On Wed, 16 May 2001, Clemens Hermann wrote:

> today I installed a mylex AcceleRaid 170 on FreeBSD 4.3 Release. I
> have two mirrors which worked right out of the box (da0/da1). The
> only problem: when I boot the system I get the following messages:
>
> mly0: physical device 0:6 gone
> mly0: physical device 0:6 gone
> mly0: enclosure 6 unit 0 access offlinemly0: physical device 0:6 gone
> mly0: physical device 0:6 gone
>
> There does no such disk exist, according to the controller-setup
> this is the processor. Are these messages a problem?

Shouldn't be.  I had problems with the enclosure management processor
on the system I'm using, but Mike Smith fixed the mly driver recently
and alleviated the problem.  That fix should be in 4.3-RELEASE, I
believe.


> Furthermore:
> - How can I check the status of the controller/devices?
> - How will I know when a drive fails?
> - do any userland tools exist?
> - is there any docu available?

No userland tools exist yet to manage the controller and its devices,
that I know of.  With a managed hot-plug enclosure, I'm not sure that
you would even need any.  I do know that the driver (via the kernel)
will emit a warning when a RAID array goes critical.  You can test it
yourself by simply removing a drive from your redundant array,
assuming you have a hot-plug setup.  I've done this to test things
out, and it works great.  As long as you have the controller set up to
do automatic rebuilds you should only have to replace the drive and
wait for the array to be rebuilt.  Once that is done, you will be
notified when the array is optimal again.

Here is some dmesg output from a system that booted up with a drive
missing from its RAID array, and then automatically rebuilt the array
when I inserted the new drive, all while the system was going about
its normal business:

mly0: <Mylex AcceleRAID 170> mem 0xfc5fe000-0xfc5fffff irq 10 at device 1.1 on pci2
mly0: AcceleRAID 170  , 1 channel, firmware 6.00-7-00 (20001214), 32MB RAM
da0 at mly0 bus 1 target 0 lun 0
da0: <RAID 1 critical > Fixed Direct Access SCSI-3 device
da0: 135.168MB/s transfers
da0: 17480MB (35799040 512 byte sectors: 255H 63S/T 2228C)
[ The system is booted and multiuser.  Now, I insert the replacement
drive...]
mly0: physical device 0:1  found
mly0: physical device 0:1  automatic rebuild started
mly0: logical device 0 (da0)  automatic rebuild started
[ Many minutes pass while the array is rebuilt... ]
mly0: logical device 0 (da0)  rebuild completed
mly0: physical device 0:1  rebuild completed
mly0: physical device 0:1  online
mly0: logical device 0 (da0)  online


-- Chris Dillon - cdillon@wolves.k12.mo.us - cdillon@inter-linc.net
   FreeBSD: The fastest and most stable server OS on the planet.
   For IA32 and Alpha architectures. IA64, PPC, and ARM under development.
   http://www.freebsd.org



To Unsubscribe: send mail to majordomo@FreeBSD.org
with "unsubscribe freebsd-scsi" in the body of the message




Want to link to this message? Use this URL: <https://mail-archive.FreeBSD.org/cgi/mid.cgi?Pine.BSF.4.32.0105161533341.2129-100000>