From owner-freebsd-stable@FreeBSD.ORG Sat Feb 20 21:50:04 2010 Return-Path: Delivered-To: freebsd-stable@freebsd.org Received: from mx1.freebsd.org (mx1.freebsd.org [IPv6:2001:4f8:fff6::34]) by hub.freebsd.org (Postfix) with ESMTP id 32DEC106566B for ; Sat, 20 Feb 2010 21:50:04 +0000 (UTC) (envelope-from torfinn.ingolfsen@broadpark.no) Received: from bgo1smout1.broadpark.no (bgo1smout1.broadpark.no [217.13.4.94]) by mx1.freebsd.org (Postfix) with ESMTP id A941F8FC17 for ; Sat, 20 Feb 2010 21:50:03 +0000 (UTC) MIME-version: 1.0 Content-type: multipart/mixed; boundary="Boundary_(ID_5X2EXmL0BjmV9PkJJ/E9DA)" Received: from bgo1sminn1.broadpark.no ([217.13.4.93]) by bgo1smout1.broadpark.no (Sun Java(tm) System Messaging Server 6.3-3.01 (built Jul 12 2007; 32bit)) with ESMTP id <0KY5008A6TZEXRB0@bgo1smout1.broadpark.no> for freebsd-stable@freebsd.org; Sat, 20 Feb 2010 22:50:02 +0100 (CET) Received: from kg-v2.kg4.no ([80.203.92.186]) by bgo1sminn1.broadpark.no (Sun Java(tm) System Messaging Server 6.3-3.01 (built Jul 12 2007; 32bit)) with SMTP id <0KY5001W5TZBOJA1@bgo1sminn1.broadpark.no> for freebsd-stable@freebsd.org; Sat, 20 Feb 2010 22:50:02 +0100 (CET) Date: Sat, 20 Feb 2010 22:49:59 +0100 From: Torfinn Ingolfsen To: freebsd-stable@freebsd.org Message-id: <20100220224959.c424dd9e.torfinn.ingolfsen@broadpark.no> In-reply-to: <20100220193718.GA33214@icarus.home.lan> References: <20100131144217.ca08e965.torfinn.ingolfsen@broadpark.no> <20100131175639.86ba9aee.torfinn.ingolfsen@broadpark.no> <20100207163631.da7205fc.torfinn.ingolfsen@broadpark.no> <20100213192404.5e15b5eb.torfinn.ingolfsen@broadpark.no> <20100217091625.d0e74570.torfinn.ingolfsen@broadpark.no> <20100220202108.e1dd1b74.torfinn.ingolfsen@broadpark.no> <20100220193718.GA33214@icarus.home.lan> X-Mailer: Sylpheed 2.7.1 (GTK+ 2.18.7; amd64-portbld-freebsd8.0) X-Face: "t9w2,-X@O^I`jVW\sonI3.,36KBLZE*AL[y9lL[PyFD*r_S:dIL9c[8Y>V42R0"!"yb_zN,f#%.[PYYNq; m"_0v; ~rUM2Yy!zmkh)3&U|u!=T(zyv,MHJv"nDH>OJ`t(@mil461d_B'Uo|'nMwlKe0Mv=kvV?Nh@>Hb<3s_z2jYgZhPb@?Wi^x1a~Hplz1.zH Subject: Re: panic - sleeping thread on FreeBSD 8.0-stable / amd64 X-BeenThere: freebsd-stable@freebsd.org X-Mailman-Version: 2.1.5 Precedence: list List-Id: Production branch of FreeBSD source code List-Unsubscribe: , List-Archive: List-Post: List-Help: List-Subscribe: , X-List-Received-Date: Sat, 20 Feb 2010 21:50:04 -0000 This is a multi-part message in MIME format. --Boundary_(ID_5X2EXmL0BjmV9PkJJ/E9DA) Content-type: text/plain; charset=US-ASCII Content-transfer-encoding: 7BIT On Sat, 20 Feb 2010 11:37:18 -0800 Jeremy Chadwick wrote: > Can you re-run smartctl -a instead of -H? Some of the SMART attributes > may help determine what's going on, or there may be related errors in > the SMART error log. smartctl -a output attached. Test sequence: ad4 - ad12, ada0. > Otherwise I'd say what's happening is a SATA controller lock-up of some > sort, since it happens on any of your channels. Could be a quirk of > some kind in the SATA->CAM stuff (unless it also happens when using pure > ata(4)). I am running a quite recent 8.0-stable: root@kg-f2# uname -a FreeBSD kg-f2.kg4.no 8.0-STABLE FreeBSD 8.0-STABLE #2: Sun Jan 31 18:39:17 CET 2010 root@kg-f2.kg4.no:/usr/obj/usr/src/sys/GENERIC amd64 Perhaps I should upgrade. > What controller are these disks hooked to again? Six of the disks (ad4, ad6, ad8, ad10, ad12) are connected to the SATA ports on the motherboard: root@kg-f2# pciconf -lv | grep ata -A 4 atapci0@pci0:0:17:0: class=0x010601 card=0xb0021458 chip=0x43911002 rev=0x00 hdr=0x00 vendor = 'ATI Technologies Inc. / Advanced Micro Devices, Inc.' device = 'SB700 SATA Controller [AHCI mode]' class = mass storage subclass = SATA -- atapci1@pci0:0:20:1: class=0x01018a card=0x50021458 chip=0x439c1002 rev=0x00 hdr=0x00 vendor = 'ATI Technologies Inc. / Advanced Micro Devices, Inc.' device = 'PATA 133 Controller (SB7xx)' class = mass storage subclass = ATA (There is nothing connected to the PATA ports). The last disk (ada0) is connected to a PCI card: oot@kg-f2# pciconf -lv | grep siis -A 3 siis0@pci0:2:0:0: class=0x018000 card=0x35311095 chip=0x35311095 rev=0x01 hdr=0x00 vendor = 'Silicon Image Inc (Was: CMD Technology Inc)' device = 'SiI 3531 SATA Controller' class = mass storage Hardware info about the machine here: http://sites.google.com/site/tingox/ga-ma74gm-s2h HTH -- Torfinn --Boundary_(ID_5X2EXmL0BjmV9PkJJ/E9DA) Content-type: text/plain; name=f2-smartctl-20100220.txt Content-transfer-encoding: 7BIT Content-disposition: attachment; filename=f2-smartctl-20100220.txt smartctl 5.39 2009-12-09 r2995 [FreeBSD 8.0-STABLE amd64] (local build) Copyright (C) 2002-9 by Bruce Allen, http://smartmontools.sourceforge.net === START OF INFORMATION SECTION === Model Family: SAMSUNG SpinPoint F1 DT series Device Model: SAMSUNG HD252HJ Serial Number: S17HJ9BSA04283 Firmware Version: 1AC01118 User Capacity: 250,059,350,016 bytes Device is: In smartctl database [for details use: -P show] ATA Version is: 8 ATA Standard is: ATA-8-ACS revision 3b Local Time is: Sat Feb 20 22:44:11 2010 CET SMART support is: Available - device has SMART capability. SMART support is: Enabled === START OF READ SMART DATA SECTION === SMART overall-health self-assessment test result: PASSED General SMART Values: Offline data collection status: (0x00) Offline data collection activity was never started. Auto Offline Data Collection: Disabled. Self-test execution status: ( 0) The previous self-test routine completed without error or no self-test has ever been run. Total time to complete Offline data collection: (3651) seconds. Offline data collection capabilities: (0x7b) SMART execute Offline immediate. Auto Offline data collection on/off support. Suspend Offline collection upon new command. Offline surface scan supported. Self-test supported. Conveyance Self-test supported. Selective Self-test supported. SMART capabilities: (0x0003) Saves SMART data before entering power-saving mode. Supports SMART auto save timer. Error logging capability: (0x01) Error logging supported. General Purpose Logging supported. Short self-test routine recommended polling time: ( 2) minutes. Extended self-test routine recommended polling time: ( 62) minutes. Conveyance self-test routine recommended polling time: ( 8) minutes. SCT capabilities: (0x003f) SCT Status supported. SCT Feature Control supported. SCT Data Table supported. SMART Attributes Data Structure revision number: 16 Vendor Specific SMART Attributes with Thresholds: ID# ATTRIBUTE_NAME FLAG VALUE WORST THRESH TYPE UPDATED WHEN_FAILED RAW_VALUE 1 Raw_Read_Error_Rate 0x000f 100 100 051 Pre-fail Always - 0 3 Spin_Up_Time 0x0007 092 092 011 Pre-fail Always - 3260 4 Start_Stop_Count 0x0032 100 100 000 Old_age Always - 21 5 Reallocated_Sector_Ct 0x0033 100 100 010 Pre-fail Always - 0 7 Seek_Error_Rate 0x000f 253 253 051 Pre-fail Always - 0 8 Seek_Time_Performance 0x0025 100 100 015 Pre-fail Offline - 0 9 Power_On_Hours 0x0032 100 100 000 Old_age Always - 1705 10 Spin_Retry_Count 0x0033 100 100 051 Pre-fail Always - 0 11 Calibration_Retry_Count 0x0012 100 100 000 Old_age Always - 0 12 Power_Cycle_Count 0x0032 100 100 000 Old_age Always - 21 13 Read_Soft_Error_Rate 0x000e 100 100 000 Old_age Always - 0 183 Runtime_Bad_Block 