link rate: phy enabled, 6 Gbps optical mode enabled: 0 negotiated SSC: 0 hardware muxing supported: 0 default inside ZPSDS persistent: 0 default requested inside ZPSDS: 0 default zone group persistent: 1 default zoning enabled: 0 default zone group: 1 saved inside ZPSDS persistent: 0 saved requested inside ZPSDS: 0 saved zone group persistent: 1 saved zoning enabled: 0 saved zone group: 1 shadow inside ZPSDS persistent: 0 shadow requested inside ZPSDS: 0 shadow zone group persistent: 1 shadow zoning enabled: 0 shadow zone group: 1 device slot number: 255 device slot group number: 255 device slot group output connector: =20 Discover response: expander change count: 1328 phy identifier: 6 attached device type: expander device attached reason: SMP phy control requested negotiated logical link rate: phy enabled, 6 Gbps attached initiator: ssp=3D0 stp=3D0 smp=3D0 sata_host=3D0 attached sata port selector: 0 STP buffer too small: 0 attached target: ssp=3D0 stp=3D0 smp=3D1 sata_device=3D0 SAS address: 0x50030480017ae23f attached SAS address: 0x50030480017bd5bf attached phy identifier: 2 attached persistent capable: 0 attached power capable: 0 attached slumber capable: 0 attached partial capable: 0 attached inside ZPSDS persistent: 0 attached requested inside ZPSDS: 0 attached break_reply capable: 1 attached pwr_dis capable: 0 programmed minimum physical link rate: 1.5 Gbps hardware minimum physical link rate: 1.5 Gbps programmed maximum physical link rate: 6 Gbps hardware maximum physical link rate: 6 Gbps phy change count: 4 virtual phy: 0 partial pathway timeout value: 7 us routing attribute: table connector type: No information connector element index: 0 connector physical link: 0 phy power condition: 0 sas power capable: 0 sas slumber capable: 0 sas partial capable: 0 sata slumber capable: 0 sata partial capable: 0 pwr_dis signal: 0 pwr_dis control capable: 0 sas slumber enabled: 0 sas partial enabled: 0 sata slumber enabled: 0 sata partial enabled: 0 attached device name: 0x50030480017bd5bf requested inside ZPSDS changed by expander: 0 inside ZPSDS persistent: 0 requested inside ZPSDS: 0 zone group persistent: 1 inside ZPSDS: 0 zoning enabled: 0 zone group: 1 self-configuration status: 0 self-configuration levels completed: 1 self-configuration sas address: 0x0 programmed phy capabilities: 0x0 current phy capabilities: 0x0 attached phy capabilities: 0x0 reason: unknown negotiated physical link rate: phy enabled, 6 Gbps optical mode enabled: 0 negotiated SSC: 0 hardware muxing supported: 0 default inside ZPSDS persistent: 0 default requested inside ZPSDS: 0 default zone group persistent: 1 default zoning enabled: 0 default zone group: 1 saved inside ZPSDS persistent: 0 saved requested inside ZPSDS: 0 saved zone group persistent: 1 saved zoning enabled: 0 saved zone group: 1 shadow inside ZPSDS persistent: 0 shadow requested inside ZPSDS: 0 shadow zone group persistent: 1 shadow zoning enabled: 0 shadow zone group: 1 device slot number: 255 device slot group number: 255 device slot group output connector: =20 Discover response: expander change count: 1328 phy identifier: 7 attached device type: expander device attached reason: SMP phy control requested negotiated logical link rate: phy enabled, 6 Gbps attached initiator: ssp=3D0 stp=3D0 smp=3D0 sata_host=3D0 attached sata port selector: 0 STP buffer too small: 0 attached target: ssp=3D0 stp=3D0 smp=3D1 sata_device=3D0 SAS address: 0x50030480017ae23f attached SAS address: 0x50030480017bd5bf attached phy identifier: 3 attached persistent capable: 0 attached power capable: 0 attached slumber capable: 0 attached partial capable: 0 attached inside ZPSDS persistent: 0 attached requested inside ZPSDS: 0 attached break_reply capable: 1 attached pwr_dis capable: 0 programmed minimum physical link rate: 1.5 Gbps hardware minimum physical link rate: 1.5 Gbps programmed maximum physical link rate: 6 Gbps hardware maximum physical link rate: 6 Gbps phy change count: 4 virtual phy: 0 partial pathway timeout value: 7 us routing attribute: table connector type: No information connector element index: 0 connector physical link: 0 phy power condition: 0 sas power capable: 0 sas slumber capable: 0 sas partial capable: 0 sata slumber capable: 0 sata partial capable: 0 pwr_dis signal: 0 pwr_dis control capable: 0 sas slumber enabled: 0 sas partial enabled: 0 sata slumber enabled: 0 sata partial enabled: 0 attached device name: 0x50030480017bd5bf requested inside ZPSDS changed by expander: 0 inside ZPSDS persistent: 0 requested inside ZPSDS: 0 zone group persistent: 1 inside ZPSDS: 0 zoning enabled: 0 zone group: 1 self-configuration status: 0 self-configuration levels completed: 1 self-configuration sas address: 0x0 programmed phy capabilities: 0x0 current phy capabilities: 0x0 attached phy capabilities: 0x0 reason: unknown negotiated physical link rate: phy enabled, 6 Gbps optical mode enabled: 0 negotiated SSC: 0 hardware muxing supported: 0 default inside ZPSDS persistent: 0 default requested inside ZPSDS: 0 default zone group persistent: 1 default zoning enabled: 0 default zone group: 1 saved inside ZPSDS persistent: 0 saved requested inside ZPSDS: 0 saved zone group persistent: 1 saved zoning enabled: 0 saved zone group: 1 shadow inside ZPSDS persistent: 0 shadow requested inside ZPSDS: 0 shadow zone group persistent: 1 shadow zoning enabled: 0 shadow zone group: 1 device slot number: 255 device slot group number: 255 device slot group output connector: =20 Discover response: expander change count: 1328 phy identifier: 8 attached device type: no device attached attached reason: unknown negotiated logical link rate: phy enabled; unknown attached initiator: ssp=3D0 stp=3D0 smp=3D0 sata_host=3D0 attached sata port selector: 0 STP buffer too small: 0 attached target: ssp=3D0 stp=3D0 smp=3D0 sata_device=3D0 SAS address: 0x50030480017ae23f attached SAS address: 0x0 attached phy identifier: 0 attached persistent capable: 0 attached power capable: 0 attached slumber capable: 0 attached partial capable: 0 attached inside ZPSDS persistent: 0 attached requested inside ZPSDS: 0 attached break_reply capable: 0 attached pwr_dis capable: 0 programmed minimum physical link rate: 1.5 Gbps hardware minimum physical link rate: 1.5 Gbps programmed maximum physical link rate: 6 Gbps hardware maximum physical link rate: 6 Gbps phy change count: 1 virtual phy: 0 partial pathway timeout value: 7 us routing attribute: table connector type: No information connector element index: 0 connector physical link: 0 phy power condition: 0 sas power capable: 0 sas slumber capable: 0 sas partial capable: 0 sata slumber capable: 0 sata partial capable: 0 pwr_dis signal: 0 pwr_dis control capable: 0 sas slumber enabled: 0 sas partial enabled: 0 sata slumber enabled: 0 sata partial enabled: 0 attached device name: 0x0 requested inside ZPSDS changed by expander: 0 inside ZPSDS persistent: 0 requested inside ZPSDS: 0 zone group persistent: 1 inside ZPSDS: 0 zoning enabled: 0 zone group: 1 self-configuration status: 0 self-configuration levels completed: 0 self-configuration sas address: 0x0 programmed phy capabilities: 0x0 current phy capabilities: 0x0 attached phy capabilities: 0x0 reason: unknown negotiated physical link rate: phy enabled; unknown optical mode enabled: 0 negotiated SSC: 0 hardware muxing supported: 0 default inside ZPSDS persistent: 0 default requested inside ZPSDS: 0 default zone group persistent: 1 default zoning enabled: 0 default zone group: 1 saved inside ZPSDS persistent: 0 saved requested inside ZPSDS: 0 saved zone group persistent: 1 saved zoning enabled: 0 saved zone group: 1 shadow inside ZPSDS persistent: 0 shadow requested inside ZPSDS: 0 shadow zone group persistent: 1 shadow zoning enabled: 0 shadow zone group: 1 device slot number: 255 device slot group number: 255 device slot group output connector: =20 Discover response: expander change count: 1328 phy identifier: 9 attached device type: no device attached attached reason: unknown negotiated logical link rate: phy enabled; unknown attached initiator: ssp=3D0 stp=3D0 smp=3D0 sata_host=3D0 attached sata port selector: 0 STP buffer too small: 0 attached target: ssp=3D0 stp=3D0 smp=3D0 sata_device=3D0 SAS address: 0x50030480017ae23f attached SAS address: 0x0 attached phy identifier: 0 attached persistent capable: 0 attached power capable: 0 attached slumber capable: 0 attached partial capable: 0 attached inside ZPSDS persistent: 0 attached requested inside ZPSDS: 0 attached break_reply capable: 0 attached pwr_dis capable: 0 programmed minimum physical link rate: 1.5 Gbps hardware minimum physical link rate: 1.5 Gbps programmed maximum physical link rate: 6 Gbps hardware maximum physical link rate: 6 Gbps phy change count: 1 virtual phy: 0 partial pathway timeout value: 7 us routing attribute: table connector type: No information connector element index: 0 connector physical link: 0 phy power condition: 0 sas power capable: 0 sas slumber capable: 0 sas partial capable: 0 sata slumber capable: 0 sata partial capable: 0 pwr_dis signal: 0 pwr_dis control capable: 0 sas slumber enabled: 0 sas partial enabled: 0 sata slumber enabled: 0 sata partial enabled: 0 attached device name: 0x0 requested inside ZPSDS changed by expander: 0 inside ZPSDS persistent: 0 requested inside ZPSDS: 0 zone group persistent: 1 inside ZPSDS: 0 zoning enabled: 0 zone group: 1 self-configuration status: 0 self-configuration levels completed: 0 self-configuration sas address: 0x0 programmed phy capabilities: 0x0 current phy capabilities: 0x0 attached phy capabilities: 0x0 reason: unknown negotiated physical link rate: phy enabled; unknown optical mode enabled: 0 negotiated SSC: 0 hardware muxing supported: 0 default inside ZPSDS persistent: 0 default requested inside ZPSDS: 0 default zone group persistent: 1 default zoning enabled: 0 default zone group: 1 saved inside ZPSDS persistent: 0 saved requested inside ZPSDS: 0 saved zone group persistent: 1 saved zoning enabled: 0 saved zone group: 1 shadow inside ZPSDS persistent: 0 shadow requested inside ZPSDS: 0 shadow zone group persistent: 1 shadow zoning enabled: 0 shadow zone group: 1 device slot number: 255 device slot group number: 255 device slot group output connector: =20 Discover response: expander change count: 1328 phy identifier: 10 attached device type: no device attached attached reason: unknown negotiated logical link rate: phy enabled; unknown attached initiator: ssp=3D0 stp=3D0 smp=3D0 sata_host=3D0 attached sata port selector: 0 STP buffer too small: 0 attached target: ssp=3D0 stp=3D0 smp=3D0 sata_device=3D0 SAS address: 0x50030480017ae23f attached SAS address: 0x0 attached phy identifier: 0 attached persistent capable: 0 attached power capable: 0 attached slumber capable: 0 attached partial capable: 0 attached inside ZPSDS persistent: 0 attached requested inside ZPSDS: 0 attached break_reply capable: 0 attached pwr_dis capable: 0 programmed minimum physical link rate: 1.5 Gbps hardware minimum physical link rate: 1.5 Gbps programmed maximum physical link rate: 6 Gbps hardware maximum physical link rate: 6 Gbps phy change count: 1 virtual phy: 0 partial pathway timeout value: 7 us routing attribute: table connector type: No information connector element index: 0 connector physical link: 0 phy power condition: 0 sas power capable: 0 sas slumber capable: 0 sas partial capable: 0 sata slumber capable: 0 sata partial capable: 0 pwr_dis signal: 0 pwr_dis control capable: 0 sas slumber enabled: 0 sas partial enabled: 0 sata slumber enabled: 0 sata partial enabled: 0 attached device name: 0x0 requested inside ZPSDS changed by expander: 0 inside ZPSDS persistent: 0 requested inside ZPSDS: 0 zone group persistent: 1 inside ZPSDS: 0 zoning enabled: 0 zone group: 1 self-configuration status: 0 self-configuration levels completed: 0 self-configuration sas address: 0x0 programmed phy capabilities: 0x0 current phy capabilities: 0x0 attached phy capabilities: 0x0 reason: unknown negotiated physical link rate: phy enabled; unknown optical mode enabled: 0 negotiated SSC: 0 hardware muxing supported: 0 default inside ZPSDS persistent: 0 default requested inside ZPSDS: 0 default zone group persistent: 1 default zoning enabled: 0 default zone group: 1 saved inside ZPSDS persistent: 0 saved requested inside ZPSDS: 0 saved zone group persistent: 1 saved zoning enabled: 0 saved zone group: 1 shadow inside ZPSDS persistent: 0 shadow requested inside ZPSDS: 0 shadow zone group persistent: 1 shadow zoning enabled: 0 shadow zone group: 1 device slot number: 255 device slot group number: 255 device slot group output connector: =20 Discover response: expander change count: 1328 phy identifier: 11 attached device type: no device attached attached reason: unknown negotiated logical link rate: phy enabled; unknown attached initiator: ssp=3D0 stp=3D0 smp=3D0 sata_host=3D0 attached sata port selector: 0 STP buffer too small: 0 attached target: ssp=3D0 stp=3D0 smp=3D0 sata_device=3D0 SAS address: 0x50030480017ae23f attached SAS address: 0x0 attached phy identifier: 0 attached persistent capable: 0 attached power capable: 0 attached slumber capable: 0 attached partial capable: 0 attached inside ZPSDS persistent: 0 attached requested inside ZPSDS: 0 attached break_reply capable: 0 attached pwr_dis capable: 0 programmed minimum physical link rate: 1.5 Gbps hardware minimum physical link rate: 1.5 Gbps programmed maximum physical link rate: 6 Gbps hardware maximum physical link rate: 6 Gbps phy change count: 1 virtual phy: 0 partial pathway timeout value: 7 us routing attribute: table connector type: No information connector element index: 0 connector physical link: 0 phy power condition: 0 sas power capable: 0 sas slumber capable: 0 sas partial capable: 0 sata slumber capable: 0 sata partial capable: 0 pwr_dis signal: 0 pwr_dis control capable: 0 sas slumber enabled: 0 sas partial enabled: 0 sata slumber enabled: 0 sata partial enabled: 0 attached device name: 0x0 requested inside ZPSDS changed by expander: 0 inside ZPSDS persistent: 0 requested inside ZPSDS: 0 zone group persistent: 1 inside ZPSDS: 0 zoning enabled: 0 zone group: 1 self-configuration status: 0 self-configuration levels completed: 0 self-configuration sas address: 0x0 programmed phy capabilities: 0x0 current phy capabilities: 0x0 attached phy capabilities: 0x0 reason: unknown negotiated physical link rate: phy enabled; unknown optical mode enabled: 0 negotiated SSC: 0 hardware muxing supported: 0 default inside ZPSDS persistent: 0 default requested inside ZPSDS: 0 default zone group persistent: 1 default zoning enabled: 0 default zone group: 1 saved inside ZPSDS persistent: 0 saved requested inside ZPSDS: 0 saved zone group persistent: 1 saved zoning enabled: 0 saved zone group: 1 shadow inside ZPSDS persistent: 0 shadow requested inside ZPSDS: 0 shadow zone group persistent: 1 shadow zoning enabled: 0 shadow zone group: 1 device slot number: 255 device slot group number: 255 device slot group output connector: =20 Discover response: expander change count: 1328 phy identifier: 12 attached device type: SAS or SATA device attached reason: unknown negotiated logical link rate: phy enabled, 6 Gbps attached initiator: ssp=3D0 stp=3D0 smp=3D0 sata_host=3D0 attached sata port selector: 0 STP buffer too small: 0 attached target: ssp=3D0 stp=3D0 smp=3D0 sata_device=3D1 SAS address: 0x50030480017ae23f attached SAS address: 0x50030480017ae20c attached phy identifier: 0 attached persistent capable: 0 attached power capable: 0 attached slumber capable: 0 attached partial capable: 0 attached inside ZPSDS persistent: 0 attached requested inside ZPSDS: 0 attached break_reply capable: 0 attached pwr_dis capable: 0 programmed minimum physical link rate: 1.5 Gbps hardware minimum physical link rate: 1.5 Gbps programmed maximum physical link rate: 6 Gbps hardware maximum physical link rate: 6 Gbps phy change count: 49 virtual phy: 0 partial pathway timeout value: 7 us routing attribute: table connector type: SAS Drive backplane receptacle (SFF-8482) [max 2 phys] connector element index: 0 connector physical link: 0 phy power condition: 0 sas power capable: 0 sas slumber capable: 0 sas partial capable: 0 sata slumber capable: 0 sata partial capable: 0 pwr_dis signal: 0 pwr_dis control capable: 0 sas slumber enabled: 0 sas partial enabled: 0 sata slumber enabled: 0 sata partial enabled: 0 attached device name: 0x0 requested inside ZPSDS changed by expander: 0 inside ZPSDS persistent: 0 requested inside ZPSDS: 0 zone group persistent: 1 inside ZPSDS: 0 zoning enabled: 0 zone group: 1 self-configuration status: 0 self-configuration levels completed: 0 self-configuration sas address: 0x0 programmed phy capabilities: 0x0 current phy capabilities: 0x0 attached phy capabilities: 0x0 reason: unknown negotiated physical link rate: phy enabled, 6 Gbps optical mode enabled: 0 negotiated SSC: 0 hardware muxing supported: 0 default inside ZPSDS persistent: 0 default requested inside ZPSDS: 0 default zone group persistent: 1 default zoning enabled: 0 default zone group: 1 saved inside ZPSDS persistent: 0 saved requested inside ZPSDS: 0 saved zone group persistent: 1 saved zoning enabled: 0 saved zone group: 1 shadow inside ZPSDS persistent: 0 shadow requested inside ZPSDS: 0 shadow zone group persistent: 1 shadow zoning enabled: 0 shadow zone group: 1 device slot number: 255 device slot group number: 255 device slot group output connector: =20 Discover response: expander change count: 1328 phy identifier: 13 attached device type: SAS or SATA device attached reason: unknown negotiated logical link rate: phy enabled, 6 Gbps attached initiator: ssp=3D0 stp=3D0 smp=3D0 sata_host=3D0 attached sata port selector: 0 STP buffer too small: 0 attached target: ssp=3D0 stp=3D0 smp=3D0 sata_device=3D1 SAS address: 0x50030480017ae23f attached SAS address: 0x50030480017ae20d attached phy identifier: 0 attached persistent capable: 0 attached power capable: 0 attached slumber capable: 0 attached partial capable: 0 attached inside ZPSDS persistent: 0 attached requested inside ZPSDS: 0 attached break_reply capable: 0 attached pwr_dis capable: 0 programmed minimum physical link rate: 1.5 Gbps hardware minimum physical link rate: 1.5 Gbps programmed maximum physical link rate: 6 Gbps hardware maximum physical link rate: 6 Gbps phy change count: 49 virtual phy: 0 partial pathway timeout value: 7 us routing attribute: table connector type: SAS Drive