Date: Sat, 23 Jan 2010 13:45:25 +0000 From: krad <kraduk@googlemail.com> To: Dan Naumov <dan.naumov@gmail.com> Cc: freebsd-questions@freebsd.org Subject: Re: Drive errors in raidz array Message-ID: <d36406631001230545i731ecf52mcdbaf05065d217f9@mail.gmail.com> In-Reply-To: <cf9b1ee01001221331pa033dnef517ab9a294faf@mail.gmail.com> References: <cf9b1ee01001221331pa033dnef517ab9a294faf@mail.gmail.com>
next in thread | previous in thread | raw e-mail | index | archive | help
On 22 January 2010 21:31, Dan Naumov <dan.naumov@gmail.com> wrote: > >> I have a system with 24 drives in raidz2. > > Congrats, you answered your own question within the first sentance :) > > ANSWER: As per the ZFS documentation, don't do raidz/raidz2 vdev > groups bigger than 9 vdevs per group or bad things (tm) will happen. > Google will tell you more. > > - Sincerely, > Dan Naumov > _______________________________________________ > freebsd-questions@freebsd.org mailing list > http://lists.freebsd.org/mailman/listinfo/freebsd-questions > To unsubscribe, send any mail to " > freebsd-questions-unsubscribe@freebsd.org" > he didnt actually say that you have inferred it. However you are correct about the vdev size. The best configuration would probably be x2 raidz2 vdevs of 12 drives or 3x of 8. You could also go for 3x raidz of 7 drives with 3 hot spares. It really depends on what redundancy/capacity ratio you want. Having said all this im not convinced the errors you are seeing are definitely due to having 24 drives in a vdev. I would expect some write performance issues and slow rebuild times but not device errors
Want to link to this message? Use this URL: <https://mail-archive.FreeBSD.org/cgi/mid.cgi?d36406631001230545i731ecf52mcdbaf05065d217f9>