0x0032 100 100 000 Old_age Always - 0 184 End-to-End_Error 0x0033 100 100 000 Pre-fail Always - 0 187 Reported_Uncorrect 0x0032 100 100 000 Old_age Always - 0 188 Command_Timeout 0x0032 100 100 000 Old_age Always - 0 190 Airflow_Temperature_Cel 0x0022 068 064 000 Old_age Always - 32 (Lifetime Min/Max 21/32) 194 Temperature_Celsius 0x0022 065 062 000 Old_age Always - 35 (Lifetime Min/Max 21/35) 195 Hardware_ECC_Recovered 0x001a 100 100 000 Old_age Always - 932 196 Reallocated_Event_Count 0x0032 100 100 000 Old_age Always - 0 197 Current_Pending_Sector 0x0012 100 100 000 Old_age Always - 0 198 Offline_Uncorrectable 0x0030 100 100 000 Old_age Offline - 0 199 UDMA_CRC_Error_Count 0x003e 100 100 000 Old_age Always - 0 200 Multi_Zone_Error_Rate 0x000a 100 100 000 Old_age Always - 0 201 Soft_Read_Error_Rate 0x000a 253 253 000 Old_age Always - 0 SMART Error Log Version: 1 No Errors Logged SMART Self-test log structure revision number 1 No self-tests have been logged. [To run self-tests, use: smartctl -t] SMART Selective self-test log data structure revision number 1 SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS 1 0 0 Not_testing 2 0 0 Not_testing 3 0 0 Not_testing 4 0 0 Not_testing 5 0 0 Not_testing Selective self-test flags (0x0): After scanning selected spans, do NOT read-scan remainder of disk. If Selective self-test is pending on power-up, resume after 0 minute delay. smartctl 5.39 2009-12-09 r2995 [FreeBSD 8.0-STABLE amd64] (local build) Copyright (C) 2002-9 by Bruce Allen, http://smartmontools.sourceforge.net === START OF INFORMATION SECTION === Model Family: SAMSUNG SpinPoint F1 DT series Device Model: SAMSUNG HD252HJ Serial Number: S17HJ9BSA04051 Firmware Version: 1AC01118 User Capacity: 250,059,350,016 bytes Device is: In smartctl database [for details use: -P show] ATA Version is: 8 ATA Standard is: ATA-8-ACS revision 3b Local Time is: Sat Feb 20 22:44:20 2010 CET SMART support is: Available - device has SMART capability. SMART support is: Enabled === START OF READ SMART DATA SECTION === SMART overall-health self-assessment test result: PASSED General SMART Values: Offline data collection status: (0x00) Offline data collection activity was never started. Auto Offline Data Collection: Disabled. Self-test execution status: ( 0) The previous self-test routine completed without error or no self-test has ever been run. Total time to complete Offline data collection: (3763) seconds. Offline data collection capabilities: (0x7b) SMART execute Offline immediate. Auto Offline data collection on/off support. Suspend Offline collection upon new command. Offline surface scan supported. Self-test supported. Conveyance Self-test supported. Selective Self-test supported. SMART capabilities: (0x0003) Saves SMART data before entering power-saving mode. Supports SMART auto save timer. Error logging capability: (0x01) Error logging supported. General Purpose Logging supported. Short self-test routine recommended polling time: ( 2) minutes. Extended self-test routine recommended polling time: ( 64) minutes. Conveyance self-test routine recommended polling time: ( 8) minutes. SCT capabilities: (0x003f) SCT Status supported. SCT Feature Control supported. SCT Data Table supported. SMART Attributes Data Structure revision number: 16 Vendor Specific SMART Attributes with Thresholds: ID# ATTRIBUTE_NAME FLAG VALUE WORST THRESH TYPE UPDATED WHEN_FAILED RAW_VALUE 1 Raw_Read_Error_Rate 0x000f 100 100 051 Pre-fail Always - 0 3 Spin_Up_Time 0x0007 092 092 011 Pre-fail Always - 3380 4 Start_Stop_Count 0x0032 100 100 000 Old_age Always - 21 5 Reallocated_Sector_Ct 0x0033 100 