backplane receptacle (SFF-8482) [max 2 phys] connector element index: 1 connector physical link: 0 phy power condition: 0 sas power capable: 0 sas slumber capable: 0 sas partial capable: 0 sata slumber capable: 0 sata partial capable: 0 pwr_dis signal: 0 pwr_dis control capable: 0 sas slumber enabled: 0 sas partial enabled: 0 sata slumber enabled: 0 sata partial enabled: 0 attached device name: 0x0 requested inside ZPSDS changed by expander: 0 inside ZPSDS persistent: 0 requested inside ZPSDS: 0 zone group persistent: 1 inside ZPSDS: 0 zoning enabled: 0 zone group: 1 self-configuration status: 0 self-configuration levels completed: 0 self-configuration sas address: 0x0 programmed phy capabilities: 0x0 current phy capabilities: 0x0 attached phy capabilities: 0x0 reason: unknown negotiated physical link rate: phy enabled, 6 Gbps optical mode enabled: 0 negotiated SSC: 0 hardware muxing supported: 0 default inside ZPSDS persistent: 0 default requested inside ZPSDS: 0 default zone group persistent: 1 default zoning enabled: 0 default zone group: 1 saved inside ZPSDS persistent: 0 saved requested inside ZPSDS: 0 saved zone group persistent: 1 saved zoning enabled: 0 saved zone group: 1 shadow inside ZPSDS persistent: 0 shadow requested inside ZPSDS: 0 shadow zone group persistent: 1 shadow zoning enabled: 0 shadow zone group: 1 device slot number: 255 device slot group number: 255 device slot group output connector: =20 Discover response: expander change count: 1328 phy identifier: 14 attached device type: SAS or SATA device attached reason: unknown negotiated logical link rate: phy enabled, 6 Gbps attached initiator: ssp=3D0 stp=3D0 smp=3D0 sata_host=3D0 attached sata port selector: 0 STP buffer too small: 0 attached target: ssp=3D0 stp=3D0 smp=3D0 sata_device=3D1 SAS address: 0x50030480017ae23f attached SAS address: 0x50030480017ae20e attached phy identifier: 0 attached persistent capable: 0 attached power capable: 0 attached slumber capable: 0 attached partial capable: 0 attached inside ZPSDS persistent: 0 attached requested inside ZPSDS: 0 attached break_reply capable: 0 attached pwr_dis capable: 0 programmed minimum physical link rate: 1.5 Gbps hardware minimum physical link rate: 1.5 Gbps programmed maximum physical link rate: 6 Gbps hardware maximum physical link rate: 6 Gbps phy change count: 49 virtual phy: 0 partial pathway timeout value: 7 us routing attribute: table connector type: SAS Drive backplane receptacle (SFF-8482) [max 2 phys] connector element index: 2 connector physical link: 0 phy power condition: 0 sas power capable: 0 sas slumber capable: 0 sas partial capable: 0 sata slumber capable: 0 sata partial capable: 0 pwr_dis signal: 0 pwr_dis control capable: 0 sas slumber enabled: 0 sas partial enabled: 0 sata slumber enabled: 0 sata partial enabled: 0 attached device name: 0x0 requested inside ZPSDS changed by expander: 0 inside ZPSDS persistent: 0 requested inside ZPSDS: 0 zone group persistent: 1 inside ZPSDS: 0 zoning enabled: 0 zone group: 1 self-configuration status: 0 self-configuration levels completed: 0 self-configuration sas address: 0x0 programmed phy capabilities: 0x0 current phy capabilities: 0x0 attached phy capabilities: 0x0 reason: unknown negotiated physical link rate: phy enabled, 6 Gbps optical mode enabled: 0 negotiated SSC: 0 hardware muxing supported: 0 default inside ZPSDS persistent: 0 default requested inside ZPSDS: 0 default zone group persistent: 1 default zoning enabled: 0 default zone group: 1 saved inside ZPSDS persistent: 0 saved requested inside ZPSDS: 0 saved zone group persistent: 1 saved zoning enabled: 0 saved zone group: 1 shadow inside ZPSDS persistent: 0 shadow requested inside ZPSDS: 0 shadow zone group persistent: 1 shadow zoning enabled: 0 shadow zone group: 1 device slot number: 255 device slot group number: 255 device slot group output connector: =20 Discover response: expander change count: 1328 phy identifier: 15 attached device type: SAS or SATA device attached reason: unknown negotiated logical link rate: phy enabled, 6 Gbps attached initiator: ssp=3D0 stp=3D0 smp=3D0 sata_host=3D0 attached sata port selector: 0 STP buffer too small: 0 attached target: ssp=3D0 stp=3D0 smp=3D0 sata_device=3D1 SAS address: 0x50030480017ae23f attached SAS address: 0x50030480017ae20f attached phy identifier: 0 attached persistent capable: 0 attached power capable: 0 attached slumber capable: 0 attached partial capable: 0 attached inside ZPSDS persistent: 0 attached requested inside ZPSDS: 0 attached break_reply capable: 0 attached pwr_dis capable: 0 programmed minimum physical link rate: 1.5 Gbps hardware minimum physical link rate: 1.5 Gbps programmed maximum physical link rate: 6 Gbps hardware maximum physical link rate: 6 Gbps phy change count: 49 virtual phy: 0 partial pathway timeout value: 7 us routing attribute: table connector type: SAS Drive backplane receptacle (SFF-8482) [max 2 phys] connector element index: 3 connector physical link: 0 phy power condition: 0 sas power capable: 0 sas slumber capable: 0 sas partial capable: 0 sata slumber capable: 0 sata partial capable: 0 pwr_dis signal: 0 pwr_dis control capable: 0 sas slumber enabled: 0 sas partial enabled: 0 sata slumber enabled: 0 sata partial enabled: 0 attached device name: 0x0 requested inside ZPSDS changed by expander: 0 inside ZPSDS persistent: 0 requested inside ZPSDS: 0 zone group persistent: 1 inside ZPSDS: 0 zoning enabled: 0 zone group: 1 self-configuration status: 0 self-configuration levels completed: 0 self-configuration sas address: 0x0 programmed phy capabilities: 0x0 current phy capabilities: 0x0 attached phy capabilities: 0x0 reason: unknown negotiated physical link rate: phy enabled, 6 Gbps optical mode enabled: 0 negotiated SSC: 0 hardware muxing supported: 0 default inside ZPSDS persistent: 0 default requested inside ZPSDS: 0 default zone group persistent: 1 default zoning enabled: 0 default zone group: 1 saved inside ZPSDS persistent: 0 saved requested inside ZPSDS: 0 saved zone group persistent: 1 saved zoning enabled: 0 saved zone group: 1 shadow inside ZPSDS persistent: 0 shadow requested inside ZPSDS: 0 shadow zone group persistent: 1 shadow zoning enabled: 0 shadow zone group: 1 device slot number: 255 device slot group number: 255 device slot group output connector: =20 Discover response: expander change count: 1328 phy identifier: 16 attached device type: SAS or SATA device attached reason: unknown negotiated logical link rate: phy enabled, 6 Gbps attached initiator: ssp=3D0 stp=3D0 smp=3D0 sata_host=3D0 attached sata port selector: 0 STP buffer too small: 0 attached target: ssp=3D0 stp=3D0 smp=3D0 sata_device=3D1 SAS address: 0x50030480017ae23f attached SAS address: 0x50030480017ae210 attached phy identifier: 0 attached persistent capable: 0 attached power capable: 0 attached slumber capable: 0 attached partial capable: 0 attached inside ZPSDS persistent: 0 attached requested inside ZPSDS: 0 attached break_reply capable: 0 attached pwr_dis capable: 0 programmed minimum physical link rate: 1.5 Gbps hardware minimum physical link rate: 1.5 Gbps programmed maximum physical link rate: 6 Gbps hardware maximum physical link rate: 6 Gbps phy change count: 49 virtual phy: 0 partial pathway timeout value: 7 us routing attribute: table connector type: SAS Drive backplane receptacle (SFF-8482) [max 2 phys] connector element index: 4 connector physical link: 0 phy power condition: 0 sas power capable: 0 sas slumber capable: 0 sas partial capable: 0 sata slumber capable: 0 sata partial capable: 0 pwr_dis signal: 0 pwr_dis control capable: 0 sas slumber enabled: 0 sas partial enabled: 0 sata slumber enabled: 0 sata partial enabled: 0 attached device name: 0x0 requested inside ZPSDS changed by expander: 0 inside ZPSDS persistent: 0 requested inside ZPSDS: 0 zone group persistent: 1 inside ZPSDS: 0 zoning enabled: 0 zone group: 1 self-configuration status: 0 self-configuration levels completed: 0 self-configuration sas address: 0x0 programmed phy capabilities: 0x0 current phy capabilities: 0x0 attached phy capabilities: 0x0 reason: unknown negotiated physical link rate: phy enabled, 6 Gbps optical mode enabled: 0 negotiated SSC: 0 hardware muxing supported: 0 default inside ZPSDS persistent: 0 default requested inside ZPSDS: 0 default zone group persistent: 1 default zoning enabled: 0 default zone group: 1 saved inside ZPSDS persistent: 0 saved requested inside ZPSDS: 0 saved zone group persistent: 1 saved zoning enabled: 0 saved zone group: 1 shadow inside ZPSDS persistent: 0 shadow requested inside ZPSDS: 0 shadow zone group persistent: 1 shadow zoning enabled: 0 shadow zone group: 1 device slot number: 255 device slot group number: 255 device slot group output connector: =20 Discover response: expander change count: 1328 phy identifier: 17 attached device type: SAS or SATA device attached reason: unknown negotiated logical link rate: phy enabled, 6 Gbps attached initiator: ssp=3D0 stp=3D0 smp=3D0 sata_host=3D0 attached sata port selector: 0 STP buffer too small: 0 attached target: ssp=3D0 stp=3D0 smp=3D0 sata_device=3D1 SAS address: 0x50030480017ae23f attached SAS address: 0x50030480017ae211 attached phy identifier: 0 attached persistent capable: 0 attached power capable: 0 attached slumber capable: 0 attached partial capable: 0 attached inside ZPSDS persistent: 0 attached requested inside ZPSDS: 0 attached break_reply capable: 0 attached pwr_dis capable: 0 programmed minimum physical link rate: 1.5 Gbps hardware minimum physical link rate: 1.5 Gbps programmed maximum physical link rate: 6 Gbps hardware maximum physical link rate: 6 Gbps phy change count: 48 virtual phy: 0 partial pathway timeout value: 7 us routing attribute: table connector type: SAS Drive backplane receptacle (SFF-8482) [max 2 phys] connector element index: 5 connector physical link: 0 phy power condition: 0 sas power capable: 0 sas slumber capable: 0 sas partial capable: 0 sata slumber capable: 0 sata partial capable: 0 pwr_dis signal: 0 pwr_dis control capable: 0 sas slumber enabled: 0 sas partial enabled: 0 sata slumber enabled: 0 sata partial enabled: 0 attached device name: 0x0 requested inside ZPSDS changed by expander: 0 inside ZPSDS persistent: 0 requested inside ZPSDS: 0 zone group persistent: 1 inside ZPSDS: 0 zoning enabled: 0 zone group: 1 self-configuration status: 0 self-configuration levels completed: 0 self-configuration sas address: 0x0 programmed phy capabilities: 0x0 current phy capabilities: 0x0 attached phy capabilities: 0x0 reason: unknown negotiated physical link rate: phy enabled, 6 Gbps optical mode enabled: 0 negotiated SSC: 0 hardware muxing supported: 0 default inside ZPSDS persistent: 0 default requested inside ZPSDS: 0 default zone group persistent: 1 default zoning enabled: 0 default zone group: 1 saved inside ZPSDS persistent: 0 saved requested inside ZPSDS: 0 saved zone group persistent: 1 saved zoning enabled: 0 saved zone group: 1 shadow inside ZPSDS persistent: 0 shadow requested inside ZPSDS: 0 shadow zone group persistent: 1 shadow zoning enabled: 0 shadow zone group: 1 device slot number: 255 device slot group number: 255 device slot group output connector: =20 Discover response: expander change count: 1328 phy identifier: 18 attached device type: SAS or SATA device attached reason: unknown negotiated logical link rate: phy enabled, 6 Gbps attached initiator: ssp=3D0 stp=3D0 smp=3D0 sata_host=3D0 attached sata port selector: 0 STP buffer too small: 0 attached target: ssp=3D0 stp=3D0 smp=3D0 sata_device=3D1 SAS address: 0x50030480017ae23f attached SAS address: 0x50030480017ae212 attached phy identifier: 0 attached persistent capable: 0 attached power capable: 0 attached slumber capable: 0 attached partial capable: 0 attached inside ZPSDS persistent: 0 attached requested inside ZPSDS: 0 attached break_reply capable: 0 attached pwr_dis capable: 0 programmed minimum physical link rate: 1.5 Gbps hardware minimum physical link rate: 1.5 Gbps programmed maximum physical link rate: 6 Gbps hardware maximum physical link rate: 6 Gbps phy change count: 48 virtual phy: 0 partial pathway timeout value: 7 us routing attribute: table connector type: SAS Drive backplane receptacle (SFF-8482) [max 2 phys] connector element index: 6 connector physical link: 0 phy power condition: 0 sas power capable: 0 sas slumber capable: 0 sas partial capable: 0 sata slumber capable: 0 sata partial capable: 0 pwr_dis signal: 0 pwr_dis control capable: 0 sas slumber enabled: 0 sas partial enabled: 0 sata slumber enabled: 0 sata partial enabled: 0 attached device name: 0x0 requested inside ZPSDS changed by expander: 0 inside ZPSDS persistent: 0 requested inside ZPSDS: 0 zone group persistent: 1 inside ZPSDS: 0 zoning enabled: 0 zone group: 1 self-configuration status: 0 self-configuration levels completed: 0 self-configuration sas address: 0x0 programmed phy capabilities: 0x0 current phy capabilities: 0x0 attached phy capabilities: 0x0 reason: unknown negotiated physical link rate: phy enabled, 6 Gbps optical mode enabled: 0 negotiated SSC: 0 hardware muxing supported: 0 default inside ZPSDS persistent: 0 default requested inside ZPSDS: 0 default zone group persistent: 1 default zoning enabled: 0 default zone group: 1 saved inside ZPSDS persistent: 0 saved requested inside ZPSDS: 0 saved zone group persistent: 1 saved zoning enabled: 0 saved zone group: 1 shadow inside ZPSDS persistent: 0 shadow requested inside ZPSDS: 0 shadow zone group persistent: 1 shadow zoning enabled: 0 shadow zone group: 1 device slot number: 255 device slot group number: 255 device slot group output connector: =20 Discover response: expander change count: 1328 phy identifier: 19 attached device type: SAS or SATA device attached reason: unknown negotiated logical link rate: phy enabled, 6 Gbps attached initiator: ssp=3D0 stp=3D0 smp=3D0 sata_host=3D0 attached sata port selector: 0 STP buffer too small: 0 attached target: ssp=3D0 stp=3D0 smp=3D0 sata_device=3D1 SAS address: 0x50030480017ae23f attached SAS address: 0x50030480017ae213 attached phy identifier: 0 attached persistent capable: 0 attached power capable: 0 attached slumber capable: 0 attached partial capable: 0 attached inside ZPSDS persistent: 0 attached requested inside ZPSDS: 0 attached break_reply capable: 0 attached pwr_dis capable: 0 programmed minimum physical link rate: 1.5 Gbps hardware minimum physical link rate: 1.5 Gbps programmed maximum physical link rate: 6 Gbps hardware maximum physical link rate: 6 Gbps phy change count: 49 virtual phy: 0 partial pathway timeout value: 7 us routing attribute: table connector type: SAS Drive backplane receptacle (SFF-8482) [max 2 phys] connector element index: 7 connector physical link: 0 phy power condition: 0 sas power capable: 0 sas slumber capable: 0 sas partial capable: 0 sata slumber capable: 0 sata partial capable: 0 pwr_dis signal: 0 pwr_dis control capable: 0 sas slumber enabled: 0 sas partial enabled: 0 sata slumber enabled: 0 sata partial enabled: 0 attached device name: 0x0 requested inside ZPSDS changed by expander: 0 inside ZPSDS persistent: 0 requested inside ZPSDS: 0 zone group persistent: 1 inside ZPSDS: 0 zoning enabled: 0 zone group: 1 self-configuration status: 0 self-configuration levels completed: 0 self-configuration sas address: 0x0 programmed phy capabilities: 0x0 current phy capabilities: 0x0 attached phy capabilities: 0x0 reason: unknown negotiated physical link rate: phy enabled, 6 Gbps optical mode enabled: 0 negotiated SSC: 0 hardware muxing supported: 0 default inside ZPSDS persistent: 0 default requested inside ZPSDS: 0 default zone group persistent: 1 default zoning enabled: 0 default zone group: 1 saved inside ZPSDS persistent: 0 saved requested inside ZPSDS: 0 saved zone group persistent: 1 saved zoning enabled: 0 saved zone group: 1 shadow inside ZPSDS persistent: 0 shadow requested inside ZPSDS: 0 shadow zone group persistent: 1 shadow zoning enabled: 0 shadow zone group: 1 device slot number: 255 device slot group number: 255 device slot group output connector: =20 Discover response: expander change count: 1328 phy identifier: 20 attached device type: SAS or SATA device attached reason: unknown negotiated logical link rate: phy enabled, 6 Gbps attached initiator: ssp=3D0 stp=3D0 smp=3D0 sata_host=3D0 attached sata port selector: 0 STP buffer too small: 0 attached target: ssp=3D0 stp=3D0 smp=3D0 sata_device=3D1 SAS address: 0x50030480017ae23f attached SAS address: 0x50030480017ae214 attached phy identifier: 0 attached persistent capable: 0 attached power capable: 0 attached slumber capable: 0 attached partial capable: 0 attached inside ZPSDS persistent: 0 attached requested inside ZPSDS: 0 attached break_reply capable: 0 attached pwr_dis capable: 0 programmed minimum physical link rate: 1.5 Gbps hardware minimum physical link rate: 1.5 Gbps programmed maximum physical link rate: 6 Gbps hardware maximum physical link rate: 6 Gbps phy change count: 48 virtual phy: 0 partial pathway timeout value: 7 us routing attribute: table connector type: SAS Drive backplane receptacle (SFF-8482) [max 2 phys] connector element index: 8 connector physical link: 0 phy power condition: 0 sas power capable: 0 sas slumber capable: 0 sas partial capable: 0 sata slumber capable: 0 sata partial capable: 0 pwr_dis signal: 0 pwr_dis control capable: 0 sas slumber enabled: 0 sas partial enabled: 0 sata slumber enabled: 0 sata partial enabled: 0 attached device name: 0x0 requested inside ZPSDS changed by expander: 0 inside ZPSDS persistent: 0 requested inside ZPSDS: 0 zone group persistent: 1 inside ZPSDS: 0 zoning enabled: 0 zone group: 1 self-configuration status: 0 self-configuration levels completed: 0 self-configuration sas address: 0x0 programmed phy capabilities: 0x0 current phy capabilities: 0x0 attached phy capabilities: 0x0 reason: unknown negotiated physical link rate: phy enabled, 6 Gbps optical mode enabled: 0 negotiated SSC: 0 hardware muxing supported: 0 default inside ZPSDS persistent: 0 default requested inside ZPSDS: 0 default zone group persistent: 1 default zoning enabled: 0 default zone group: 1 saved inside ZPSDS persistent: 0 saved requested inside ZPSDS: 0 saved zone group persistent: 1 saved zoning enabled: 0 saved zone group: 1 shadow inside ZPSDS persistent: 0 shadow requested inside ZPSDS: 0 shadow zone group persistent: 1 shadow zoning enabled: 0 shadow zone group: 1 device slot number: 255 device slot group number: 255 