Date: Tue, 15 Oct 2002 14:02:09 -0500 From: "Joseph Moore" <joe@ahpcns.com> To: <questions@freebsd.org> Subject: Compaq RAID - drive replacement - array rebuild problem Message-ID: <HCEFKIHOFAJPLIKJIBALCEACCAAA.joe@ahpcns.com>
next in thread | raw e-mail | index | archive | help
I'm running 4.x STABLE (as of March 2001, aka 4.3RC#0) on a compaq DL380 with integrated RAID (ida0). It had been running flawlessly for over a year until one of the drives failed. I replaced the dead drive (hot-plugged) and re-booted to start the array rebuild process. This was a couple of months ago and the new drive is still flashing it's LEDs to indicate that the rebuild is still underway. I re-booted the box and when the array controller initialized it displayed a message saying that it would "continue the automatic rebuild". How do I get this array rebuild to finish? It's a RAID 1 config with 2, 18GB drives mirrored in hardware. TIA ...jgm To Unsubscribe: send mail to majordomo@FreeBSD.org with "unsubscribe freebsd-questions" in the body of the message
Want to link to this message? Use this URL: <https://mail-archive.FreeBSD.org/cgi/mid.cgi?HCEFKIHOFAJPLIKJIBALCEACCAAA.joe>