100 010 Pre-fail Always - 0 7 Seek_Error_Rate 0x000f 253 253 051 Pre-fail Always - 0 8 Seek_Time_Performance 0x0025 100 100 015 Pre-fail Offline - 0 9 Power_On_Hours 0x0032 100 100 000 Old_age Always - 1705 10 Spin_Retry_Count 0x0033 100 100 051 Pre-fail Always - 0 11 Calibration_Retry_Count 0x0012 100 100 000 Old_age Always - 0 12 Power_Cycle_Count 0x0032 100 100 000 Old_age Always - 21 13 Read_Soft_Error_Rate 0x000e 100 100 000 Old_age Always - 0 183 Runtime_Bad_Block 0x0032 100 100 000 Old_age Always - 0 184 End-to-End_Error 0x0033 100 100 000 Pre-fail Always - 0 187 Reported_Uncorrect 0x0032 100 100 000 Old_age Always - 0 188 Command_Timeout 0x0032 100 100 000 Old_age Always - 0 190 Airflow_Temperature_Cel 0x0022 069 064 000 Old_age Always - 31 (Lifetime Min/Max 22/31) 194 Temperature_Celsius 0x0022 066 063 000 Old_age Always - 34 (Lifetime Min/Max 22/34) 195 Hardware_ECC_Recovered 0x001a 100 100 000 Old_age Always - 1337 196 Reallocated_Event_Count 0x0032 100 100 000 Old_age Always - 0 197 Current_Pending_Sector 0x0012 100 100 000 Old_age Always - 0 198 Offline_Uncorrectable 0x0030 100 100 000 Old_age Offline - 0 199 UDMA_CRC_Error_Count 0x003e 100 100 000 Old_age Always - 0 200 Multi_Zone_Error_Rate 0x000a 100 100 000 Old_age Always - 0 201 Soft_Read_Error_Rate 0x000a 253 253 000 Old_age Always - 0 SMART Error Log Version: 1 No Errors Logged SMART Self-test log structure revision number 1 No self-tests have been logged. [To run self-tests, use: smartctl -t] SMART Selective self-test log data structure revision number 1 SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS 1 0 0 Not_testing 2 0 0 Not_testing 3 0 0 Not_testing 4 0 0 Not_testing 5 0 0 Not_testing Selective self-test flags (0x0): After scanning selected spans, do NOT read-scan remainder of disk. If Selective self-test is pending on power-up, resume after 0 minute delay. smartctl 5.39 2009-12-09 r2995 [FreeBSD 8.0-STABLE amd64] (local build) Copyright (C) 2002-9 by Bruce Allen, http://smartmontools.sourceforge.net === START OF INFORMATION SECTION === Device Model: SAMSUNG HD103SJ Serial Number: S246J1KSB01853 Firmware Version: 1AJ100E4 User Capacity: 1,000,204,886,016 bytes Device is: Not in smartctl database [for details use: -P showall] ATA Version is: 8 ATA Standard is: ATA-8-ACS revision 6 Local Time is: Sat Feb 20 22:44:35 2010 CET SMART support is: Available - device has SMART capability. SMART support is: Enabled === START OF READ SMART DATA SECTION === SMART overall-health self-assessment test result: PASSED General SMART Values: Offline data collection status: (0x00) Offline data collection activity was never started. Auto Offline Data Collection: Disabled. Self-test execution status: ( 0) The previous self-test routine completed without error or no self-test has ever been run. Total time to complete Offline data collection: (9120) seconds. Offline data collection capabilities: (0x5b) SMART execute Offline immediate. Auto Offline data collection on/off support. Suspend Offline collection upon new command. Offline surface scan supported. Self-test supported. No Conveyance Self-test supported. Selective Self-test supported. SMART capabilities: (0x0003) Saves SMART data before entering power-saving mode. Supports SMART auto save timer. Error logging capability: (0x01) Error logging supported. General Purpose Logging supported. Short self-test routine recommended polling time: ( 2) minutes. Extended self-test routine recommended polling time: ( 152) minutes. SCT capabilities: (0x003f) SCT Status supported. SCT Feature Control supported. SCT Data Table supported. SMART Attributes Data