device slot group output connector: =20 Discover response: expander change count: 1328 phy identifier: 21 attached device type: SAS or SATA device attached reason: unknown negotiated logical link rate: phy enabled, 6 Gbps attached initiator: ssp=3D0 stp=3D0 smp=3D0 sata_host=3D0 attached sata port selector: 0 STP buffer too small: 0 attached target: ssp=3D0 stp=3D0 smp=3D0 sata_device=3D1 SAS address: 0x50030480017ae23f attached SAS address: 0x50030480017ae215 attached phy identifier: 0 attached persistent capable: 0 attached power capable: 0 attached slumber capable: 0 attached partial capable: 0 attached inside ZPSDS persistent: 0 attached requested inside ZPSDS: 0 attached break_reply capable: 0 attached pwr_dis capable: 0 programmed minimum physical link rate: 1.5 Gbps hardware minimum physical link rate: 1.5 Gbps programmed maximum physical link rate: 6 Gbps hardware maximum physical link rate: 6 Gbps phy change count: 48 virtual phy: 0 partial pathway timeout value: 7 us routing attribute: table connector type: SAS Drive backplane receptacle (SFF-8482) [max 2 phys] connector element index: 9 connector physical link: 0 phy power condition: 0 sas power capable: 0 sas slumber capable: 0 sas partial capable: 0 sata slumber capable: 0 sata partial capable: 0 pwr_dis signal: 0 pwr_dis control capable: 0 sas slumber enabled: 0 sas partial enabled: 0 sata slumber enabled: 0 sata partial enabled: 0 attached device name: 0x0 requested inside ZPSDS changed by expander: 0 inside ZPSDS persistent: 0 requested inside ZPSDS: 0 zone group persistent: 1 inside ZPSDS: 0 zoning enabled: 0 zone group: 1 self-configuration status: 0 self-configuration levels completed: 0 self-configuration sas address: 0x0 programmed phy capabilities: 0x0 current phy capabilities: 0x0 attached phy capabilities: 0x0 reason: unknown negotiated physical link rate: phy enabled, 6 Gbps optical mode enabled: 0 negotiated SSC: 0 hardware muxing supported: 0 default inside ZPSDS persistent: 0 default requested inside ZPSDS: 0 default zone group persistent: 1 default zoning enabled: 0 default zone group: 1 saved inside ZPSDS persistent: 0 saved requested inside ZPSDS: 0 saved zone group persistent: 1 saved zoning enabled: 0 saved zone group: 1 shadow inside ZPSDS persistent: 0 shadow requested inside ZPSDS: 0 shadow zone group persistent: 1 shadow zoning enabled: 0 shadow zone group: 1 device slot number: 255 device slot group number: 255 device slot group output connector: =20 Discover response: expander change count: 1328 phy identifier: 22 attached device type: SAS or SATA device attached reason: unknown negotiated logical link rate: phy enabled, 6 Gbps attached initiator: ssp=3D0 stp=3D0 smp=3D0 sata_host=3D0 attached sata port selector: 0 STP buffer too small: 0 attached target: ssp=3D0 stp=3D0 smp=3D0 sata_device=3D1 SAS address: 0x50030480017ae23f attached SAS address: 0x50030480017ae216 attached phy identifier: 0 attached persistent capable: 0 attached power capable: 0 attached slumber capable: 0 attached partial capable: 0 attached inside ZPSDS persistent: 0 attached requested inside ZPSDS: 0 attached break_reply capable: 0 attached pwr_dis capable: 0 programmed minimum physical link rate: 1.5 Gbps hardware minimum physical link rate: 1.5 Gbps programmed maximum physical link rate: 6 Gbps hardware maximum physical link rate: 6 Gbps phy change count: 48 virtual phy: 0 partial pathway timeout value: 7 us routing attribute: table connector type: SAS Drive backplane receptacle (SFF-8482) [max 2 phys] connector element index: 10 connector physical link: 0 phy power condition: 0 sas power capable: 0 sas slumber capable: 0 sas partial capable: 0 sata slumber capable: 0 sata partial capable: 0 pwr_dis signal: 0 pwr_dis control capable: 0 sas slumber enabled: 0 sas partial enabled: 0 sata slumber enabled: 0 sata partial enabled: 0 attached device name: 0x0 requested inside ZPSDS changed by expander: 0 inside ZPSDS persistent: 0 requested inside ZPSDS: 0 zone group persistent: 1 inside ZPSDS: 0 zoning enabled: 0 zone group: 1 self-configuration status: 0 self-configuration levels completed: 0 self-configuration sas address: 0x0 programmed phy capabilities: 0x0 current phy capabilities: 0x0 attached phy capabilities: 0x0 reason: unknown negotiated physical link rate: phy enabled, 6 Gbps optical mode enabled: 0 negotiated SSC: 0 hardware muxing supported: 0 default inside ZPSDS persistent: 0 default requested inside ZPSDS: 0 default zone group persistent: 1 default zoning enabled: 0 default zone group: 1 saved inside ZPSDS persistent: 0 saved requested inside ZPSDS: 0 saved zone group persistent: 1 saved zoning enabled: 0 saved zone group: 1 shadow inside ZPSDS persistent: 0 shadow requested inside ZPSDS: 0 shadow zone group persistent: 1 shadow zoning enabled: 0 shadow zone group: 1 device slot number: 255 device slot group number: 255 device slot group output connector: =20 Discover response: expander change count: 1328 phy identifier: 23 attached device type: SAS or SATA device attached reason: unknown negotiated logical link rate: phy enabled, 6 Gbps attached initiator: ssp=3D0 stp=3D0 smp=3D0 sata_host=3D0 attached sata port selector: 0 STP buffer too small: 0 attached target: ssp=3D0 stp=3D0 smp=3D0 sata_device=3D1 SAS address: 0x50030480017ae23f attached SAS address: 0x50030480017ae217 attached phy identifier: 0 attached persistent capable: 0 attached power capable: 0 attached slumber capable: 0 attached partial capable: 0 attached inside ZPSDS persistent: 0 attached requested inside ZPSDS: 0 attached break_reply capable: 0 attached pwr_dis capable: 0 programmed minimum physical link rate: 1.5 Gbps hardware minimum physical link rate: 1.5 Gbps programmed maximum physical link rate: 6 Gbps hardware maximum physical link rate: 6 Gbps phy change count: 49 virtual phy: 0 partial pathway timeout value: 7 us routing attribute: table connector type: SAS Drive backplane receptacle (SFF-8482) [max 2 phys] connector element index: 11 connector physical link: 0 phy power condition: 0 sas power capable: 0 sas slumber capable: 0 sas partial capable: 0 sata slumber capable: 0 sata partial capable: 0 pwr_dis signal: 0 pwr_dis control capable: 0 sas slumber enabled: 0 sas partial enabled: 0 sata slumber enabled: 0 sata partial enabled: 0 attached device name: 0x0 requested inside ZPSDS changed by expander: 0 inside ZPSDS persistent: 0 requested inside ZPSDS: 0 zone group persistent: 1 inside ZPSDS: 0 zoning enabled: 0 zone group: 1 self-configuration status: 0 self-configuration levels completed: 0 self-configuration sas address: 0x0 programmed phy capabilities: 0x0 current phy capabilities: 0x0 attached phy capabilities: 0x0 reason: unknown negotiated physical link rate: phy enabled, 6 Gbps optical mode enabled: 0 negotiated SSC: 0 hardware muxing supported: 0 default inside ZPSDS persistent: 0 default requested inside ZPSDS: 0 default zone group persistent: 1 default zoning enabled: 0 default zone group: 1 saved inside ZPSDS persistent: 0 saved requested inside ZPSDS: 0 saved zone group persistent: 1 saved zoning enabled: 0 saved zone group: 1 shadow inside ZPSDS persistent: 0 shadow requested inside ZPSDS: 0 shadow zone group persistent: 1 shadow zoning enabled: 0 shadow zone group: 1 device slot number: 255 device slot group number: 255 device slot group output connector: =20 Discover response: expander change count: 1328 phy identifier: 24 attached device type: SAS or SATA device attached reason: unknown negotiated logical link rate: phy enabled, 6 Gbps attached initiator: ssp=3D0 stp=3D0 smp=3D0 sata_host=3D0 attached sata port selector: 0 STP buffer too small: 0 attached target: ssp=3D0 stp=3D0 smp=3D0 sata_device=3D1 SAS address: 0x50030480017ae23f attached SAS address: 0x50030480017ae218 attached phy identifier: 0 attached persistent capable: 0 attached power capable: 0 attached slumber capable: 0 attached partial capable: 0 attached inside ZPSDS persistent: 0 attached requested inside ZPSDS: 0 attached break_reply capable: 0 attached pwr_dis capable: 0 programmed minimum physical link rate: 1.5 Gbps hardware minimum physical link rate: 1.5 Gbps programmed maximum physical link rate: 6 Gbps hardware maximum physical link rate: 6 Gbps phy change count: 48 virtual phy: 0 partial pathway timeout value: 7 us routing attribute: table connector type: SAS Drive backplane receptacle (SFF-8482) [max 2 phys] connector element index: 12 connector physical link: 0 phy power condition: 0 sas power capable: 0 sas slumber capable: 0 sas partial capable: 0 sata slumber capable: 0 sata partial capable: 0 pwr_dis signal: 0 pwr_dis control capable: 0 sas slumber enabled: 0 sas partial enabled: 0 sata slumber enabled: 0 sata partial enabled: 0 attached device name: 0x0 requested inside ZPSDS changed by expander: 0 inside ZPSDS persistent: 0 requested inside ZPSDS: 0 zone group persistent: 1 inside ZPSDS: 0 zoning enabled: 0 zone group: 1 self-configuration status: 0 self-configuration levels completed: 0 self-configuration sas address: 0x0 programmed phy capabilities: 0x0 current phy capabilities: 0x0 attached phy capabilities: 0x0 reason: unknown negotiated physical link rate: phy enabled, 6 Gbps optical mode enabled: 0 negotiated SSC: 0 hardware muxing supported: 0 default inside ZPSDS persistent: 0 default requested inside ZPSDS: 0 default zone group persistent: 1 default zoning enabled: 0 default zone group: 1 saved inside ZPSDS persistent: 0 saved requested inside ZPSDS: 0 saved zone group persistent: 1 saved zoning enabled: 0 saved zone group: 1 shadow inside ZPSDS persistent: 0 shadow requested inside ZPSDS: 0 shadow zone group persistent: 1 shadow zoning enabled: 0 shadow zone group: 1 device slot number: 255 device slot group number: 255 device slot group output connector: =20 Discover response: expander change count: 1328 phy identifier: 25 attached device type: SAS or SATA device attached reason: unknown negotiated logical link rate: phy enabled, 6 Gbps attached initiator: ssp=3D0 stp=3D0 smp=3D0 sata_host=3D0 attached sata port selector: 0 STP buffer too small: 0 attached target: ssp=3D0 stp=3D0 smp=3D0 sata_device=3D1 SAS address: 0x50030480017ae23f attached SAS address: 0x50030480017ae219 attached phy identifier: 0 attached persistent capable: 0 attached power capable: 0 attached slumber capable: 0 attached partial capable: 0 attached inside ZPSDS persistent: 0 attached requested inside ZPSDS: 0 attached break_reply capable: 0 attached pwr_dis capable: 0 programmed minimum physical link rate: 1.5 Gbps hardware minimum physical link rate: 1.5 Gbps programmed maximum physical link rate: 6 Gbps hardware maximum physical link rate: 6 Gbps phy change count: 48 virtual phy: 0 partial pathway timeout value: 7 us routing attribute: table connector type: SAS Drive backplane receptacle (SFF-8482) [max 2 phys] connector element index: 13 connector physical link: 0 phy power condition: 0 sas power capable: 0 sas slumber capable: 0 sas partial capable: 0 sata slumber capable: 0 sata partial capable: 0 pwr_dis signal: 0 pwr_dis control capable: 0 sas slumber enabled: 0 sas partial enabled: 0 sata slumber enabled: 0 sata partial enabled: 0 attached device name: 0x0 requested inside ZPSDS changed by expander: 0 inside ZPSDS persistent: 0 requested inside ZPSDS: 0 zone group persistent: 1 inside ZPSDS: 0 zoning enabled: 0 zone group: 1 self-configuration status: 0 self-configuration levels completed: 0 self-configuration sas address: 0x0 programmed phy capabilities: 0x0 current phy capabilities: 0x0 attached phy capabilities: 0x0 reason: unknown negotiated physical link rate: phy enabled, 6 Gbps optical mode enabled: 0 negotiated SSC: 0 hardware muxing supported: 0 default inside ZPSDS persistent: 0 default requested inside ZPSDS: 0 default zone group persistent: 1 default zoning enabled: 0 default zone group: 1 saved inside ZPSDS persistent: 0 saved requested inside ZPSDS: 0 saved zone group persistent: 1 saved zoning enabled: 0 saved zone group: 1 shadow inside ZPSDS persistent: 0 shadow requested inside ZPSDS: 0 shadow zone group persistent: 1 shadow zoning enabled: 0 shadow zone group: 1 device slot number: 255 device slot group number: 255 device slot group output connector: =20 Discover response: expander change count: 1328 phy identifier: 26 attached device type: SAS or SATA device attached reason: unknown negotiated logical link rate: phy enabled, 6 Gbps attached initiator: ssp=3D0 stp=3D0 smp=3D0 sata_host=3D0 attached sata port selector: 0 STP buffer too small: 0 attached target: ssp=3D0 stp=3D0 smp=3D0 sata_device=3D1 SAS address: 0x50030480017ae23f attached SAS address: 0x50030480017ae21a attached phy identifier: 0 attached persistent capable: 0 attached power capable: 0 attached slumber capable: 0 attached partial capable: 0 attached inside ZPSDS persistent: 0 attached requested inside ZPSDS: 0 attached break_reply capable: 0 attached pwr_dis capable: 0 programmed minimum physical link rate: 1.5 Gbps hardware minimum physical link rate: 1.5 Gbps programmed maximum physical link rate: 6 Gbps hardware maximum physical link rate: 6 Gbps phy change count: 48 virtual phy: 0 partial pathway timeout value: 7 us routing attribute: table connector type: SAS Drive backplane receptacle (SFF-8482) [max 2 phys] connector element index: 14 connector physical link: 0 phy power condition: 0 sas power capable: 0 sas slumber capable: 0 sas partial capable: 0 sata slumber capable: 0 sata partial capable: 0 pwr_dis signal: 0 pwr_dis control capable: 0 sas slumber enabled: 0 sas partial enabled: 0 sata slumber enabled: 0 sata partial enabled: 0 attached device name: 0x0 requested inside ZPSDS changed by expander: 0 inside ZPSDS persistent: 0 requested inside ZPSDS: 0 zone group persistent: 1 inside ZPSDS: 0 zoning enabled: 0 zone group: 1 self-configuration status: 0 self-configuration levels completed: 0 self-configuration sas address: 0x0 programmed phy capabilities: 0x0 current phy capabilities: 0x0 attached phy capabilities: 0x0 reason: unknown negotiated physical link rate: phy enabled, 6 Gbps optical mode enabled: 0 negotiated SSC: 0 hardware muxing supported: 0 default inside ZPSDS persistent: 0 default requested inside ZPSDS: 0 default zone group persistent: 1 default zoning enabled: 0 default zone group: 1 saved inside ZPSDS persistent: 0 saved requested inside ZPSDS: 0 saved zone group persistent: 1 saved zoning enabled: 0 saved zone group: 1 shadow inside ZPSDS persistent: 0 shadow requested inside ZPSDS: 0 shadow zone group persistent: 1 shadow zoning enabled: 0 shadow zone group: 1 device slot number: 255 device slot group number: 255 device slot group output connector: =20 Discover response: expander change count: 1328 phy identifier: 27 attached device type: SAS or SATA device attached reason: unknown negotiated logical link rate: phy enabled, 6 Gbps attached initiator: ssp=3D0 stp=3D0 smp=3D0 sata_host=3D0 attached sata port selector: 0 STP buffer too small: 0 attached target: ssp=3D0 stp=3D0 smp=3D0 sata_device=3D1 SAS address: 0x50030480017ae23f attached SAS address: 0x50030480017ae21b attached phy identifier: 0 attached persistent capable: 0 attached power capable: 0 attached slumber capable: 0 attached partial capable: 0 attached inside ZPSDS persistent: 0 attached requested inside ZPSDS: 0 attached break_reply capable: 0 attached pwr_dis capable: 0 programmed minimum physical link rate: 1.5 Gbps hardware minimum physical link rate: 1.5 Gbps programmed maximum physical link rate: 6 Gbps hardware maximum physical link rate: 6 Gbps phy change count: 49 virtual phy: 0 partial pathway timeout value: 7 us routing attribute: table connector type: SAS Drive backplane receptacle (SFF-8482) [max 2 phys] connector element index: 15 connector physical link: 0 phy power condition: 0 sas power capable: 0 sas slumber capable: 0 sas partial capable: 0 sata slumber capable: 0 sata partial capable: 0 pwr_dis signal: 0 pwr_dis control capable: 0 sas slumber enabled: 0 sas partial enabled: 0 sata slumber enabled: 0 sata partial enabled: 0 attached device name: 0x0 requested inside ZPSDS changed by expander: 0 inside ZPSDS persistent: 0 requested inside ZPSDS: 0 zone group persistent: 1 inside ZPSDS: 0 zoning enabled: 0 zone group: 1 self-configuration status: 0 self-configuration levels completed: 0 self-configuration sas address: 0x0 programmed phy capabilities: 0x0 current phy capabilities: 0x0 attached phy capabilities: 0x0 reason: unknown negotiated physical link rate: phy enabled, 6 Gbps optical mode enabled: 0 negotiated SSC: 0 hardware muxing supported: 0 default inside ZPSDS persistent: 0 default requested inside ZPSDS: 0 default zone group persistent: 1 default zoning enabled: 0 default zone group: 1 saved inside ZPSDS persistent: 0 saved requested inside ZPSDS: 0 saved zone group persistent: 1 saved zoning enabled: 0 saved zone group: 1 shadow inside ZPSDS persistent: 0 shadow requested inside ZPSDS: 0 shadow zone group persistent: 1 shadow zoning enabled: 0 shadow zone group: 1 device slot number: 255 device slot group number: 255 device slot group output connector: =20 Discover response: expander change count: 1328 phy identifier: 28 attached device type: SAS or SATA device attached reason: unknown negotiated logical link rate: phy enabled, 6 Gbps attached initiator: ssp=3D0 stp=3D0 smp=3D0 sata_host=3D0 attached sata port selector: 0 STP buffer too small: 0 attached target: ssp=3D0 stp=3D0 smp=3D0 sata_device=3D1 SAS address: 0x50030480017ae23f attached SAS address: 0x50030480017ae21c attached phy identifier: 0 attached persistent capable: 0 attached power capable: 0 attached slumber capable: 0 attached partial capable: 0 attached inside ZPSDS persistent: 0 attached requested inside ZPSDS: 0 attached break_reply capable: 0 attached pwr_dis capable: 0 programmed minimum physical link rate: 1.5 Gbps hardware minimum physical link rate: 1.5 Gbps programmed maximum physical link rate: 6 Gbps hardware maximum physical link rate: 6 Gbps phy change count: 45 virtual phy: 0 partial pathway timeout value: 7 us routing attribute: table connector type: SAS Drive backplane receptacle (SFF-8482) [max 2 phys] connector element index: 16 connector physical link: 0 phy power condition: 0 sas power capable: 0 sas slumber capable: 0 sas partial capable: 0 sata slumber capable: 0 sata partial capable: 0 pwr_dis signal: 0 pwr_dis control capable: 0 sas slumber enabled: 0 sas partial enabled: 0 sata slumber