Skip site navigation (1)Skip section navigation (2)
Date:      Thu, 28 Apr 2016 17:50:16 +0000 (UTC)
From:      John Baldwin <jhb@FreeBSD.org>
To:        src-committers@freebsd.org, svn-src-all@freebsd.org, svn-src-head@freebsd.org
Subject:   svn commit: r298749 - head/share/man/man9
Message-ID:  <201604281750.u3SHoG1x015773@repo.freebsd.org>

next in thread | raw e-mail | index | archive | help
Author: jhb
Date: Thu Apr 28 17:50:16 2016
New Revision: 298749
URL: https://svnweb.freebsd.org/changeset/base/298749

Log:
  Document PCI_RES_BUS as a possible resource type.

Modified:
  head/share/man/man9/bus_activate_resource.9
  head/share/man/man9/bus_alloc_resource.9

Modified: head/share/man/man9/bus_activate_resource.9
==============================================================================
--- head/share/man/man9/bus_activate_resource.9	Thu Apr 28 17:48:52 2016	(r298748)
+++ head/share/man/man9/bus_activate_resource.9	Thu Apr 28 17:50:16 2016	(r298749)
@@ -28,7 +28,7 @@
 .\"
 .\" $FreeBSD$
 .\"
-.Dd March 28, 2003
+.Dd April 28, 2016
 .Dt BUS_ACTIVATE_RESOURCE 9
 .Os
 .Sh NAME
@@ -65,6 +65,8 @@ The type of resource you want to allocat
 It is one of:
 .Pp
 .Bl -tag -width ".Dv SYS_RES_MEMORY" -compact
+.It Dv PCI_RES_BUS
+for PCI bus numbers
 .It Dv SYS_RES_IRQ
 for IRQs
 .It Dv SYS_RES_DRQ

Modified: head/share/man/man9/bus_alloc_resource.9
==============================================================================
--- head/share/man/man9/bus_alloc_resource.9	Thu Apr 28 17:48:52 2016	(r298748)
+++ head/share/man/man9/bus_alloc_resource.9	Thu Apr 28 17:50:16 2016	(r298749)
@@ -95,6 +95,8 @@ Before allocation, the resource is owned
 is the type of resource you want to allocate.
 It is one of:
 .Bl -tag -width SYS_RES_MEMORY
+.It Dv PCI_RES_BUS
+for PCI bus numbers
 .It Dv SYS_RES_IRQ
 for IRQs
 .It Dv SYS_RES_DRQ
@@ -111,7 +113,7 @@ For ISA this is an index into an array o
 for this device by either the PnP mechanism, or via the hints mechanism.
 For PCCARD, this is an index into the array of resources described by the PC Card's
 CIS entry.
-For PCI, the offset into pci config space which has the BAR to use to access
+For PCI, the offset into PCI config space which has the BAR to use to access
 the resource.
 The bus methods are free to change the RIDs that they are given as a parameter.
 You must not depend on the value you gave it earlier.



Want to link to this message? Use this URL: <https://mail-archive.FreeBSD.org/cgi/mid.cgi?201604281750.u3SHoG1x015773>