Structure revision number: 16 Vendor Specific SMART Attributes with Thresholds: ID# ATTRIBUTE_NAME FLAG VALUE WORST THRESH TYPE UPDATED WHEN_FAILED RAW_VALUE 1 Raw_Read_Error_Rate 0x002f 252 252 051 Pre-fail Always - 0 2 Throughput_Performance 0x0026 252 252 000 Old_age Always - 0 3 Spin_Up_Time 0x0023 073 073 025 Pre-fail Always - 8226 4 Start_Stop_Count 0x0032 100 100 000 Old_age Always - 11 5 Reallocated_Sector_Ct 0x0033 252 252 010 Pre-fail Always - 0 7 Seek_Error_Rate 0x002e 252 252 051 Old_age Always - 0 8 Seek_Time_Performance 0x0024 252 252 015 Old_age Offline - 0 9 Power_On_Hours 0x0032 100 100 000 Old_age Always - 1679 10 Spin_Retry_Count 0x0032 252 252 051 Old_age Always - 0 11 Calibration_Retry_Count 0x0032 252 252 000 Old_age Always - 0 12 Power_Cycle_Count 0x0032 100 100 000 Old_age Always - 12 191 G-Sense_Error_Rate 0x0022 100 100 000 Old_age Always - 1 192 Power-Off_Retract_Count 0x0022 252 252 000 Old_age Always - 0 194 Temperature_Celsius 0x0002 063 061 000 Old_age Always - 37 (Lifetime Min/Max 26/39) 195 Hardware_ECC_Recovered 0x003a 252 252 000 Old_age Always - 0 196 Reallocated_Event_Count 0x0032 252 252 000 Old_age Always - 0 197 Current_Pending_Sector 0x0032 252 252 000 Old_age Always - 0 198 Offline_Uncorrectable 0x0030 252 252 000 Old_age Offline - 0 199 UDMA_CRC_Error_Count 0x0036 200 200 000 Old_age Always - 0 200 Multi_Zone_Error_Rate 0x002a 252 252 000 Old_age Always - 0 223 Load_Retry_Count 0x0032 252 252 000 Old_age Always - 0 225 Load_Cycle_Count 0x0032 100 100 000 Old_age Always - 12 SMART Error Log Version: 1 No Errors Logged SMART Self-test log structure revision number 1 No self-tests have been logged. [To run self-tests, use: smartctl -t] Note: selective self-test log revision number (0) not 1 implies that no selective self-test has ever been run SMART Selective self-test log data structure revision number 0 Note: revision number not 1 implies that no selective self-test has ever been run SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS 1 0 0 Completed [00% left] (0-65535) 2 0 0 Not_testing 3 0 0 Not_testing 4 0 0 Not_testing 5 0 0 Not_testing Selective self-test flags (0x0): After scanning selected spans, do NOT read-scan remainder of disk. If Selective self-test is pending on power-up, resume after 0 minute delay. smartctl 5.39 2009-12-09 r2995 [FreeBSD 8.0-STABLE amd64] (local build) Copyright (C) 2002-9 by Bruce Allen, http://smartmontools.sourceforge.net === START OF INFORMATION SECTION === Device Model: SAMSUNG HD103SJ Serial Number: S246J1KSB01864 Firmware Version: 1AJ100E4 User Capacity: 1,000,204,886,016 bytes Device is: Not in smartctl database [for details use: -P showall] ATA Version is: 8 ATA Standard is: ATA-8-ACS revision 6 Local Time is: Sat Feb 20 22:44:45 2010 CET SMART support is: Available - device has SMART capability. SMART support is: Enabled === START OF READ SMART DATA SECTION === SMART overall-health self-assessment test result: PASSED General SMART Values: Offline data collection status: (0x00) Offline data collection activity was never started. Auto Offline Data Collection: Disabled. Self-test execution status: ( 0) The previous self-test routine completed without error or no self-test has ever been run. Total time to complete Offline data collection: (9300) seconds. Offline data collection capabilities: (0x5b) SMART execute Offline immediate. Auto Offline data collection on/off support. Suspend Offline collection upon new command. Offline surface scan supported. Self-test supported. No Conveyance Self-test supported. Selective Self-test supported. SMART capabilities: (0x0003) Saves