enabled: 0 sata partial enabled: 0 attached device name: 0x0 requested inside ZPSDS changed by expander: 0 inside ZPSDS persistent: 0 requested inside ZPSDS: 0 zone group persistent: 1 inside ZPSDS: 0 zoning enabled: 0 zone group: 1 self-configuration status: 0 self-configuration levels completed: 0 self-configuration sas address: 0x0 programmed phy capabilities: 0x0 current phy capabilities: 0x0 attached phy capabilities: 0x0 reason: unknown negotiated physical link rate: phy enabled, 6 Gbps optical mode enabled: 0 negotiated SSC: 0 hardware muxing supported: 0 default inside ZPSDS persistent: 0 default requested inside ZPSDS: 0 default zone group persistent: 1 default zoning enabled: 0 default zone group: 1 saved inside ZPSDS persistent: 0 saved requested inside ZPSDS: 0 saved zone group persistent: 1 saved zoning enabled: 0 saved zone group: 1 shadow inside ZPSDS persistent: 0 shadow requested inside ZPSDS: 0 shadow zone group persistent: 1 shadow zoning enabled: 0 shadow zone group: 1 device slot number: 255 device slot group number: 255 device slot group output connector: =20 Discover response: expander change count: 1328 phy identifier: 29 attached device type: SAS or SATA device attached reason: unknown negotiated logical link rate: phy enabled, 6 Gbps attached initiator: ssp=3D0 stp=3D0 smp=3D0 sata_host=3D0 attached sata port selector: 0 STP buffer too small: 0 attached target: ssp=3D0 stp=3D0 smp=3D0 sata_device=3D1 SAS address: 0x50030480017ae23f attached SAS address: 0x50030480017ae21d attached phy identifier: 0 attached persistent capable: 0 attached power capable: 0 attached slumber capable: 0 attached partial capable: 0 attached inside ZPSDS persistent: 0 attached requested inside ZPSDS: 0 attached break_reply capable: 0 attached pwr_dis capable: 0 programmed minimum physical link rate: 1.5 Gbps hardware minimum physical link rate: 1.5 Gbps programmed maximum physical link rate: 6 Gbps hardware maximum physical link rate: 6 Gbps phy change count: 45 virtual phy: 0 partial pathway timeout value: 7 us routing attribute: table connector type: SAS Drive backplane receptacle (SFF-8482) [max 2 phys] connector element index: 17 connector physical link: 0 phy power condition: 0 sas power capable: 0 sas slumber capable: 0 sas partial capable: 0 sata slumber capable: 0 sata partial capable: 0 pwr_dis signal: 0 pwr_dis control capable: 0 sas slumber enabled: 0 sas partial enabled: 0 sata slumber enabled: 0 sata partial enabled: 0 attached device name: 0x0 requested inside ZPSDS changed by expander: 0 inside ZPSDS persistent: 0 requested inside ZPSDS: 0 zone group persistent: 1 inside ZPSDS: 0 zoning enabled: 0 zone group: 1 self-configuration status: 0 self-configuration levels completed: 0 self-configuration sas address: 0x0 programmed phy capabilities: 0x0 current phy capabilities: 0x0 attached phy capabilities: 0x0 reason: unknown negotiated physical link rate: phy enabled, 6 Gbps optical mode enabled: 0 negotiated SSC: 0 hardware muxing supported: 0 default inside ZPSDS persistent: 0 default requested inside ZPSDS: 0 default zone group persistent: 1 default zoning enabled: 0 default zone group: 1 saved inside ZPSDS persistent: 0 saved requested inside ZPSDS: 0 saved zone group persistent: 1 saved zoning enabled: 0 saved zone group: 1 shadow inside ZPSDS persistent: 0 shadow requested inside ZPSDS: 0 shadow zone group persistent: 1 shadow zoning enabled: 0 shadow zone group: 1 device slot number: 255 device slot group number: 255 device slot group output connector: =20 Discover response: expander change count: 1328 phy identifier: 30 attached device type: SAS or SATA device attached reason: unknown negotiated logical link rate: phy enabled, 6 Gbps attached initiator: ssp=3D0 stp=3D0 smp=3D0 sata_host=3D0 attached sata port selector: 0 STP buffer too small: 0 attached target: ssp=3D0 stp=3D0 smp=3D0 sata_device=3D1 SAS address: 0x50030480017ae23f attached SAS address: 0x50030480017ae21e attached phy identifier: 0 attached persistent capable: 0 attached power capable: 0 attached slumber capable: 0 attached partial capable: 0 attached inside ZPSDS persistent: 0 attached requested inside ZPSDS: 0 attached break_reply capable: 0 attached pwr_dis capable: 0 programmed minimum physical link rate: 1.5 Gbps hardware minimum physical link rate: 1.5 Gbps programmed maximum physical link rate: 6 Gbps hardware maximum physical link rate: 6 Gbps phy change count: 45 virtual phy: 0 partial pathway timeout value: 7 us routing attribute: table connector type: SAS Drive backplane receptacle (SFF-8482) [max 2 phys] connector element index: 18 connector physical link: 0 phy power condition: 0 sas power capable: 0 sas slumber capable: 0 sas partial capable: 0 sata slumber capable: 0 sata partial capable: 0 pwr_dis signal: 0 pwr_dis control capable: 0 sas slumber enabled: 0 sas partial enabled: 0 sata slumber enabled: 0 sata partial enabled: 0 attached device name: 0x0 requested inside ZPSDS changed by expander: 0 inside ZPSDS persistent: 0 requested inside ZPSDS: 0 zone group persistent: 1 inside ZPSDS: 0 zoning enabled: 0 zone group: 1 self-configuration status: 0 self-configuration levels completed: 0 self-configuration sas address: 0x0 programmed phy capabilities: 0x0 current phy capabilities: 0x0 attached phy capabilities: 0x0 reason: unknown negotiated physical link rate: phy enabled, 6 Gbps optical mode enabled: 0 negotiated SSC: 0 hardware muxing supported: 0 default inside ZPSDS persistent: 0 default requested inside ZPSDS: 0 default zone group persistent: 1 default zoning enabled: 0 default zone group: 1 saved inside ZPSDS persistent: 0 saved requested inside ZPSDS: 0 saved zone group persistent: 1 saved zoning enabled: 0 saved zone group: 1 shadow inside ZPSDS persistent: 0 shadow requested inside ZPSDS: 0 shadow zone group persistent: 1 shadow zoning enabled: 0 shadow zone group: 1 device slot number: 255 device slot group number: 255 device slot group output connector: =20 Discover response: expander change count: 1328 phy identifier: 31 attached device type: SAS or SATA device attached reason: unknown negotiated logical link rate: phy enabled, 6 Gbps attached initiator: ssp=3D0 stp=3D0 smp=3D0 sata_host=3D0 attached sata port selector: 0 STP buffer too small: 0 attached target: ssp=3D0 stp=3D0 smp=3D0 sata_device=3D1 SAS address: 0x50030480017ae23f attached SAS address: 0x50030480017ae21f attached phy identifier: 0 attached persistent capable: 0 attached power capable: 0 attached slumber capable: 0 attached partial capable: 0 attached inside ZPSDS persistent: 0 attached requested inside ZPSDS: 0 attached break_reply capable: 0 attached pwr_dis capable: 0 programmed minimum physical link rate: 1.5 Gbps hardware minimum physical link rate: 1.5 Gbps programmed maximum physical link rate: 6 Gbps hardware maximum physical link rate: 6 Gbps phy change count: 45 virtual phy: 0 partial pathway timeout value: 7 us routing attribute: table connector type: SAS Drive backplane receptacle (SFF-8482) [max 2 phys] connector element index: 19 connector physical link: 0 phy power condition: 0 sas power capable: 0 sas slumber capable: 0 sas partial capable: 0 sata slumber capable: 0 sata partial capable: 0 pwr_dis signal: 0 pwr_dis control capable: 0 sas slumber enabled: 0 sas partial enabled: 0 sata slumber enabled: 0 sata partial enabled: 0 attached device name: 0x0 requested inside ZPSDS changed by expander: 0 inside ZPSDS persistent: 0 requested inside ZPSDS: 0 zone group persistent: 1 inside ZPSDS: 0 zoning enabled: 0 zone group: 1 self-configuration status: 0 self-configuration levels completed: 0 self-configuration sas address: 0x0 programmed phy capabilities: 0x0 current phy capabilities: 0x0 attached phy capabilities: 0x0 reason: unknown negotiated physical link rate: phy enabled, 6 Gbps optical mode enabled: 0 negotiated SSC: 0 hardware muxing supported: 0 default inside ZPSDS persistent: 0 default requested inside ZPSDS: 0 default zone group persistent: 1 default zoning enabled: 0 default zone group: 1 saved inside ZPSDS persistent: 0 saved requested inside ZPSDS: 0 saved zone group persistent: 1 saved zoning enabled: 0 saved zone group: 1 shadow inside ZPSDS persistent: 0 shadow requested inside ZPSDS: 0 shadow zone group persistent: 1 shadow zoning enabled: 0 shadow zone group: 1 device slot number: 255 device slot group number: 255 device slot group output connector: =20 Discover response: expander change count: 1328 phy identifier: 32 attached device type: SAS or SATA device attached reason: unknown negotiated logical link rate: phy enabled, 6 Gbps attached initiator: ssp=3D0 stp=3D0 smp=3D0 sata_host=3D0 attached sata port selector: 0 STP buffer too small: 0 attached target: ssp=3D0 stp=3D0 smp=3D0 sata_device=3D1 SAS address: 0x50030480017ae23f attached SAS address: 0x50030480017ae220 attached phy identifier: 0 attached persistent capable: 0 attached power capable: 0 attached slumber capable: 0 attached partial capable: 0 attached inside ZPSDS persistent: 0 attached requested inside ZPSDS: 0 attached break_reply capable: 0 attached pwr_dis capable: 0 programmed minimum physical link rate: 1.5 Gbps hardware minimum physical link rate: 1.5 Gbps programmed maximum physical link rate: 6 Gbps hardware maximum physical link rate: 6 Gbps phy change count: 45 virtual phy: 0 partial pathway timeout value: 7 us routing attribute: table connector type: SAS Drive backplane receptacle (SFF-8482) [max 2 phys] connector element index: 20 connector physical link: 0 phy power condition: 0 sas power capable: 0 sas slumber capable: 0 sas partial capable: 0 sata slumber capable: 0 sata partial capable: 0 pwr_dis signal: 0 pwr_dis control capable: 0 sas slumber enabled: 0 sas partial enabled: 0 sata slumber enabled: 0 sata partial enabled: 0 attached device name: 0x0 requested inside ZPSDS changed by expander: 0 inside ZPSDS persistent: 0 requested inside ZPSDS: 0 zone group persistent: 1 inside ZPSDS: 0 zoning enabled: 0 zone group: 1 self-configuration status: 0 self-configuration levels completed: 0 self-configuration sas address: 0x0 programmed phy capabilities: 0x0 current phy capabilities: 0x0 attached phy capabilities: 0x0 reason: unknown negotiated physical link rate: phy enabled, 6 Gbps optical mode enabled: 0 negotiated SSC: 0 hardware muxing supported: 0 default inside ZPSDS persistent: 0 default requested inside ZPSDS: 0 default zone group persistent: 1 default zoning enabled: 0 default zone group: 1 saved inside ZPSDS persistent: 0 saved requested inside ZPSDS: 0 saved zone group persistent: 1 saved zoning enabled: 0 saved zone group: 1 shadow inside ZPSDS persistent: 0 shadow requested inside ZPSDS: 0 shadow zone group persistent: 1 shadow zoning enabled: 0 shadow zone group: 1 device slot number: 255 device slot group number: 255 device slot group output connector: =20 Discover response: expander change count: 1328 phy identifier: 33 attached device type: SAS or SATA device attached reason: unknown negotiated logical link rate: phy enabled, 6 Gbps attached initiator: ssp=3D0 stp=3D0 smp=3D0 sata_host=3D0 attached sata port selector: 0 STP buffer too small: 0 attached target: ssp=3D0 stp=3D0 smp=3D0 sata_device=3D1 SAS address: 0x50030480017ae23f attached SAS address: 0x50030480017ae221 attached phy identifier: 0 attached persistent capable: 0 attached power capable: 0 attached slumber capable: 0 attached partial capable: 0 attached inside ZPSDS persistent: 0 attached requested inside ZPSDS: 0 attached break_reply capable: 0 attached pwr_dis capable: 0 programmed minimum physical link rate: 1.5 Gbps hardware minimum physical link rate: 1.5 Gbps programmed maximum physical link rate: 6 Gbps hardware maximum physical link rate: 6 Gbps phy change count: 45 virtual phy: 0 partial pathway timeout value: 7 us routing attribute: table connector type: SAS Drive backplane receptacle (SFF-8482) [max 2 phys] connector element index: 21 connector physical link: 0 phy power condition: 0 sas power capable: 0 sas slumber capable: 0 sas partial capable: 0 sata slumber capable: 0 sata partial capable: 0 pwr_dis signal: 0 pwr_dis control capable: 0 sas slumber enabled: 0 sas partial enabled: 0 sata slumber enabled: 0 sata partial enabled: 0 attached device name: 0x0 requested inside ZPSDS changed by expander: 0 inside ZPSDS persistent: 0 requested inside ZPSDS: 0 zone group persistent: 1 inside ZPSDS: 0 zoning enabled: 0 zone group: 1 self-configuration status: 0 self-configuration levels completed: 0 self-configuration sas address: 0x0 programmed phy capabilities: 0x0 current phy capabilities: 0x0 attached phy capabilities: 0x0 reason: unknown negotiated physical link rate: phy enabled, 6 Gbps optical mode enabled: 0 negotiated SSC: 0 hardware muxing supported: 0 default inside ZPSDS persistent: 0 default requested inside ZPSDS: 0 default zone group persistent: 1 default zoning enabled: 0 default zone group: 1 saved inside ZPSDS persistent: 0 saved requested inside ZPSDS: 0 saved zone group persistent: 1 saved zoning enabled: 0 saved zone group: 1 shadow inside ZPSDS persistent: 0 shadow requested inside ZPSDS: 0 shadow zone group persistent: 1 shadow zoning enabled: 0 shadow zone group: 1 device slot number: 255 device slot group number: 255 device slot group output connector: =20 Discover response: expander change count: 1328 phy identifier: 34 attached device type: SAS or SATA device attached reason: unknown negotiated logical link rate: phy enabled, 6 Gbps attached initiator: ssp=3D0 stp=3D0 smp=3D0 sata_host=3D0 attached sata port selector: 0 STP buffer too small: 0 attached target: ssp=3D0 stp=3D0 smp=3D0 sata_device=3D1 SAS address: 0x50030480017ae23f attached SAS address: 0x50030480017ae222 attached phy identifier: 0 attached persistent capable: 0 attached power capable: 0 attached slumber capable: 0 attached partial capable: 0 attached inside ZPSDS persistent: 0 attached requested inside ZPSDS: 0 attached break_reply capable: 0 attached pwr_dis capable: 0 programmed minimum physical link rate: 1.5 Gbps hardware minimum physical link rate: 1.5 Gbps programmed maximum physical link rate: 6 Gbps hardware maximum physical link rate: 6 Gbps phy change count: 45 virtual phy: 0 partial pathway timeout value: 7 us routing attribute: table connector type: SAS Drive backplane receptacle (SFF-8482) [max 2 phys] connector element index: 22 connector physical link: 0 phy power condition: 0 sas power capable: 0 sas slumber capable: 0 sas partial capable: 0 sata slumber capable: 0 sata partial capable: 0 pwr_dis signal: 0 pwr_dis control capable: 0 sas slumber enabled: 0 sas partial enabled: 0 sata slumber enabled: 0 sata partial enabled: 0 attached device name: 0x0 requested inside ZPSDS changed by expander: 0 inside ZPSDS persistent: 0 requested inside ZPSDS: 0 zone group persistent: 1 inside ZPSDS: 0 zoning enabled: 0 zone group: 1 self-configuration status: 0 self-configuration levels completed: 0 self-configuration sas address: 0x0 programmed phy capabilities: 0x0 current phy capabilities: 0x0 attached phy capabilities: 0x0 reason: unknown negotiated physical link rate: phy enabled, 6 Gbps optical mode enabled: 0 negotiated SSC: 0 hardware muxing supported: 0 default inside ZPSDS persistent: 0 default requested inside ZPSDS: 0 default zone group persistent: 1 default zoning enabled: 0 default zone group: 1 saved inside ZPSDS persistent: 0 saved requested inside ZPSDS: 0 saved zone group persistent: 1 saved zoning enabled: 0 saved zone group: 1 shadow inside ZPSDS persistent: 0 shadow requested inside ZPSDS: 0 shadow zone group persistent: 1 shadow zoning enabled: 0 shadow zone group: 1 device slot number: 255 device slot group number: 255 device slot group output connector: =20 Discover response: expander change count: 1328 phy identifier: 35 attached device type: SAS or SATA device attached reason: unknown negotiated logical link rate: phy enabled, 6 Gbps attached initiator: ssp=3D0 stp=3D0 smp=3D0 sata_host=3D0 attached sata port selector: 0 STP buffer too small: 0 attached target: ssp=3D0 stp=3D0 smp=3D0 sata_device=3D1 SAS address: 0x50030480017ae23f attached SAS address: 0x50030480017ae223 attached phy identifier: 0 attached persistent capable: 0 attached power capable: 0 attached slumber capable: 0 attached partial capable: 0 attached inside ZPSDS persistent: 0 attached requested inside ZPSDS: 0 attached break_reply capable: 0 attached pwr_dis capable: 0 programmed minimum physical link rate: 1.5 Gbps hardware minimum physical link rate: 1.5 Gbps programmed maximum physical link rate: 6 Gbps hardware maximum physical link rate: 6 Gbps phy change count: 45 virtual phy: 0 partial pathway timeout value: 7 us routing attribute: table connector type: SAS Drive backplane receptacle (SFF-8482) [max 2 phys] connector element index: 23 connector physical link: 0 phy power condition: 0 sas power capable: 0 sas slumber capable: 0 sas partial capable: 0 sata slumber capable: 0 sata partial capable: 0 pwr_dis signal: 0 pwr_dis control capable: 0 sas slumber enabled: 0 sas partial enabled: 0 sata slumber enabled: 0 sata partial enabled: 0 attached device name: 0x0 requested inside ZPSDS changed by expander: 0 inside ZPSDS persistent: 0 requested inside ZPSDS: 0 zone group persistent: 1 inside ZPSDS: 0 zoning enabled: 0 zone group: 1 self-configuration status: 0 self-configuration levels completed: 0 self-configuration sas address: 0x0 programmed phy capabilities: 0x0 current phy capabilities: 0x0 attached phy capabilities: 0x0 reason: unknown negotiated physical link rate: phy enabled, 6 Gbps optical mode enabled: 0 negotiated SSC: 0 hardware muxing supported: 0 default inside ZPSDS persistent: 0 default requested inside ZPSDS: 0 default zone group persistent: 1 default zoning enabled: 0 default zone group: 1 saved inside ZPSDS persistent: 0 saved requested inside ZPSDS: 0 saved zone group persistent: 1 saved zoning enabled: 0 saved zone group: 1 shadow inside ZPSDS persistent: 0 shadow requested inside ZPSDS: 0 shadow zone group persistent: 1 shadow zoning enabled: 0 shadow zone group: 1 device slot number: 255 device slot group number: 255 device slot group output connector: =20 Discover response: expander change count: 1328 phy identifier: 36 attached device type: SAS or SATA device attached reason: unknown negotiated logical link rate: phy enabled, 6 Gbps attached initiator: ssp=3D1 stp=3D0 smp=3D1 sata_host=3D0 attached sata port selector: 0 STP buffer too small: 