Date: Tue, 16 May 2006 17:55:46 -0700 From: John-Mark Gurney <gurney_j@resnet.uoregon.edu> To: Unix-Solutions - Steven <steven@unix-solutions.be> Cc: freebsd-net@freebsd.org Subject: Re: /31 on 2 interfaces Message-ID: <20060517005546.GJ65555@funkthat.com> In-Reply-To: <001301c67946$604b7f70$aa00000a@cloe> References: <001301c67946$604b7f70$aa00000a@cloe>
next in thread | previous in thread | raw e-mail | index | archive | help
Unix-Solutions - Steven wrote this message on Wed, May 17, 2006 at 02:10 +0200:
> I have 2 servers with both 2x 'em' interfaces in it.
> I configged a /31 on both interfaces
> em0 in box 1 = 10.0.0.1
> em0 in box 2 = 10.0.0.2
As someone else mentioned even if you did a /31, those addresses aren't
on the same network...
254 & 1 == 0
254 & 2 == 2
Hence different networks.. the other thing is that you can't have a /31
due to the fact that one ip w/ all the node bits set is the broadcast
for the network causing other sorts of troubles... the smallest usable
network is a /30...
--
John-Mark Gurney Voice: +1 415 225 5579
"All that I will do, has been done, All that I have, has not."