SMART data before entering power-saving mode. Supports SMART auto save timer. Error logging capability: (0x01) Error logging supported. General Purpose Logging supported. Short self-test routine recommended polling time: ( 2) minutes. Extended self-test routine recommended polling time: ( 155) minutes. SCT capabilities: (0x003f) SCT Status supported. SCT Feature Control supported. SCT Data Table supported. SMART Attributes Data Structure revision number: 16 Vendor Specific SMART Attributes with Thresholds: ID# ATTRIBUTE_NAME FLAG VALUE WORST THRESH TYPE UPDATED WHEN_FAILED RAW_VALUE 1 Raw_Read_Error_Rate 0x002f 252 252 051 Pre-fail Always - 0 2 Throughput_Performance 0x0026 252 252 000 Old_age Always - 0 3 Spin_Up_Time 0x0023 073 073 025 Pre-fail Always - 8253 4 Start_Stop_Count 0x0032 100 100 000 Old_age Always - 26 5 Reallocated_Sector_Ct 0x0033 252 252 010 Pre-fail Always - 0 7 Seek_Error_Rate 0x002e 252 252 051 Old_age Always - 0 8 Seek_Time_Performance 0x0024 252 252 015 Old_age Offline - 0 9 Power_On_Hours 0x0032 100 100 000 Old_age Always - 1677 10 Spin_Retry_Count 0x0032 252 252 051 Old_age Always - 0 11 Calibration_Retry_Count 0x0032 252 252 000 Old_age Always - 0 12 Power_Cycle_Count 0x0032 100 100 000 Old_age Always - 27 191 G-Sense_Error_Rate 0x0022 252 252 000 Old_age Always - 0 192 Power-Off_Retract_Count 0x0022 252 252 000 Old_age Always - 0 194 Temperature_Celsius 0x0002 063 060 000 Old_age Always - 37 (Lifetime Min/Max 26/40) 195 Hardware_ECC_Recovered 0x003a 252 252 000 Old_age Always - 0 196 Reallocated_Event_Count 0x0032 252 252 000 Old_age Always - 0 197 Current_Pending_Sector 0x0032 252 252 000 Old_age Always - 0 198 Offline_Uncorrectable 0x0030 252 252 000 Old_age Offline - 0 199 UDMA_CRC_Error_Count 0x0036 200 200 000 Old_age Always - 0 200 Multi_Zone_Error_Rate 0x002a 252 252 000 Old_age Always - 0 223 Load_Retry_Count 0x0032 252 252 000 Old_age Always - 0 225 Load_Cycle_Count 0x0032 100 100 000 Old_age Always - 27 SMART Error Log Version: 1 No Errors Logged SMART Self-test log structure revision number 1 No self-tests have been logged. [To run self-tests, use: smartctl -t] Note: selective self-test log revision number (0) not 1 implies that no selective self-test has ever been run SMART Selective self-test log data structure revision number 0 Note: revision number not 1 implies that no selective self-test has ever been run SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS 1 0 0 Completed [00% left] (0-65535) 2 0 0 Not_testing 3 0 0 Not_testing 4 0 0 Not_testing 5 0 0 Not_testing Selective self-test flags (0x0): After scanning selected spans, do NOT read-scan remainder of disk. If Selective self-test is pending on power-up, resume after 0 minute delay. smartctl 5.39 2009-12-09 r2995 [FreeBSD 8.0-STABLE amd64] (local build) Copyright (C) 2002-9 by Bruce Allen, http://smartmontools.sourceforge.net === START OF INFORMATION SECTION === Device Model: SAMSUNG HD103SJ Serial Number: S246J1KSB01865 Firmware Version: 1AJ100E4 User Capacity: 1,000,204,886,016 bytes Device is: Not in smartctl database [for details use: -P showall] ATA Version is: 8 ATA Standard is: ATA-8-ACS revision 6 Local Time is: Sat Feb 20 22:44:57 2010 CET SMART support is: Available - device has SMART capability. SMART support is: Enabled === START OF READ SMART DATA SECTION === SMART overall-health self-assessment test result: PASSED General SMART Values: Offline data collection status: (0x00) Offline data collection activity was never started. Auto Offline Data Collection: Disabled. Self-test execution status: ( 0) The previous self-test routine completed without