0 attached target: ssp=3D1 stp=3D0 smp=3D0 sata_device=3D0 SAS address: 0x50030480017ae23f attached SAS address: 0x50030480017ae23d attached phy identifier: 0 attached persistent capable: 0 attached power capable: 0 attached slumber capable: 0 attached partial capable: 0 attached inside ZPSDS persistent: 0 attached requested inside ZPSDS: 0 attached break_reply capable: 0 attached pwr_dis capable: 0 programmed minimum physical link rate: 6 Gbps hardware minimum physical link rate: 6 Gbps programmed maximum physical link rate: 6 Gbps hardware maximum physical link rate: 6 Gbps phy change count: 1 virtual phy: 1 partial pathway timeout value: 7 us routing attribute: direct connector type: SAS virtual connector [max 1 phy] connector element index: 24 connector physical link: 0 phy power condition: 0 sas power capable: 0 sas slumber capable: 0 sas partial capable: 0 sata slumber capable: 0 sata partial capable: 0 pwr_dis signal: 0 pwr_dis control capable: 0 sas slumber enabled: 0 sas partial enabled: 0 sata slumber enabled: 0 sata partial enabled: 0 attached device name: 0x0 requested inside ZPSDS changed by expander: 0 inside ZPSDS persistent: 0 requested inside ZPSDS: 0 zone group persistent: 1 inside ZPSDS: 1 zoning enabled: 0 zone group: 1 self-configuration status: 0 self-configuration levels completed: 0 self-configuration sas address: 0x0 programmed phy capabilities: 0x0 current phy capabilities: 0x0 attached phy capabilities: 0x0 reason: unknown negotiated physical link rate: phy enabled, 6 Gbps optical mode enabled: 0 negotiated SSC: 0 hardware muxing supported: 0 default inside ZPSDS persistent: 0 default requested inside ZPSDS: 0 default zone group persistent: 1 default zoning enabled: 0 default zone group: 1 saved inside ZPSDS persistent: 0 saved requested inside ZPSDS: 0 saved zone group persistent: 1 saved zoning enabled: 0 saved zone group: 1 shadow inside ZPSDS persistent: 0 shadow requested inside ZPSDS: 0 shadow zone group persistent: 1 shadow zoning enabled: 0 shadow zone group: 1 device slot number: 255 device slot group number: 255 device slot group output connector: =20 root@rhea:~ # smp_discover ses1 phy 0:S:attached:[50030480017ae23f:04 exp t(SMP)] 6 Gbps phy 1:S:attached:[50030480017ae23f:05 exp t(SMP)] 6 Gbps phy 2:S:attached:[50030480017ae23f:06 exp t(SMP)] 6 Gbps phy 3:S:attached:[50030480017ae23f:07 exp t(SMP)] 6 Gbps phy 8:D:disabled phy 9:D:disabled phy 10:D:disabled phy 11:D:disabled phy 12:U:attached:[50030480017bd5ac:00 t(SATA)] 6 Gbps phy 13:U:attached:[50030480017bd5ad:00 t(SATA)] 6 Gbps phy 14:U:attached:[50030480017bd5ae:00 t(SATA)] 6 Gbps phy 15:U:attached:[50030480017bd5af:00 t(SATA)] 6 Gbps phy 16:U:attached:[50030480017bd5b0:00 t(SATA)] 6 Gbps phy 17:U:attached:[50030480017bd5b1:00 t(SATA)] 6 Gbps phy 18:U:attached:[50030480017bd5b2:00 t(SATA)] 6 Gbps phy 19:U:attached:[50030480017bd5b3:00 t(SATA)] 6 Gbps phy 20:U:attached:[50030480017bd5b4:00 t(SATA)] 6 Gbps phy 21:U:attached:[50030480017bd5b5:00 t(SATA)] 6 Gbps phy 22:U:attached:[50030480017bd5b6:00 t(SATA)] 6 Gbps phy 23:U:attached:[50030480017bd5b7:00 t(SATA)] 6 Gbps phy 24:D:disabled phy 25:D:disabled phy 26:D:disabled phy 27:D:disabled phy 28:D:attached:[50030480017bd5bd:00 V i(SSP+SMP) t(SSP)] 6 Gbps root@rhea:~ # foreach PHY ( `seq 0 1 28` ) foreach? smp_discover -p $PHY ses1 foreach? end Discover response: expander change count: 241 phy identifier: 0 attached device type: expander device attached reason: loss of dword synchronization negotiated logical link rate: phy enabled, 6 Gbps attached initiator: ssp=3D0 stp=3D0 smp=3D0 sata_host=3D0 attached sata port selector: 0 STP buffer too small: 0 attached target: ssp=3D0 stp=3D0 smp=3D1 sata_device=3D0 SAS address: 0x50030480017bd5bf attached SAS address: 0x50030480017ae23f attached phy identifier: 4 attached persistent capable: 0 attached power capable: 0 attached slumber capable: 0 attached partial capable: 0 attached inside ZPSDS persistent: 0 attached requested inside ZPSDS: 0 attached break_reply capable: 1 attached pwr_dis capable: 0 programmed minimum physical link rate: 1.5 Gbps hardware minimum physical link rate: 1.5 Gbps programmed maximum physical link rate: 6 Gbps hardware maximum physical link rate: 6 Gbps phy change count: 1 virtual phy: 0 partial pathway timeout value: 7 us routing attribute: subtractive connector type: No information connector element index: 0 connector physical link: 0 phy power condition: 0 sas power capable: 0 sas slumber capable: 0 sas partial capable: 0 sata slumber capable: 0 sata partial capable: 0 pwr_dis signal: 0 pwr_dis control capable: 0 sas slumber enabled: 0 sas partial enabled: 0 sata slumber enabled: 0 sata partial enabled: 0 attached device name: 0x50030480017ae23f requested inside ZPSDS changed by expander: 0 inside ZPSDS persistent: 0 requested inside ZPSDS: 0 zone group persistent: 1 inside ZPSDS: 0 zoning enabled: 0 zone group: 1 self-configuration status: 0 self-configuration levels completed: 1 self-configuration sas address: 0x0 programmed phy capabilities: 0x0 current phy capabilities: 0x0 attached phy capabilities: 0x0 reason: unknown negotiated physical link rate: phy enabled, 6 Gbps optical mode enabled: 0 negotiated SSC: 0 hardware muxing supported: 0 default inside ZPSDS persistent: 0 default requested inside ZPSDS: 0 default zone group persistent: 1 default zoning enabled: 0 default zone group: 1 saved inside ZPSDS persistent: 0 saved requested inside ZPSDS: 0 saved zone group persistent: 1 saved zoning enabled: 0 saved zone group: 1 shadow inside ZPSDS persistent: 0 shadow requested inside ZPSDS: 0 shadow zone group persistent: 1 shadow zoning enabled: 0 shadow zone group: 1 device slot number: 255 device slot group number: 255 device slot group output connector: =20 Discover response: expander change count: 241 phy identifier: 1 attached device type: expander device attached reason: loss of dword synchronization negotiated logical link rate: phy enabled, 6 Gbps attached initiator: ssp=3D0 stp=3D0 smp=3D0 sata_host=3D0 attached sata port selector: 0 STP buffer too small: 0 attached target: ssp=3D0 stp=3D0 smp=3D1 sata_device=3D0 SAS address: 0x50030480017bd5bf attached SAS address: 0x50030480017ae23f attached phy identifier: 5 attached persistent capable: 0 attached power capable: 0 attached slumber capable: 0 attached partial capable: 0 attached inside ZPSDS persistent: 0 attached requested inside ZPSDS: 0 attached break_reply capable: 1 attached pwr_dis capable: 0 programmed minimum physical link rate: 1.5 Gbps hardware minimum physical link rate: 1.5 Gbps programmed maximum physical link rate: 6 Gbps hardware maximum physical link rate: 6 Gbps phy change count: 1 virtual phy: 0 partial pathway timeout value: 7 us routing attribute: subtractive connector type: No information connector element index: 0 connector physical link: 0 phy power condition: 0 sas power capable: 0 sas slumber capable: 0 sas partial capable: 0 sata slumber capable: 0 sata partial capable: 0 pwr_dis signal: 0 pwr_dis control capable: 0 sas slumber enabled: 0 sas partial enabled: 0 sata slumber enabled: 0 sata partial enabled: 0 attached device name: 0x50030480017ae23f requested inside ZPSDS changed by expander: 0 inside ZPSDS persistent: 0 requested inside ZPSDS: 0 zone group persistent: 1 inside ZPSDS: 0 zoning enabled: 0 zone group: 1 self-configuration status: 0 self-configuration levels completed: 1 self-configuration sas address: 0x0 programmed phy capabilities: 0x0 current phy capabilities: 0x0 attached phy capabilities: 0x0 reason: unknown negotiated physical link rate: phy enabled, 6 Gbps optical mode enabled: 0 negotiated SSC: 0 hardware muxing supported: 0 default inside ZPSDS persistent: 0 default requested inside ZPSDS: 0 default zone group persistent: 1 default zoning enabled: 0 default zone group: 1 saved inside ZPSDS persistent: 0 saved requested inside ZPSDS: 0 saved zone group persistent: 1 saved zoning enabled: 0 saved zone group: 1 shadow inside ZPSDS persistent: 0 shadow requested inside ZPSDS: 0 shadow zone group persistent: 1 shadow zoning enabled: 0 shadow zone group: 1 device slot number: 255 device slot group number: 255 device slot group output connector: =20 Discover response: expander change count: 241 phy identifier: 2 attached device type: expander device attached reason: loss of dword synchronization negotiated logical link rate: phy enabled, 6 Gbps attached initiator: ssp=3D0 stp=3D0 smp=3D0 sata_host=3D0 attached sata port selector: 0 STP buffer too small: 0 attached target: ssp=3D0 stp=3D0 smp=3D1 sata_device=3D0 SAS address: 0x50030480017bd5bf attached SAS address: 0x50030480017ae23f attached phy identifier: 6 attached persistent capable: 0 attached power capable: 0 attached slumber capable: 0 attached partial capable: 0 attached inside ZPSDS persistent: 0 attached requested inside ZPSDS: 0 attached break_reply capable: 1 attached pwr_dis capable: 0 programmed minimum physical link rate: 1.5 Gbps hardware minimum physical link rate: 1.5 Gbps programmed maximum physical link rate: 6 Gbps hardware maximum physical link rate: 6 Gbps phy change count: 1 virtual phy: 0 partial pathway timeout value: 7 us routing attribute: subtractive connector type: No information connector element index: 0 connector physical link: 0 phy power condition: 0 sas power capable: 0 sas slumber capable: 0 sas partial capable: 0 sata slumber capable: 0 sata partial capable: 0 pwr_dis signal: 0 pwr_dis control capable: 0 sas slumber enabled: 0 sas partial enabled: 0 sata slumber enabled: 0 sata partial enabled: 0 attached device name: 0x50030480017ae23f requested inside ZPSDS changed by expander: 0 inside ZPSDS persistent: 0 requested inside ZPSDS: 0 zone group persistent: 1 inside ZPSDS: 0 zoning enabled: 0 zone group: 1 self-configuration status: 0 self-configuration levels completed: 1 self-configuration sas address: 0x0 programmed phy capabilities: 0x0 current phy capabilities: 0x0 attached phy capabilities: 0x0 reason: unknown negotiated physical link rate: phy enabled, 6 Gbps optical mode enabled: 0 negotiated SSC: 0 hardware muxing supported: 0 default inside ZPSDS persistent: 0 default requested inside ZPSDS: 0 default zone group persistent: 1 default zoning enabled: 0 default zone group: 1 saved inside ZPSDS persistent: 0 saved requested inside ZPSDS: 0 saved zone group persistent: 1 saved zoning enabled: 0 saved zone group: 1 shadow inside ZPSDS persistent: 0 shadow requested inside ZPSDS: 0 shadow zone group persistent: 1 shadow zoning enabled: 0 shadow zone group: 1 device slot number: 255 device slot group number: 255 device slot group output connector: =20 Discover response: expander change count: 241 phy identifier: 3 attached device type: expander device attached reason: loss of dword synchronization negotiated logical link rate: phy enabled, 6 Gbps attached initiator: ssp=3D0 stp=3D0 smp=3D0 sata_host=3D0 attached sata port selector: 0 STP buffer too small: 0 attached target: ssp=3D0 stp=3D0 smp=3D1 sata_device=3D0 SAS address: 0x50030480017bd5bf attached SAS address: 0x50030480017ae23f attached phy identifier: 7 attached persistent capable: 0 attached power capable: 0 attached slumber capable: 0 attached partial capable: 0 attached inside ZPSDS persistent: 0 attached requested inside ZPSDS: 0 attached break_reply capable: 1 attached pwr_dis capable: 0 programmed minimum physical link rate: 1.5 Gbps hardware minimum physical link rate: 1.5 Gbps programmed maximum physical link rate: 6 Gbps hardware maximum physical link rate: 6 Gbps phy change count: 1 virtual phy: 0 partial pathway timeout value: 7 us routing attribute: subtractive connector type: No information connector element index: 0 connector physical link: 0 phy power condition: 0 sas power capable: 0 sas slumber capable: 0 sas partial capable: 0 sata slumber capable: 0 sata partial capable: 0 pwr_dis signal: 0 pwr_dis control capable: 0 sas slumber enabled: 0 sas partial enabled: 0 sata slumber enabled: 0 sata partial enabled: 0 attached device name: 0x50030480017ae23f requested inside ZPSDS changed by expander: 0 inside ZPSDS persistent: 0 requested inside ZPSDS: 0 zone group persistent: 1 inside ZPSDS: 0 zoning enabled: 0 zone group: 1 self-configuration status: 0 self-configuration levels completed: 1 self-configuration sas address: 0x0 programmed phy capabilities: 0x0 current phy capabilities: 0x0 attached phy capabilities: 0x0 reason: unknown negotiated physical link rate: phy enabled, 6 Gbps optical mode enabled: 0 negotiated SSC: 0 hardware muxing supported: 0 default inside ZPSDS persistent: 0 default requested inside ZPSDS: 0 default zone group persistent: 1 default zoning enabled: 0 default zone group: 1 saved inside ZPSDS persistent: 0 saved requested inside ZPSDS: 0 saved zone group persistent: 1 saved zoning enabled: 0 saved zone group: 1 shadow inside ZPSDS persistent: 0 shadow requested inside ZPSDS: 0 shadow zone group persistent: 1 shadow zoning enabled: 0 shadow zone group: 1 device slot number: 255 device slot group number: 255 device slot group output connector: =20 Discover response: expander change count: 241 phy identifier: 4 attached device type: no device attached attached reason: unknown negotiated logical link rate: phy enabled; unknown attached initiator: ssp=3D0 stp=3D0 smp=3D0 sata_host=3D0 attached sata port selector: 0 STP buffer too small: 0 attached target: ssp=3D0 stp=3D0 smp=3D0 sata_device=3D0 SAS address: 0x50030480017bd5bf attached SAS address: 0x0 attached phy identifier: 0 attached persistent capable: 0 attached power capable: 0 attached slumber capable: 0 attached partial capable: 0 attached inside ZPSDS persistent: 0 attached requested inside ZPSDS: 0 attached break_reply capable: 0 attached pwr_dis capable: 0 programmed minimum physical link rate: 1.5 Gbps hardware minimum physical link rate: 1.5 Gbps programmed maximum physical link rate: 6 Gbps hardware maximum physical link rate: 6 Gbps phy change count: 1 virtual phy: 0 partial pathway timeout value: 7 us routing attribute: table connector type: No information connector element index: 0 connector physical link: 0 phy power condition: 0 sas power capable: 0 sas slumber capable: 0 sas partial capable: 0 sata slumber capable: 0 sata partial capable: 0 pwr_dis signal: 0 pwr_dis control capable: 0 sas slumber enabled: 0 sas partial enabled: 0 sata slumber enabled: 0 sata partial enabled: 0 attached device name: 0x0 requested inside ZPSDS changed by expander: 0 inside ZPSDS persistent: 0 requested inside ZPSDS: 0 zone group persistent: 1 inside ZPSDS: 0 zoning enabled: 0 zone group: 1 self-configuration status: 0 self-configuration levels completed: 0 self-configuration sas address: 0x0 programmed phy capabilities: 0x0 current phy capabilities: 0x0 attached phy capabilities: 0x0 reason: unknown negotiated physical link rate: phy enabled; unknown optical mode enabled: 0 negotiated SSC: 0 hardware muxing supported: 0 default inside ZPSDS persistent: 0 default requested inside ZPSDS: 0 default zone group persistent: 1 default zoning enabled: 0 default zone group: 1 saved inside ZPSDS persistent: 0 saved requested inside ZPSDS: 0 saved zone group persistent: 1 saved zoning enabled: 0 saved zone group: 1 shadow inside ZPSDS persistent: 0 shadow requested inside ZPSDS: 0 shadow zone group persistent: 1 shadow zoning enabled: 0 shadow zone group: 1 device slot number: 255 device slot group number: 255 device slot group output connector: =20 Discover response: expander change count: 241 phy identifier: 5 attached device type: no device attached attached reason: unknown negotiated logical link rate: phy enabled; unknown attached initiator: ssp=3D0 stp=3D0 smp=3D0 sata_host=3D0 attached sata port selector: 0 STP buffer too small: 0 attached target: ssp=3D0 stp=3D0 smp=3D0 sata_device=3D0 SAS address: 0x50030480017bd5bf attached SAS address: 0x0 attached phy identifier: 0 attached persistent capable: 0 attached power capable: 0 attached slumber capable: 0 attached partial capable: 0 attached inside ZPSDS persistent: 0 attached requested inside ZPSDS: 0 attached break_reply capable: 0 attached pwr_dis capable: 0 programmed minimum physical link rate: 1.5 Gbps hardware minimum physical link rate: 1.5 Gbps programmed maximum physical link rate: 6 Gbps hardware maximum physical link rate: 6 Gbps phy change count: 1 virtual phy: 0 partial pathway timeout value: 7 us routing attribute: table connector type: No information connector element index: 0 connector physical link: 0 phy power condition: 0 sas power capable: 0 sas slumber capable: 0 sas partial capable: 0 sata slumber capable: 0 sata partial capable: 0 pwr_dis signal: 0 pwr_dis control capable: 0 sas slumber enabled: 0 sas partial enabled: 0 sata slumber enabled: 0 sata partial enabled: 0 attached device name: 0x0 requested inside ZPSDS changed by expander: 0 inside ZPSDS persistent: 0 requested inside ZPSDS: 0 zone group persistent: 1 inside ZPSDS: 0 zoning enabled: 0 zone group: 1 self-configuration status: 0 self-configuration levels completed: 0 self-configuration sas address: 0x0 programmed phy capabilities: 0x0 current phy capabilities: 0x0 attached phy capabilities: 0x0 reason: unknown negotiated physical link rate: phy enabled; unknown optical mode enabled: 0 negotiated SSC: 0 hardware muxing supported: 0 default inside ZPSDS persistent: 0 default requested inside ZPSDS: 0 default zone group persistent: 1 default zoning enabled: 0 default zone group: 1 saved inside ZPSDS persistent: 0 saved requested inside ZPSDS: 0 saved zone group persistent: 1 saved zoning enabled: 0 saved zone group: 1 shadow inside ZPSDS persistent: 0 shadow requested inside ZPSDS: 0 shadow zone group persistent: 1 shadow zoning enabled: 0 shadow zone group: 1 device slot number: 255 device slot group number: 255 device slot group output connector: =20 Discover response: expander change count: 241 phy identifier: 6 attached device type: no device attached attached reason: unknown negotiated logical link rate: phy enabled; unknown attached initiator: ssp=3D0 stp=3D0 smp=3D0 sata_host=3D0 attached sata port selector: 0 STP buffer too small: 0 attached target: ssp=3D0 stp=3D0 smp=3D0 sata_device=3D0 SAS address: 0x50030480017bd5bf attached SAS address: 0x0 attached phy identifier: 0 attached persistent capable: 0 attached power capable: 0 attached slumber capable: 0 attached partial capable: 0 attached inside ZPSDS persistent: 0 attached requested inside ZPSDS: 