error or no self-test has ever been run. Total time to complete Offline data collection: (9540) seconds. Offline data collection capabilities: (0x5b) SMART execute Offline immediate. Auto Offline data collection on/off support. Suspend Offline collection upon new command. Offline surface scan supported. Self-test supported. No Conveyance Self-test supported. Selective Self-test supported. SMART capabilities: (0x0003) Saves SMART data before entering power-saving mode. Supports SMART auto save timer. Error logging capability: (0x01) Error logging supported. General Purpose Logging supported. Short self-test routine recommended polling time: ( 2) minutes. Extended self-test routine recommended polling time: ( 159) minutes. SCT capabilities: (0x003f) SCT Status supported. SCT Feature Control supported. SCT Data Table supported. SMART Attributes Data Structure revision number: 16 Vendor Specific SMART Attributes with Thresholds: ID# ATTRIBUTE_NAME FLAG VALUE WORST THRESH TYPE UPDATED WHEN_FAILED RAW_VALUE 1 Raw_Read_Error_Rate 0x002f 252 252 051 Pre-fail Always - 0 2 Throughput_Performance 0x0026 252 252 000 Old_age Always - 0 3 Spin_Up_Time 0x0023 073 073 025 Pre-fail Always - 8213 4 Start_Stop_Count 0x0032 100 100 000 Old_age Always - 26 5 Reallocated_Sector_Ct 0x0033 252 252 010 Pre-fail Always - 0 7 Seek_Error_Rate 0x002e 252 252 051 Old_age Always - 0 8 Seek_Time_Performance 0x0024 252 252 015 Old_age Offline - 0 9 Power_On_Hours 0x0032 100 100 000 Old_age Always - 1676 10 Spin_Retry_Count 0x0032 252 252 051 Old_age Always - 0 11 Calibration_Retry_Count 0x0032 252 252 000 Old_age Always - 0 12 Power_Cycle_Count 0x0032 100 100 000 Old_age Always - 27 191 G-Sense_Error_Rate 0x0022 252 252 000 Old_age Always - 0 192 Power-Off_Retract_Count 0x0022 252 252 000 Old_age Always - 0 194 Temperature_Celsius 0x0002 064 062 000 Old_age Always - 35 (Lifetime Min/Max 25/38) 195 Hardware_ECC_Recovered 0x003a 252 252 000 Old_age Always - 0 196 Reallocated_Event_Count 0x0032 252 252 000 Old_age Always - 0 197 Current_Pending_Sector 0x0032 252 252 000 Old_age Always - 0 198 Offline_Uncorrectable 0x0030 252 252 000 Old_age Offline - 0 199 UDMA_CRC_Error_Count 0x0036 200 200 000 Old_age Always - 0 200 Multi_Zone_Error_Rate 0x002a 252 252 000 Old_age Always - 0 223 Load_Retry_Count 0x0032 252 252 000 Old_age Always - 0 225 Load_Cycle_Count 0x0032 100 100 000 Old_age Always - 27 SMART Error Log Version: 1 No Errors Logged SMART Self-test log structure revision number 1 No self-tests have been logged. [To run self-tests, use: smartctl -t] Note: selective self-test log revision number (0) not 1 implies that no selective self-test has ever been run SMART Selective self-test log data structure revision number 0 Note: revision number not 1 implies that no selective self-test has ever been run SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS 1 0 0 Completed [00% left] (0-65535) 2 0 0 Not_testing 3 0 0 Not_testing 4 0 0 Not_testing 5 0 0 Not_testing Selective self-test flags (0x0): After scanning selected spans, do NOT read-scan remainder of disk. If Selective self-test is pending on power-up, resume after 0 minute delay. smartctl 5.39 2009-12-09 r2995 [FreeBSD 8.0-STABLE amd64] (local build) Copyright (C) 2002-9 by Bruce Allen, http://smartmontools.sourceforge.net === START OF INFORMATION SECTION === Device Model: SAMSUNG HD103SJ Serial Number: S246J1KSB01867 Firmware Version: 1AJ100E4 User Capacity: 1,000,204,886,016 bytes Device is: Not in smartctl database [for details use: -P showall] ATA Version is: 8 ATA Standard is: ATA-8-ACS revision 6 Local Time is: Sat Feb 20 22:45:10 2010 CET SMART support is: Available - device has SMART capability. SMART support is: Enabled === START OF READ SMART DATA SECTION === SMART overall-health self-assessment test result: PASSED General SMART Values: Offline data collection status: (0x00) Offline data collection activity was never started. Auto Offline Data Collection: Disabled. Self-test execution status: ( 0) The previous self-test routine completed without error or no self-test has ever been run. Total time to complete Offline data collection: (9420) seconds. Offline data collection capabilities: (0x5b) SMART execute Offline immediate. Auto Offline data collection on/off support. Suspend Offline collection upon new command. Offline surface scan supported. Self-test supported. No Conveyance Self-test supported. Selective Self-test supported. SMART capabilities: (0x0003) Saves SMART data before entering power-saving mode. Supports SMART auto save timer. Error logging capability: (0x01) Error logging supported. General Purpose Logging supported. Short self-test routine recommended polling time: ( 2) minutes. Extended self-test routine recommended polling time: ( 157) minutes. SCT capabilities: (0x003f) SCT Status supported. SCT Feature Control supported. SCT Data Table supported. SMART Attributes Data Structure revision number: 16 Vendor Specific SMART Attributes with Thresholds: ID# ATTRIBUTE_NAME FLAG VALUE WORST THRESH TYPE UPDATED WHEN_FAILED RAW_VALUE 1 Raw_Read_Error_Rate 0x002f 252 252 051 Pre-fail Always - 0 2 Throughput_Performance 0x0026 252 252 000 Old_age Always - 0 3 Spin_Up_Time 0x0023 073 073 025 Pre-fail Always - 8183 4 Start_Stop_Count 0x0032 100 100 000 Old_age Always - 8 5 Reallocated_Sector_Ct 0x0033 252 252 010 Pre-fail Always - 0 7 Seek_Error_Rate 0x002e 252 252 051 Old_age Always - 0 8 Seek_Time_Performance 0x0024 252 252 015 Old_age Offline - 0 9 Power_On_Hours 0x0032 100 100 000 Old_age Always - 1679 10 Spin_Retry_Count 0x0032 252 252 051 Old_age Always - 0 11 Calibration_Retry_Count 0x0032 252 252 000 Old_age Always - 0 12 Power_Cycle_Count 0x0032 100 100 000 Old_age Always - 12 191 G-Sense_Error_Rate 0x0022 100 100 000 Old_age Always - 1 192 Power-Off_Retract_Count 0x0022 252 252 000 Old_age Always - 0 194 Temperature_Celsius 0x0002 064 064 000 Old_age Always - 33 (Lifetime Min/Max 22/35) 195 Hardware_ECC_Recovered 0x003a 252 252 000 Old_age Always - 0 196 Reallocated_Event_Count 0x0032 252 252 000 Old_age Always - 0 197 Current_Pending_Sector 0x0032 252 252 000 Old_age Always - 0 198 Offline_Uncorrectable 0x0030 252 252 000 Old_age Offline - 0 199 UDMA_CRC_Error_Count 0x0036 200 200 000 Old_age Always - 0 200 Multi_Zone_Error_Rate 0x002a 252 252 000 Old_age Always - 0 223 Load_Retry_Count 0x0032 252 252 000 Old_age Always - 0 225 Load_Cycle_Count 0x0032 100 100 000 Old_age Always - 12 SMART Error Log Version: 1 No Errors Logged SMART Self-test log structure revision number 1 No self-tests have been logged. [To run self-tests, use: smartctl -t] Note: selective self-test log revision number (0) not 1 implies that no selective self-test has ever been run SMART Selective self-test log data structure revision number 0 Note: revision number not 1 implies that no selective self-test has ever been run SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS 1 0 0 Completed [00% left] (0-65535) 2 0 0 Not_testing 3 0 0 Not_testing 4 0 0 Not_testing 5 0 0 Not_testing Selective self-test flags (0x0): After scanning selected spans, do NOT read-scan remainder of disk. If Selective self-test is pending on power-up, resume after 0 minute delay. --Boundary_(ID_5X2EXmL0BjmV9PkJJ/E9DA)--