0 attached break_reply capable: 0 attached pwr_dis capable: 0 programmed minimum physical link rate: 1.5 Gbps hardware minimum physical link rate: 1.5 Gbps programmed maximum physical link rate: 6 Gbps hardware maximum physical link rate: 6 Gbps phy change count: 1 virtual phy: 0 partial pathway timeout value: 7 us routing attribute: table connector type: No information connector element index: 0 connector physical link: 0 phy power condition: 0 sas power capable: 0 sas slumber capable: 0 sas partial capable: 0 sata slumber capable: 0 sata partial capable: 0 pwr_dis signal: 0 pwr_dis control capable: 0 sas slumber enabled: 0 sas partial enabled: 0 sata slumber enabled: 0 sata partial enabled: 0 attached device name: 0x0 requested inside ZPSDS changed by expander: 0 inside ZPSDS persistent: 0 requested inside ZPSDS: 0 zone group persistent: 1 inside ZPSDS: 0 zoning enabled: 0 zone group: 1 self-configuration status: 0 self-configuration levels completed: 0 self-configuration sas address: 0x0 programmed phy capabilities: 0x0 current phy capabilities: 0x0 attached phy capabilities: 0x0 reason: unknown negotiated physical link rate: phy enabled; unknown optical mode enabled: 0 negotiated SSC: 0 hardware muxing supported: 0 default inside ZPSDS persistent: 0 default requested inside ZPSDS: 0 default zone group persistent: 1 default zoning enabled: 0 default zone group: 1 saved inside ZPSDS persistent: 0 saved requested inside ZPSDS: 0 saved zone group persistent: 1 saved zoning enabled: 0 saved zone group: 1 shadow inside ZPSDS persistent: 0 shadow requested inside ZPSDS: 0 shadow zone group persistent: 1 shadow zoning enabled: 0 shadow zone group: 1 device slot number: 255 device slot group number: 255 device slot group output connector: =20 Discover response: expander change count: 241 phy identifier: 7 attached device type: no device attached attached reason: unknown negotiated logical link rate: phy enabled; unknown attached initiator: ssp=3D0 stp=3D0 smp=3D0 sata_host=3D0 attached sata port selector: 0 STP buffer too small: 0 attached target: ssp=3D0 stp=3D0 smp=3D0 sata_device=3D0 SAS address: 0x50030480017bd5bf attached SAS address: 0x0 attached phy identifier: 0 attached persistent capable: 0 attached power capable: 0 attached slumber capable: 0 attached partial capable: 0 attached inside ZPSDS persistent: 0 attached requested inside ZPSDS: 0 attached break_reply capable: 0 attached pwr_dis capable: 0 programmed minimum physical link rate: 1.5 Gbps hardware minimum physical link rate: 1.5 Gbps programmed maximum physical link rate: 6 Gbps hardware maximum physical link rate: 6 Gbps phy change count: 1 virtual phy: 0 partial pathway timeout value: 7 us routing attribute: table connector type: No information connector element index: 0 connector physical link: 0 phy power condition: 0 sas power capable: 0 sas slumber capable: 0 sas partial capable: 0 sata slumber capable: 0 sata partial capable: 0 pwr_dis signal: 0 pwr_dis control capable: 0 sas slumber enabled: 0 sas partial enabled: 0 sata slumber enabled: 0 sata partial enabled: 0 attached device name: 0x0 requested inside ZPSDS changed by expander: 0 inside ZPSDS persistent: 0 requested inside ZPSDS: 0 zone group persistent: 1 inside ZPSDS: 0 zoning enabled: 0 zone group: 1 self-configuration status: 0 self-configuration levels completed: 0 self-configuration sas address: 0x0 programmed phy capabilities: 0x0 current phy capabilities: 0x0 attached phy capabilities: 0x0 reason: unknown negotiated physical link rate: phy enabled; unknown optical mode enabled: 0 negotiated SSC: 0 hardware muxing supported: 0 default inside ZPSDS persistent: 0 default requested inside ZPSDS: 0 default zone group persistent: 1 default zoning enabled: 0 default zone group: 1 saved inside ZPSDS persistent: 0 saved requested inside ZPSDS: 0 saved zone group persistent: 1 saved zoning enabled: 0 saved zone group: 1 shadow inside ZPSDS persistent: 0 shadow requested inside ZPSDS: 0 shadow zone group persistent: 1 shadow zoning enabled: 0 shadow zone group: 1 device slot number: 255 device slot group number: 255 device slot group output connector: =20 Discover response: expander change count: 241 phy identifier: 8 attached device type: no device attached attached reason: unknown negotiated logical link rate: phy disabled attached initiator: ssp=3D0 stp=3D0 smp=3D0 sata_host=3D0 attached sata port selector: 0 STP buffer too small: 0 attached target: ssp=3D0 stp=3D0 smp=3D0 sata_device=3D0 SAS address: 0x50030480017bd5bf attached SAS address: 0x0 attached phy identifier: 0 attached persistent capable: 0 attached power capable: 0 attached slumber capable: 0 attached partial capable: 0 attached inside ZPSDS persistent: 0 attached requested inside ZPSDS: 0 attached break_reply capable: 0 attached pwr_dis capable: 0 programmed minimum physical link rate: 1.5 Gbps hardware minimum physical link rate: 1.5 Gbps programmed maximum physical link rate: 6 Gbps hardware maximum physical link rate: 6 Gbps phy change count: 1 virtual phy: 0 partial pathway timeout value: 7 us routing attribute: direct connector type: No information connector element index: 0 connector physical link: 0 phy power condition: 0 sas power capable: 0 sas slumber capable: 0 sas partial capable: 0 sata slumber capable: 0 sata partial capable: 0 pwr_dis signal: 0 pwr_dis control capable: 0 sas slumber enabled: 0 sas partial enabled: 0 sata slumber enabled: 0 sata partial enabled: 0 attached device name: 0x0 requested inside ZPSDS changed by expander: 0 inside ZPSDS persistent: 0 requested inside ZPSDS: 0 zone group persistent: 1 inside ZPSDS: 0 zoning enabled: 0 zone group: 1 self-configuration status: 0 self-configuration levels completed: 0 self-configuration sas address: 0x0 programmed phy capabilities: 0x0 current phy capabilities: 0x0 attached phy capabilities: 0x0 reason: unknown negotiated physical link rate: phy disabled optical mode enabled: 0 negotiated SSC: 0 hardware muxing supported: 0 default inside ZPSDS persistent: 0 default requested inside ZPSDS: 0 default zone group persistent: 1 default zoning enabled: 0 default zone group: 1 saved inside ZPSDS persistent: 0 saved requested inside ZPSDS: 0 saved zone group persistent: 1 saved zoning enabled: 0 saved zone group: 1 shadow inside ZPSDS persistent: 0 shadow requested inside ZPSDS: 0 shadow zone group persistent: 1 shadow zoning enabled: 0 shadow zone group: 1 device slot number: 255 device slot group number: 255 device slot group output connector: =20 Discover response: expander change count: 241 phy identifier: 9 attached device type: no device attached attached reason: unknown negotiated logical link rate: phy disabled attached initiator: ssp=3D0 stp=3D0 smp=3D0 sata_host=3D0 attached sata port selector: 0 STP buffer too small: 0 attached target: ssp=3D0 stp=3D0 smp=3D0 sata_device=3D0 SAS address: 0x50030480017bd5bf attached SAS address: 0x0 attached phy identifier: 0 attached persistent capable: 0 attached power capable: 0 attached slumber capable: 0 attached partial capable: 0 attached inside ZPSDS persistent: 0 attached requested inside ZPSDS: 0 attached break_reply capable: 0 attached pwr_dis capable: 0 programmed minimum physical link rate: 1.5 Gbps hardware minimum physical link rate: 1.5 Gbps programmed maximum physical link rate: 6 Gbps hardware maximum physical link rate: 6 Gbps phy change count: 1 virtual phy: 0 partial pathway timeout value: 7 us routing attribute: direct connector type: No information connector element index: 0 connector physical link: 0 phy power condition: 0 sas power capable: 0 sas slumber capable: 0 sas partial capable: 0 sata slumber capable: 0 sata partial capable: 0 pwr_dis signal: 0 pwr_dis control capable: 0 sas slumber enabled: 0 sas partial enabled: 0 sata slumber enabled: 0 sata partial enabled: 0 attached device name: 0x0 requested inside ZPSDS changed by expander: 0 inside ZPSDS persistent: 0 requested inside ZPSDS: 0 zone group persistent: 1 inside ZPSDS: 0 zoning enabled: 0 zone group: 1 self-configuration status: 0 self-configuration levels completed: 0 self-configuration sas address: 0x0 programmed phy capabilities: 0x0 current phy capabilities: 0x0 attached phy capabilities: 0x0 reason: unknown negotiated physical link rate: phy disabled optical mode enabled: 0 negotiated SSC: 0 hardware muxing supported: 0 default inside ZPSDS persistent: 0 default requested inside ZPSDS: 0 default zone group persistent: 1 default zoning enabled: 0 default zone group: 1 saved inside ZPSDS persistent: 0 saved requested inside ZPSDS: 0 saved zone group persistent: 1 saved zoning enabled: 0 saved zone group: 1 shadow inside ZPSDS persistent: 0 shadow requested inside ZPSDS: 0 shadow zone group persistent: 1 shadow zoning enabled: 0 shadow zone group: 1 device slot number: 255 device slot group number: 255 device slot group output connector: =20 Discover response: expander change count: 241 phy identifier: 10 attached device type: no device attached attached reason: unknown negotiated logical link rate: phy disabled attached initiator: ssp=3D0 stp=3D0 smp=3D0 sata_host=3D0 attached sata port selector: 0 STP buffer too small: 0 attached target: ssp=3D0 stp=3D0 smp=3D0 sata_device=3D0 SAS address: 0x50030480017bd5bf attached SAS address: 0x0 attached phy identifier: 0 attached persistent capable: 0 attached power capable: 0 attached slumber capable: 0 attached partial capable: 0 attached inside ZPSDS persistent: 0 attached requested inside ZPSDS: 0 attached break_reply capable: 0 attached pwr_dis capable: 0 programmed minimum physical link rate: 1.5 Gbps hardware minimum physical link rate: 1.5 Gbps programmed maximum physical link rate: 6 Gbps hardware maximum physical link rate: 6 Gbps phy change count: 1 virtual phy: 0 partial pathway timeout value: 7 us routing attribute: direct connector type: No information connector element index: 0 connector physical link: 0 phy power condition: 0 sas power capable: 0 sas slumber capable: 0 sas partial capable: 0 sata slumber capable: 0 sata partial capable: 0 pwr_dis signal: 0 pwr_dis control capable: 0 sas slumber enabled: 0 sas partial enabled: 0 sata slumber enabled: 0 sata partial enabled: 0 attached device name: 0x0 requested inside ZPSDS changed by expander: 0 inside ZPSDS persistent: 0 requested inside ZPSDS: 0 zone group persistent: 1 inside ZPSDS: 0 zoning enabled: 0 zone group: 1 self-configuration status: 0 self-configuration levels completed: 0 self-configuration sas address: 0x0 programmed phy capabilities: 0x0 current phy capabilities: 0x0 attached phy capabilities: 0x0 reason: unknown negotiated physical link rate: phy disabled optical mode enabled: 0 negotiated SSC: 0 hardware muxing supported: 0 default inside ZPSDS persistent: 0 default requested inside ZPSDS: 0 default zone group persistent: 1 default zoning enabled: 0 default zone group: 1 saved inside ZPSDS persistent: 0 saved requested inside ZPSDS: 0 saved zone group persistent: 1 saved zoning enabled: 0 saved zone group: 1 shadow inside ZPSDS persistent: 0 shadow requested inside ZPSDS: 0 shadow zone group persistent: 1 shadow zoning enabled: 0 shadow zone group: 1 device slot number: 255 device slot group number: 255 device slot group output connector: =20 Discover response: expander change count: 241 phy identifier: 11 attached device type: no device attached attached reason: unknown negotiated logical link rate: phy disabled attached initiator: ssp=3D0 stp=3D0 smp=3D0 sata_host=3D0 attached sata port selector: 0 STP buffer too small: 0 attached target: ssp=3D0 stp=3D0 smp=3D0 sata_device=3D0 SAS address: 0x50030480017bd5bf attached SAS address: 0x0 attached phy identifier: 0 attached persistent capable: 0 attached power capable: 0 attached slumber capable: 0 attached partial capable: 0 attached inside ZPSDS persistent: 0 attached requested inside ZPSDS: 0 attached break_reply capable: 0 attached pwr_dis capable: 0 programmed minimum physical link rate: 1.5 Gbps hardware minimum physical link rate: 1.5 Gbps programmed maximum physical link rate: 6 Gbps hardware maximum physical link rate: 6 Gbps phy change count: 1 virtual phy: 0 partial pathway timeout value: 7 us routing attribute: direct connector type: No information connector element index: 0 connector physical link: 0 phy power condition: 0 sas power capable: 0 sas slumber capable: 0 sas partial capable: 0 sata slumber capable: 0 sata partial capable: 0 pwr_dis signal: 0 pwr_dis control capable: 0 sas slumber enabled: 0 sas partial enabled: 0 sata slumber enabled: 0 sata partial enabled: 0 attached device name: 0x0 requested inside ZPSDS changed by expander: 0 inside ZPSDS persistent: 0 requested inside ZPSDS: 0 zone group persistent: 1 inside ZPSDS: 0 zoning enabled: 0 zone group: 1 self-configuration status: 0 self-configuration levels completed: 0 self-configuration sas address: 0x0 programmed phy capabilities: 0x0 current phy capabilities: 0x0 attached phy capabilities: 0x0 reason: unknown negotiated physical link rate: phy disabled optical mode enabled: 0 negotiated SSC: 0 hardware muxing supported: 0 default inside ZPSDS persistent: 0 default requested inside ZPSDS: 0 default zone group persistent: 1 default zoning enabled: 0 default zone group: 1 saved inside ZPSDS persistent: 0 saved requested inside ZPSDS: 0 saved zone group persistent: 1 saved zoning enabled: 0 saved zone group: 1 shadow inside ZPSDS persistent: 0 shadow requested inside ZPSDS: 0 shadow zone group persistent: 1 shadow zoning enabled: 0 shadow zone group: 1 device slot number: 255 device slot group number: 255 device slot group output connector: =20 Discover response: expander change count: 241 phy identifier: 12 attached device type: SAS or SATA device attached reason: unknown negotiated logical link rate: phy enabled, 6 Gbps attached initiator: ssp=3D0 stp=3D0 smp=3D0 sata_host=3D0 attached sata port selector: 0 STP buffer too small: 0 attached target: ssp=3D0 stp=3D0 smp=3D0 sata_device=3D1 SAS address: 0x50030480017bd5bf attached SAS address: 0x50030480017bd5ac attached phy identifier: 0 attached persistent capable: 0 attached power capable: 0 attached slumber capable: 0 attached partial capable: 0 attached inside ZPSDS persistent: 0 attached requested inside ZPSDS: 0 attached break_reply capable: 0 attached pwr_dis capable: 0 programmed minimum physical link rate: 1.5 Gbps hardware minimum physical link rate: 1.5 Gbps programmed maximum physical link rate: 6 Gbps hardware maximum physical link rate: 6 Gbps phy change count: 21 virtual phy: 0 partial pathway timeout value: 7 us routing attribute: table connector type: SAS Drive backplane receptacle (SFF-8482) [max 2 phys] connector element index: 0 connector physical link: 0 phy power condition: 0 sas power capable: 0 sas slumber capable: 0 sas partial capable: 0 sata slumber capable: 0 sata partial capable: 0 pwr_dis signal: 0 pwr_dis control capable: 0 sas slumber enabled: 0 sas partial enabled: 0 sata slumber enabled: 0 sata partial enabled: 0 attached device name: 0x0 requested inside ZPSDS changed by expander: 0 inside ZPSDS persistent: 0 requested inside ZPSDS: 0 zone group persistent: 1 inside ZPSDS: 0 zoning enabled: 0 zone group: 1 self-configuration status: 0 self-configuration levels completed: 0 self-configuration sas address: 0x0 programmed phy capabilities: 0x0 current phy capabilities: 0x0 attached phy capabilities: 0x0 reason: unknown negotiated physical link rate: phy enabled, 6 Gbps optical mode enabled: 0 negotiated SSC: 0 hardware muxing supported: 0 default inside ZPSDS persistent: 0 default requested inside ZPSDS: 0 default zone group persistent: 1 default zoning enabled: 0 default zone group: 1 saved inside ZPSDS persistent: 0 saved requested inside ZPSDS: 0 saved zone group persistent: 1 saved zoning enabled: 0 saved zone group: 1 shadow inside ZPSDS persistent: 0 shadow requested inside ZPSDS: 0 shadow zone group persistent: 1 shadow zoning enabled: 0 shadow zone group: 1 device slot number: 255 device slot group number: 255 device slot group output connector: =20 Discover response: expander change count: 241 phy identifier: 13 attached device type: SAS or SATA device attached reason: unknown negotiated logical link rate: phy enabled, 6 Gbps attached initiator: ssp=3D0 stp=3D0 smp=3D0 sata_host=3D0 attached sata port selector: 0 STP buffer too small: 0 attached target: ssp=3D0 stp=3D0 smp=3D0 sata_device=3D1 SAS address: 0x50030480017bd5bf attached SAS address: 0x50030480017bd5ad attached phy identifier: 0 attached persistent capable: 0 attached power capable: 0 attached slumber capable: 0 attached partial capable: 0 attached inside ZPSDS persistent: 0 attached requested inside ZPSDS: 0 attached break_reply capable: 0 attached pwr_dis capable: 0 programmed minimum physical link rate: 1.5 Gbps hardware minimum physical link rate: 1.5 Gbps programmed maximum physical link rate: 6 Gbps hardware maximum physical link rate: 6 Gbps phy change count: 19 virtual phy: 0 partial pathway timeout value: 7 us routing attribute: table connector type: SAS Drive backplane receptacle (SFF-8482) [max 2 phys] connector element index: 1 connector physical link: 0 phy power condition: 0 sas power capable: 0 sas slumber capable: 0 sas partial capable: 0 sata slumber capable: 0 sata partial capable: 0 pwr_dis signal: 0 pwr_dis control capable: 0 sas slumber enabled: 0 sas partial enabled: 0 sata slumber enabled: 0 sata partial enabled: 0 attached device name: 0x0 requested inside ZPSDS changed by expander: 0 inside ZPSDS persistent: 0 requested inside ZPSDS: 0 zone group persistent: 1 inside ZPSDS: 0 zoning enabled: 0 zone group: 1 self-configuration status: 0 self-configuration levels completed: 0 self-configuration sas address: 0x0 programmed phy capabilities: 0x0 current phy capabilities: 0x0 attached phy capabilities: 0x0 reason: unknown negotiated physical link rate: phy enabled, 6 Gbps optical mode enabled: 0 negotiated SSC: 0 hardware muxing supported: 0 default inside ZPSDS persistent: 0 default requested inside ZPSDS: 0 default zone group persistent: 1 default zoning enabled: 0 default zone group: 1 saved inside ZPSDS persistent: 0 saved requested inside ZPSDS: 0 saved zone group persistent: 1 saved zoning enabled: 0 saved zone group: 1 shadow inside ZPSDS persistent: 0 shadow requested inside ZPSDS: 0 shadow zone group persistent: 1 shadow zoning enabled: 0 shadow zone group: 1 device slot number: 255 device slot group number: 255 device slot group output connector: =20 Discover response: expander change count: 241 phy identifier: 14 attached device type: SAS or SATA device attached reason: unknown negotiated logical link rate: phy enabled, 6 Gbps attached initiator: ssp=3D0 stp=3D0 smp=3D0 sata_host=3D0 attached sata port selector: 0 STP buffer too small: 0 attached target: ssp=3D0 stp=3D0 smp=3D0 sata_device=3D1 SAS address: 0x50030480017bd5bf attached SAS address: 0x50030480017bd5ae attached phy identifier: 0 attached persistent capable: 0 attached power capable: 0 attached slumber capable: 0 attached partial capable: 0 attached inside ZPSDS persistent: 0 attached requested inside ZPSDS: 0 attached break_reply capable: 0 attached pwr_dis capable: 0 programmed minimum physical link rate: 1.5 Gbps hardware minimum physical link rate: 1.5 Gbps programmed maximum physical link rate: 6 Gbps hardware maximum physical link rate: 6 Gbps phy change count: 19 virtual phy: 0 partial pathway timeout value: 7 us routing attribute: table connector type: SAS Drive backplane receptacle (SFF-8482) [max 2 phys] connector element index: 2 connector physical link: 0 phy power condition: 0 sas power capable: 0 sas slumber capable: 0 sas partial capable: 0 sata slumber capable: 0 sata partial capable: 0 pwr_dis signal: 0 pwr_dis control capable: 0 sas slumber enabled: 0 sas partial enabled: 0 sata slumber enabled: 0 sata partial enabled: 0 attached device name: 0x0 requested inside ZPSDS changed by expander: 0 inside ZPSDS persistent: 0 requested inside ZPSDS: 0 zone group persistent: 1 inside ZPSDS: 0 zoning enabled: 0 zone group: 1 self-configuration status: 0 self-configuration levels completed: 0 self-configuration sas address: 0x0 programmed phy capabilities: 0x0 current phy capabilities: 0x0 attached phy capabilities: 0x0 reason: unknown negotiated physical link rate: phy enabled, 6 Gbps optical mode enabled: 0 negotiated SSC: 0 hardware muxing supported: 0 default inside ZPSDS persistent: 0 default requested inside ZPSDS: 0 default zone group persistent: 1 default zoning enabled: 0 default zone group: 1 saved inside ZPSDS persistent: 0 saved requested inside ZPSDS: 0 saved zone group persistent: 1 saved zoning enabled: 0 saved zone group: 1 shadow inside ZPSDS persistent: 0 shadow requested inside ZPSDS: 0 shadow zone group persistent: 1 shadow zoning enabled: 0 shadow zone group: 1 device slot number: 255 device slot group number: 255 device slot group output connector: =20 Discover response: expander change count: 241 phy identifier: 15 attached device type: SAS or SATA device attached reason: unknown negotiated logical link rate: phy enabled, 6 Gbps attached initiator: ssp=3D0 stp=3D0 smp=3D0 sata_host=3D0 attached sata port selector: 0 STP buffer too small: 0 attached target: ssp=3D0 stp=3D0 smp=3D0 sata_device=3D1 SAS address: 0x50030480017bd5bf attached SAS address: 0x50030480017bd5af attached phy identifier: 0 attached persistent capable: 0 attached power capable: 0 attached slumber capable: 0 attached partial capable: 0 attached inside ZPSDS persistent: 0 attached requested inside ZPSDS: 0 attached break_reply capable: 0 attached pwr_dis capable: 0 programmed minimum physical link rate: 1.5 Gbps hardware minimum physical link rate: 1.5 Gbps programmed maximum physical link rate: 6 Gbps hardware maximum physical link rate: 6 Gbps phy change count: 18 virtual phy: 0 partial pathway timeout value: 7 us routing attribute: table connector type: SAS Drive backplane receptacle (SFF-8482) [max 2 phys] connector element index: 3 connector physical link: 0 phy power condition: 0 sas power capable: 0 sas slumber capable: 0 sas partial capable: 0 sata slumber capable: 0 sata partial capable: 0 pwr_dis signal: 0 pwr_dis control capable: 0 sas slumber enabled: 0 sas partial enabled: 0 sata slumber enabled: 0 sata partial enabled: 0 attached device name: 0x0 requested inside ZPSDS changed by expander: 0 inside ZPSDS persistent: 0 requested inside ZPSDS: 0 zone group persistent: 1 inside ZPSDS: 0 zoning enabled: 0 zone group: 1 self-configuration status: 0 self-configuration levels completed: 0 self-configuration sas address: 0x0 programmed phy capabilities: 0x0 current phy capabilities: 0x0 attached phy capabilities: 0x0 reason: unknown negotiated physical link rate: phy enabled, 6 Gbps optical mode enabled: 0 negotiated SSC: 0 hardware muxing supported: 0 default inside ZPSDS persistent: 0 default requested inside ZPSDS: 0 default zone group persistent: 1 default zoning enabled: 0 default zone group: 1 saved inside ZPSDS persistent: 0 saved requested inside ZPSDS: 0 saved zone group persistent: 1 saved zoning enabled: 0 saved zone group: 1 shadow inside ZPSDS persistent: 0 shadow requested inside ZPSDS: 0 shadow zone group persistent: 1 shadow zoning enabled: 0 shadow zone group: 1 device slot number: 255 device slot group number: 255 device slot group output connector: =20 Discover response: expander change count: 241 phy identifier: 16 attached device type: SAS or SATA device attached reason: unknown negotiated logical link rate: phy enabled, 6 Gbps attached initiator: ssp=3D0 stp=3D0 smp=3D0 sata_host=3D0 attached sata port selector: 0 STP buffer too small: 0 attached target: ssp=3D0 stp=3D0 smp=3D0 sata_device=3D1 SAS address: 0x50030480017bd5bf attached SAS address: 0x50030480017bd5b0 attached phy identifier: 0 attached persistent capable: 0 attached power capable: 0 attached slumber capable: 0 attached partial capable: 0 attached inside ZPSDS persistent: 0 attached requested inside ZPSDS: 0 attached break_reply capable: 0 attached pwr_dis capable: 0 programmed minimum physical link rate: 1.5 Gbps hardware minimum physical link rate: 1.5 Gbps programmed maximum physical link rate: 6 Gbps hardware maximum physical link rate: 6 Gbps phy change count: 19 virtual phy: 0 partial pathway timeout value: 7 us routing attribute: table connector type: SAS Drive backplane receptacle (SFF-8482) [max 2 phys] connector element index: 4 connector physical link: 0 phy power condition: 0 sas power capable: 0 sas slumber capable: 0 sas partial capable: 0 sata slumber capable: 0 sata partial capable: 0 pwr_dis signal: 0 pwr_dis control capable: 0 sas slumber enabled: 0 sas partial enabled: 0 sata slumber enabled: 0 sata partial enabled: 0 attached device name: 0x0 requested inside ZPSDS changed by expander: 0 inside ZPSDS persistent: 0 requested inside ZPSDS: 0 zone group persistent: 1 inside ZPSDS: 0 zoning enabled: 0 zone group: 1 self-configuration status: 0 self-configuration levels completed: 0 self-configuration sas address: 0x0 programmed phy capabilities: 0x0 current phy capabilities: 0x0 attached phy capabilities: 0x0 reason: unknown negotiated physical link rate: phy enabled, 6 Gbps optical mode enabled: 0 negotiated SSC: 0 hardware muxing supported: 0 default inside ZPSDS persistent: 0 default requested inside ZPSDS: 0 default zone group persistent: 1 default zoning enabled: 0 default zone group: 1 saved inside ZPSDS persistent: 0 saved requested inside ZPSDS: 0 saved zone group persistent: 1 saved zoning enabled: 0 saved zone group: 1 shadow inside ZPSDS persistent: 0 shadow requested inside ZPSDS: 0 shadow zone group persistent: 1 shadow zoning enabled: 0 shadow zone group: 1 device slot number: 255 device slot group number: 255 device slot group output connector: =20 Discover response: expander change count: 241 phy identifier: 17 attached device type: SAS or SATA device attached reason: unknown negotiated logical link rate: phy enabled, 6 Gbps attached initiator: ssp=3D0 stp=3D0 smp=3D0 sata_host=3D0 attached sata port selector: 0 STP buffer too small: 0 attached target: ssp=3D0 stp=3D0 smp=3D0 sata_device=3D1 SAS address: 0x50030480017bd5bf attached SAS address: 0x50030480017bd5b1 attached phy identifier: 0 attached persistent capable: 0 attached power capable: 0 attached slumber capable: 0 attached partial capable: 0 attached inside ZPSDS persistent: 0 attached requested inside ZPSDS: 0 attached break_reply capable: 0 attached pwr_dis capable: 0 programmed minimum physical link rate: 1.5 Gbps hardware minimum physical link rate: 1.5 Gbps programmed maximum physical link rate: 6 Gbps hardware maximum physical link rate: 6 Gbps phy change count: 18 virtual phy: 0 partial pathway timeout value: 7 us routing attribute: table connector type: SAS Drive backplane receptacle (SFF-8482) [max 2 phys] connector element index: 5 connector physical link: 0 phy power condition: 0 sas power capable: 0 sas slumber capable: 0 sas partial capable: 0 sata slumber capable: 0 sata partial capable: 0 pwr_dis signal: 0 pwr_dis control capable: 0 sas slumber enabled: 0 sas partial enabled: 0 sata slumber enabled: 0 sata partial enabled: 0 attached device name: 0x0 requested inside ZPSDS changed by expander: 0 inside ZPSDS persistent: 0 requested inside ZPSDS: 0 zone group persistent: 1 inside ZPSDS: 0 zoning enabled: 0 zone group: 1 self-configuration status: 0 self-configuration levels completed: 0 self-configuration sas address: 0x0 programmed phy capabilities: 0x0 current phy capabilities: 0x0 attached phy capabilities: 0x0 reason: unknown negotiated physical link rate: phy enabled, 6 Gbps optical mode enabled: 0 negotiated SSC: 0 hardware muxing supported: 0 default inside ZPSDS persistent: 0 default requested inside ZPSDS: 0 default zone group persistent: 1 default zoning enabled: 0 default zone group: 1 saved inside ZPSDS persistent: 0 saved requested inside ZPSDS: 0 saved zone group persistent: 1 saved zoning enabled: 0 saved zone group: 1 shadow inside ZPSDS persistent: 0 shadow requested inside ZPSDS: 0 shadow zone group persistent: 1 shadow zoning enabled: 0 shadow zone group: 1 device slot number: 255 device slot group number: 255 device slot group output connector: =20 Discover response: expander change count: 241 phy identifier: 18 attached device type: SAS or SATA device attached reason: unknown negotiated logical link rate: phy enabled, 6 Gbps attached initiator: ssp=3D0 stp=3D0 smp=3D0 sata_host=3D0 attached sata port selector: 0 STP buffer too small: 0 attached target: ssp=3D0 stp=3D0 smp=3D0 sata_device=3D1 SAS address: 0x50030480017bd5bf attached SAS address: 0x50030480017bd5b2 attached phy identifier: 0 attached persistent capable: 0 attached power capable: 0 attached slumber capable: 0 attached partial capable: 0 attached inside ZPSDS persistent: 0 attached requested inside ZPSDS: 0 attached break_reply capable: 0 attached pwr_dis capable: 0 programmed minimum physical link rate: 1.5 Gbps hardware minimum physical link rate: 1.5 Gbps programmed maximum physical link rate: 6 Gbps hardware maximum physical link rate: 6 Gbps phy change count: 18 virtual phy: 0 partial pathway timeout value: 7 us routing attribute: table connector type: SAS Drive backplane receptacle (SFF-8482) [max 2 phys] connector element index: 6 connector physical link: 0 phy power condition: 0 sas power capable: 0 sas slumber capable: 0 sas partial capable: 0 sata slumber capable: 0 sata partial capable: 0 pwr_dis signal: 0 pwr_dis control capable: 0 sas slumber enabled: 0 sas partial enabled: 0 sata slumber enabled: 0 sata partial enabled: 0 attached device name: 0x0 requested inside ZPSDS changed by expander: 0 inside ZPSDS persistent: 0 requested inside ZPSDS: 0 zone group persistent: 1 inside ZPSDS: 0 zoning enabled: 0 zone group: 1 self-configuration status: 0 self-configuration levels completed: 0 self-configuration sas address: 0x0 programmed phy capabilities: 0x0 current phy capabilities: 0x0 attached phy capabilities: 0x0 reason: unknown negotiated physical link rate: phy enabled, 6 Gbps optical mode enabled: 0 negotiated SSC: 0 hardware muxing supported: 0 default inside ZPSDS persistent: 0 default requested inside ZPSDS: 0 default zone group persistent: 1 default zoning enabled: 0 default zone group: 1 saved inside ZPSDS persistent: 0 saved requested inside ZPSDS: 0 saved zone group persistent: 1 saved zoning enabled: 0 saved zone group: 1 shadow inside ZPSDS persistent: 0 shadow requested inside ZPSDS: 0 shadow zone group persistent: 1 shadow zoning enabled: 0 shadow zone group: 1 device slot number: 255 device slot group number: 255 device slot group output connector: =20 Discover response: expander change count: 241 phy identifier: 19 attached device type: SAS or SATA device attached reason: unknown negotiated logical link rate: phy enabled, 6 Gbps attached initiator: ssp=3D0 stp=3D0 smp=3D0 sata_host=3D0 attached sata port selector: 0 STP buffer too small: 0 attached target: ssp=3D0 stp=3D0 smp=3D0 sata_device=3D1 SAS address: 0x50030480017bd5bf attached SAS address: 0x50030480017bd5b3 attached phy identifier: 0 attached persistent capable: 0 attached power capable: 0 attached slumber capable: 0 attached partial capable: 0 attached inside ZPSDS persistent: 0 attached requested inside ZPSDS: 0 attached break_reply capable: 0 attached pwr_dis capable: 0 programmed minimum physical link rate: 1.5 Gbps hardware minimum physical link rate: 1.5 Gbps programmed maximum physical link rate: 6 Gbps hardware maximum physical link rate: 6 Gbps phy change count: 18 virtual phy: 0 partial pathway timeout value: 7 us routing attribute: table connector type: SAS Drive backplane receptacle (SFF-8482) [max 2 phys] connector element index: 7 connector physical link: 0 phy power condition: 0 sas power capable: 0 sas slumber capable: 0 sas partial capable: 0 sata slumber capable: 0 sata partial capable: 0 pwr_dis signal: 0 pwr_dis control capable: 0 sas slumber enabled: 0 sas partial enabled: 0 sata slumber enabled: 0 sata partial enabled: 0 attached device name: 0x0 requested inside ZPSDS changed by expander: 0 inside ZPSDS persistent: 0 requested inside ZPSDS: 0 zone group persistent: 1 inside ZPSDS: 0 zoning enabled: 0 zone group: 1 self-configuration status: 0 self-configuration levels completed: 0 self-configuration sas address: 0x0 programmed phy capabilities: 0x0 current phy capabilities: 0x0 attached phy capabilities: 0x0 reason: unknown negotiated physical link rate: phy enabled, 6 Gbps optical mode enabled: 0 negotiated SSC: 0 hardware muxing supported: 0 default inside ZPSDS persistent: 0 default requested inside ZPSDS: 0 default zone group persistent: 1 default zoning enabled: 0 default zone group: 1 saved inside ZPSDS persistent: 0 saved requested inside ZPSDS: 0 saved zone group persistent: 1 saved zoning enabled: 0 saved zone group: 1 shadow inside ZPSDS persistent: 0 shadow requested inside ZPSDS: 0 shadow zone group persistent: 1 shadow zoning enabled: 0 shadow zone group: 1 device slot number: 255 device slot group number: 255 device slot group output connector: =20 Discover response: expander change count: 241 phy identifier: 20 attached device type: SAS or SATA device attached reason: unknown negotiated logical link rate: phy enabled, 6 Gbps attached initiator: ssp=3D0 stp=3D0 smp=3D0 sata_host=3D0 attached sata port selector: 0 STP buffer too small: 0 attached target: ssp=3D0 stp=3D0 smp=3D0 sata_device=3D1 SAS address: 0x50030480017bd5bf attached SAS address: 0x50030480017bd5b4 attached phy identifier: 0 attached persistent capable: 0 attached power capable: 0 attached slumber capable: 0 attached partial capable: 0 attached inside ZPSDS persistent: 0 attached requested inside ZPSDS: 0 attached break_reply capable: 0 attached pwr_dis capable: 0 programmed minimum physical link rate: 1.5 Gbps hardware minimum physical link rate: 1.5 Gbps programmed maximum physical link rate: 6 Gbps hardware maximum physical link rate: 6 Gbps phy change count: 18 virtual phy: 0 partial pathway timeout value: 7 us routing attribute: table connector type: SAS Drive backplane receptacle (SFF-8482) [max 2 phys] connector element index: 8 connector physical link: 0 phy power condition: 0 sas power capable: 0 sas slumber capable: 0 sas partial capable: 0 sata slumber capable: 0 sata partial capable: 0 pwr_dis signal: 0 pwr_dis control capable: 0 sas slumber enabled: 0 sas partial enabled: 0 sata slumber enabled: 0 sata partial enabled: 0 attached device name: 0x0 requested inside ZPSDS changed by expander: 0 inside ZPSDS persistent: 0 requested inside ZPSDS: 0 zone group persistent: 1 inside ZPSDS: 0 zoning enabled: 0 zone group: 1 self-configuration status: 0 self-configuration levels completed: 0 self-configuration sas address: 0x0 programmed phy capabilities: 0x0 current phy capabilities: 0x0 attached phy capabilities: 0x0 reason: unknown negotiated physical link rate: phy enabled, 6 Gbps optical mode enabled: 0 negotiated SSC: 0 hardware muxing supported: 0 default inside ZPSDS persistent: 0 default requested inside ZPSDS: 0 default zone group persistent: 1 default zoning enabled: 0 default zone group: 1 saved inside ZPSDS persistent: 0 saved requested inside ZPSDS: 0 saved zone group persistent: 1 saved zoning enabled: 0 saved zone group: 1 shadow inside ZPSDS persistent: 0 shadow requested inside ZPSDS: 0 shadow zone group persistent: 1 shadow zoning enabled: 0 shadow zone group: 1 device slot number: 255 device slot group number: 255 device slot group output connector: =20 Discover response: expander change count: 241 phy identifier: 21 attached device type: SAS or SATA device attached reason: unknown negotiated logical link rate: phy enabled, 6 Gbps attached initiator: ssp=3D0 stp=3D0 smp=3D0 sata_host=3D0 attached sata port selector: 0 STP buffer too small: 0 attached target: ssp=3D0 stp=3D0 smp=3D0 sata_device=3D1 SAS address: 0x50030480017bd5bf attached SAS address: 0x50030480017bd5b5 attached phy identifier: 0 attached persistent capable: 0 attached power capable: 0 attached slumber capable: 0 attached partial capable: 0 attached inside ZPSDS persistent: 0 attached requested inside ZPSDS: 0 attached break_reply capable: 0 attached pwr_dis capable: 0 programmed minimum physical link rate: 1.5 Gbps hardware minimum physical link rate: 1.5 Gbps programmed maximum physical link rate: 6 Gbps hardware maximum physical link rate: 6 Gbps phy change count: 18 virtual phy: 0 partial pathway timeout value: 7 us routing attribute: table connector type: SAS Drive backplane receptacle (SFF-8482) [max 2 phys] connector element index: 9 connector physical link: 0 phy power condition: 0 sas power capable: 0 sas slumber capable: 0 sas partial capable: 0 sata slumber capable: 0 sata partial capable: 0 pwr_dis signal: 0 pwr_dis control capable: 0 sas slumber enabled: 0 sas partial enabled: 0 sata slumber enabled: 0 sata partial enabled: 0 attached device name: 0x0 requested inside ZPSDS changed by expander: 0 inside ZPSDS persistent: 0 requested inside ZPSDS: 0 zone group persistent: 1 inside ZPSDS: 0 zoning enabled: 0 zone group: 1 self-configuration status: 0 self-configuration levels completed: 0 self-configuration sas address: 0x0 programmed phy capabilities: 0x0 current phy capabilities: 0x0 attached phy capabilities: 0x0 reason: unknown negotiated physical link rate: phy enabled, 6 Gbps optical mode enabled: 0 negotiated SSC: 0 hardware muxing supported: 0 default inside ZPSDS persistent: 0 default requested inside ZPSDS: 0 default zone group persistent: 1 default zoning enabled: 0 default zone group: 1 saved inside ZPSDS persistent: 0 saved requested inside ZPSDS: 0 saved zone group persistent: 1 saved zoning enabled: 0 saved zone group: 1 shadow inside ZPSDS persistent: 0 shadow requested inside ZPSDS: 0 shadow zone group persistent: 1 shadow zoning enabled: 0 shadow zone group: 1 device slot number: 255 device slot group number: 255 device slot group output connector: =20 Discover response: expander change count: 241 phy identifier: 22 attached device type: SAS or SATA device attached reason: unknown negotiated logical link rate: phy enabled, 6 Gbps attached initiator: ssp=3D0 stp=3D0 smp=3D0 sata_host=3D0 attached sata port selector: 0 STP buffer too small: 0 attached target: ssp=3D0 stp=3D0 smp=3D0 sata_device=3D1 SAS address: 0x50030480017bd5bf attached SAS address: 0x50030480017bd5b6 attached phy identifier: 0 attached persistent capable: 0 attached power capable: 0 attached slumber capable: 0 attached partial capable: 0 attached inside ZPSDS persistent: 0 attached requested inside ZPSDS: 0 attached break_reply capable: 0 attached pwr_dis capable: 0 programmed minimum physical link rate: 1.5 Gbps hardware minimum physical link rate: 1.5 Gbps programmed maximum physical link rate: 6 Gbps hardware maximum physical link rate: 6 Gbps phy change count: 18 virtual phy: 0 partial pathway timeout value: 7 us routing attribute: table connector type: SAS Drive backplane receptacle (SFF-8482) [max 2 phys] connector element index: 10 connector physical link: 0 phy power condition: 0 sas power capable: 0 sas slumber capable: 0 sas partial capable: 0 sata slumber capable: 0 sata partial capable: 0 pwr_dis signal: 0 pwr_dis control capable: 0 sas slumber enabled: 0 sas partial enabled: 0 sata slumber enabled: 0 sata partial enabled: 0 attached device name: 0x0 requested inside ZPSDS changed by expander: 0 inside ZPSDS persistent: 0 requested inside ZPSDS: 0 zone group persistent: 1 inside ZPSDS: 0 zoning enabled: 0 zone group: 1 self-configuration status: 0 self-configuration levels completed: 0 self-configuration sas address: 0x0 programmed phy capabilities: 0x0 current phy capabilities: 0x0 attached phy capabilities: 0x0 reason: unknown negotiated physical link rate: phy enabled, 6 Gbps optical mode enabled: 0 negotiated SSC: 0 hardware muxing supported: 0 default inside ZPSDS persistent: 0 default requested inside ZPSDS: 0 default zone group persistent: 1 default zoning enabled: 0 default zone group: 1 saved inside ZPSDS persistent: 0 saved requested inside ZPSDS: 0 saved zone group persistent: 1 saved zoning enabled: 0 saved zone group: 1 shadow inside ZPSDS persistent: 0 shadow requested inside ZPSDS: 0 shadow zone group persistent: 1 shadow zoning enabled: 0 shadow zone group: 1 device slot number: 255 device slot group number: 255 device slot group output connector: =20 Discover response: expander change count: 241 phy identifier: 23 attached device type: SAS or SATA device attached reason: unknown negotiated logical link rate: phy enabled, 6 Gbps attached initiator: ssp=3D0 stp=3D0 smp=3D0 sata_host=3D0 attached sata port selector: 0 STP buffer too small: 0 attached target: ssp=3D0 stp=3D0 smp=3D0 sata_device=3D1 SAS address: 0x50030480017bd5bf attached SAS address: 0x50030480017bd5b7 attached phy identifier: 0 attached persistent capable: 0 attached power capable: 0 attached slumber capable: 0 attached partial capable: 0 attached inside ZPSDS persistent: 0 attached requested inside ZPSDS: 0 attached break_reply capable: 0 attached pwr_dis capable: 0 programmed minimum physical link rate: 1.5 Gbps hardware minimum physical link rate: 1.5 Gbps programmed maximum physical link rate: 6 Gbps hardware maximum physical link rate: 6 Gbps phy change count: 18 virtual phy: 0 partial pathway timeout value: 7 us routing attribute: table connector type: SAS Drive backplane receptacle (SFF-8482) [max 2 phys] connector element index: 11 connector physical link: 0 phy power condition: 0 sas power capable: 0 sas slumber capable: 0 sas partial capable: 0 sata slumber capable: 0 sata partial capable: 0 pwr_dis signal: 0 pwr_dis control capable: 0 sas slumber enabled: 0 sas partial enabled: 0 sata slumber enabled: 0 sata partial enabled: 0 attached device name: 0x0 requested inside ZPSDS changed by expander: 0 inside ZPSDS persistent: 0 requested inside ZPSDS: 0 zone group persistent: 1 inside ZPSDS: 0 zoning enabled: 0 zone group: 1 self-configuration status: 0 self-configuration levels completed: 0 self-configuration sas address: 0x0 programmed phy capabilities: 0x0 current phy capabilities: 0x0 attached phy capabilities: 0x0 reason: unknown negotiated physical link rate: phy enabled, 6 Gbps optical mode enabled: 0 negotiated SSC: 0 hardware muxing supported: 0 default inside ZPSDS persistent: 0 default requested inside ZPSDS: 0 default zone group persistent: 1 default zoning enabled: 0 default zone group: 1 saved inside ZPSDS persistent: 0 saved requested inside ZPSDS: 0 saved zone group persistent: 1 saved zoning enabled: 0 saved zone group: 1 shadow inside ZPSDS persistent: 0 shadow requested inside ZPSDS: 0 shadow zone group persistent: 1 shadow zoning enabled: 0 shadow zone group: 1 device slot number: 255 device slot group number: 255 device slot group output connector: =20 Discover response: expander change count: 241 phy identifier: 24 attached device type: no device attached attached reason: unknown negotiated logical link rate: phy disabled attached initiator: ssp=3D0 stp=3D0 smp=3D0 sata_host=3D0 attached sata port selector: 0 STP buffer too small: 0 attached target: ssp=3D0 stp=3D0 smp=3D0 sata_device=3D0 SAS address: 0x50030480017bd5bf attached SAS address: 0x0 attached phy identifier: 0 attached persistent capable: 0 attached power capable: 0 attached slumber capable: 0 attached partial capable: 0 attached inside ZPSDS persistent: 0 attached requested inside ZPSDS: 0 attached break_reply capable: 0 attached pwr_dis capable: 0 programmed minimum physical link rate: 1.5 Gbps hardware minimum physical link rate: 1.5 Gbps programmed maximum physical link rate: 6 Gbps hardware maximum physical link rate: 6 Gbps phy change count: 1 virtual phy: 0 partial pathway timeout value: 7 us routing attribute: direct connector type: No information connector element index: 0 connector physical link: 0 phy power condition: 0 sas power capable: 0 sas slumber capable: 0 sas partial capable: 0 sata slumber capable: 0 sata partial capable: 0 pwr_dis signal: 0 pwr_dis control capable: 0 sas slumber enabled: 0 sas partial enabled: 0 sata slumber enabled: 0 sata partial enabled: 0 attached device name: 0x0 requested inside ZPSDS changed by expander: 0 inside ZPSDS persistent: 0 requested inside ZPSDS: 0 zone group persistent: 1 inside ZPSDS: 0 zoning enabled: 0 zone group: 1 self-configuration status: 0 self-configuration levels completed: 0 self-configuration sas address: 0x0 programmed phy capabilities: 0x0 current phy capabilities: 0x0 attached phy capabilities: 0x0 reason: unknown negotiated physical link rate: phy disabled optical mode enabled: 0 negotiated SSC: 0 hardware muxing supported: 0 default inside ZPSDS persistent: 0 default requested inside ZPSDS: 0 default zone group persistent: 1 default zoning enabled: 0 default zone group: 1 saved inside ZPSDS persistent: 0 saved requested inside ZPSDS: 0 saved zone group persistent: 1 saved zoning enabled: 0 saved zone group: 1 shadow inside ZPSDS persistent: 0 shadow requested inside ZPSDS: 0 shadow zone group persistent: 1 shadow zoning enabled: 0 shadow zone group: 1 device slot number: 255 device slot group number: 255 device slot group output connector: =20 Discover response: expander change count: 241 phy identifier: 25 attached device type: no device attached attached reason: unknown negotiated logical link rate: phy disabled attached initiator: ssp=3D0 stp=3D0 smp=3D0 sata_host=3D0 attached sata port selector: 0 STP buffer too small: 0 attached target: ssp=3D0 stp=3D0 smp=3D0 sata_device=3D0 SAS address: 0x50030480017bd5bf attached SAS address: 0x0 attached phy identifier: 0 attached persistent capable: 0 attached power capable: 0 attached slumber capable: 0 attached partial capable: 0 attached inside ZPSDS persistent: 0 attached requested inside ZPSDS: 0 attached break_reply capable: 0 attached pwr_dis capable: 0 programmed minimum physical link rate: 1.5 Gbps hardware minimum physical link rate: 1.5 Gbps programmed maximum physical link rate: 6 Gbps hardware maximum physical link rate: 6 Gbps phy change count: 1 virtual phy: 0 partial pathway timeout value: 7 us routing attribute: direct connector type: No information connector element index: 0 connector physical link: 0 phy power condition: 0 sas power capable: 0 sas slumber capable: 0 sas partial capable: 0 sata slumber capable: 0 sata partial capable: 0 pwr_dis signal: 0 pwr_dis control capable: 0 sas slumber enabled: 0 sas partial enabled: 0 sata slumber enabled: 0 sata partial enabled: 0 attached device name: 0x0 requested inside ZPSDS changed by expander: 0 inside ZPSDS persistent: 0 requested inside ZPSDS: 0 zone group persistent: 1 inside ZPSDS: 0 zoning enabled: 0 zone group: 1 self-configuration status: 0 self-configuration levels completed: 0 self-configuration sas address: 0x0 programmed phy capabilities: 0x0 current phy capabilities: 0x0 attached phy capabilities: 0x0 reason: unknown negotiated physical link rate: phy disabled optical mode enabled: 0 negotiated SSC: 0 hardware muxing supported: 0 default inside ZPSDS persistent: 0 default requested inside ZPSDS: 0 default zone group persistent: 1 default zoning enabled: 0 default zone group: 1 saved inside ZPSDS persistent: 0 saved requested inside ZPSDS: 0 saved zone group persistent: 1 saved zoning enabled: 0 saved zone group: 1 shadow inside ZPSDS persistent: 0 shadow requested inside ZPSDS: 0 shadow zone group persistent: 1 shadow zoning enabled: 0 shadow zone group: 1 device slot number: 255 device slot group number: 255 device slot group output connector: =20 Discover response: expander change count: 241 phy identifier: 26 attached device type: no device attached attached reason: unknown negotiated logical link rate: phy disabled attached initiator: ssp=3D0 stp=3D0 smp=3D0 sata_host=3D0 attached sata port selector: 0 STP buffer too small: 0 attached target: ssp=3D0 stp=3D0 smp=3D0 sata_device=3D0 SAS address: 0x50030480017bd5bf attached SAS address: 0x0 attached phy identifier: 0 attached persistent capable: 0 attached power capable: 0 attached slumber capable: 0 attached partial capable: 0 attached inside ZPSDS persistent: 0 attached requested inside ZPSDS: 0 attached break_reply capable: 0 attached pwr_dis capable: 0 programmed minimum physical link rate: 1.5 Gbps hardware minimum physical link rate: 1.5 Gbps programmed maximum physical link rate: 6 Gbps hardware maximum physical link rate: 6 Gbps phy change count: 1 virtual phy: 0 partial pathway timeout value: 7 us routing attribute: direct connector type: No information connector element index: 0 connector physical link: 0 phy power condition: 0 sas power capable: 0 sas slumber capable: 0 sas partial capable: 0 sata slumber capable: 0 sata partial capable: 0 pwr_dis signal: 0 pwr_dis control capable: 0 sas slumber enabled: 0 sas partial enabled: 0 sata slumber enabled: 0 sata partial enabled: 0 attached device name: 0x0 requested inside ZPSDS changed by expander: 0 inside ZPSDS persistent: 0 requested inside ZPSDS: 0 zone group persistent: 1 inside ZPSDS: 0 zoning enabled: 0 zone group: 1 self-configuration status: 0 self-configuration levels completed: 0 self-configuration sas address: 0x0 programmed phy capabilities: 0x0 current phy capabilities: 0x0 attached phy capabilities: 0x0 reason: unknown negotiated physical link rate: phy disabled optical mode enabled: 0 negotiated SSC: 0 hardware muxing supported: 0 default inside ZPSDS persistent: 0 default requested inside ZPSDS: 0 default zone group persistent: 1 default zoning enabled: 0 default zone group: 1 saved inside ZPSDS persistent: 0 saved requested inside ZPSDS: 0 saved zone group persistent: 1 saved zoning enabled: 0 saved zone group: 1 shadow inside ZPSDS persistent: 0 shadow requested inside ZPSDS: 0 shadow zone group persistent: 1 shadow zoning enabled: 0 shadow zone group: 1 device slot number: 255 device slot group number: 255 device slot group output connector: =20 Discover response: expander change count: 241 phy identifier: 27 attached device type: no device attached attached reason: unknown negotiated logical link rate: phy disabled attached initiator: ssp=3D0 stp=3D0 smp=3D0 sata_host=3D0 attached sata port selector: 0 STP buffer too small: 0 attached target: ssp=3D0 stp=3D0 smp=3D0 sata_device=3D0 SAS address: 0x50030480017bd5bf attached SAS address: 0x0 attached phy identifier: 0 attached persistent capable: 0 attached power capable: 0 attached slumber capable: 0 attached partial capable: 0 attached inside ZPSDS persistent: 0 attached requested inside ZPSDS: 0 attached break_reply capable: 0 attached pwr_dis capable: 0 programmed minimum physical link rate: 1.5 Gbps hardware minimum physical link rate: 1.5 Gbps programmed maximum physical link rate: 6 Gbps hardware maximum physical link rate: 6 Gbps phy change count: 1 virtual phy: 0 partial pathway timeout value: 7 us routing attribute: direct connector type: No information connector element index: 0 connector physical link: 0 phy power condition: 0 sas power capable: 0 sas slumber capable: 0 sas partial capable: 0 sata slumber capable: 0 sata partial capable: 0 pwr_dis signal: 0 pwr_dis control capable: 0 sas slumber enabled: 0 sas partial enabled: 0 sata slumber enabled: 0 sata partial enabled: 0 attached device name: 0x0 requested inside ZPSDS changed by expander: 0 inside ZPSDS persistent: 0 requested inside ZPSDS: 0 zone group persistent: 1 inside ZPSDS: 0 zoning enabled: 0 zone group: 1 self-configuration status: 0 self-configuration levels completed: 0 self-configuration sas address: 0x0 programmed phy capabilities: 0x0 current phy capabilities: 0x0 attached phy capabilities: 0x0 reason: unknown negotiated physical link rate: phy disabled optical mode enabled: 0 negotiated SSC: 0 hardware muxing supported: 0 default inside ZPSDS persistent: 0 default requested inside ZPSDS: 0 default zone group persistent: 1 default zoning enabled: 0 default zone group: 1 saved inside ZPSDS persistent: 0 saved requested inside ZPSDS: 0 saved zone group persistent: 1 saved zoning enabled: 0 saved zone group: 1 shadow inside ZPSDS persistent: 0 shadow requested inside ZPSDS: 0 shadow zone group persistent: 1 shadow zoning enabled: 0 shadow zone group: 1 device slot number: 255 device slot group number: 255 device slot group output connector: =20 Discover response: expander change count: 241 phy identifier: 28 attached device type: SAS or SATA device attached reason: unknown negotiated logical link rate: phy enabled, 6 Gbps attached initiator: ssp=3D1 stp=3D0 smp=3D1 sata_host=3D0 attached sata port selector: 0 STP buffer too small: 0 attached target: ssp=3D1 stp=3D0 smp=3D0 sata_device=3D0 SAS address: 0x50030480017bd5bf attached SAS address: 0x50030480017bd5bd attached phy identifier: 0 attached persistent capable: 0 attached power capable: 0 attached slumber capable: 0 attached partial capable: 0 attached inside ZPSDS persistent: 0 attached requested inside ZPSDS: 0 attached break_reply capable: 0 attached pwr_dis capable: 0 programmed minimum physical link rate: 6 Gbps hardware minimum physical link rate: 6 Gbps programmed maximum physical link rate: 6 Gbps hardware maximum physical link rate: 6 Gbps phy change count: 1 virtual phy: 1 partial pathway timeout value: 7 us routing attribute: direct connector type: No information connector element index: 0 connector physical link: 0 phy power condition: 0 sas power capable: 0 sas slumber capable: 0 sas partial capable: 0 sata slumber capable: 0 sata partial capable: 0 pwr_dis signal: 0 pwr_dis control capable: 0 sas slumber enabled: 0 sas partial enabled: 0 sata slumber enabled: 0 sata partial enabled: 0 attached device name: 0x0 requested inside ZPSDS changed by expander: 0 inside ZPSDS persistent: 0 requested inside ZPSDS: 0 zone group persistent: 1 inside ZPSDS: 1 zoning enabled: 0 zone group: 1 self-configuration status: 0 self-configuration levels completed: 0 self-configuration sas address: 0x0 programmed phy capabilities: 0x0 current phy capabilities: 0x0 attached phy capabilities: 0x0 reason: unknown negotiated physical link rate: phy enabled, 6 Gbps optical mode enabled: 0 negotiated SSC: 0 hardware muxing supported: 0 default inside ZPSDS persistent: 0 default requested inside ZPSDS: 0 default zone group persistent: 1 default zoning enabled: 0 default zone group: 1 saved inside ZPSDS persistent: 0 saved requested inside ZPSDS: 0 saved zone group persistent: 1 saved zoning enabled: 0 saved zone group: 1 shadow inside ZPSDS persistent: 0 shadow requested inside ZPSDS: 0 shadow zone group persistent: 1 shadow zoning enabled: 0 shadow zone group: 1 device slot number: 255 device slot group number: 255 device slot group output connector: =20 root@rhea:~ #=20 On Dec 5, 2014, at 5:05 PM, Alan Somers wrote: > I had a very similar problem that ended up being a bug in the expander > firmware. It was exposed by the mpr(4) driver because that driver > enumerates drives differently than mps(4) or Linux. Please install > sysutils.smp_utils and post the output of "smp_discover -p $PHY $DEV" > where $DEV is each expander (probably ses0 and ses1) and $PHY is every > phy on each expander. You can see the list of phys by doing > "smp_discover $DEV" without the "-p" option. Also, would you mind > running "sg_inq --hex --len=3D64 $DEV" so I know what we're working > with? >=20 > -Alan >=20