Date: Fri, 01 Jun 2007 14:29:32 -0400 From: "Brian A. Seklecki" <bseklecki@collaborativefusion.com> To: patch@Zabbadoz.NeT, freebsd-questions@freebsd.org Cc: lavalamp@spiritual-machines.org Subject: Re: megacli and PERC5 (PowerEdge 1950) on 6.2 Message-ID: <1180722572.30575.8.camel@soundwave.pgh.priv.collaborativefusion.com>
next in thread | raw e-mail | index | archive | help
I'm buying free beer in unsound quantities for the commiter of this patch. And for the author, well... that's best discussed offline >:} [seklecki@db06 ~]$ sudo megacli -AdpAllInfo -aALL Password: Adapter #0 ============================================================================== Versions ================ Product Name : PERC 5/i Integrated Serial No : 12345 FW Package Build: 5.1.1-0040 FW Version : 1.03.10-0216 BIOS Version : MT28 Ctrl-R Version :1.04-017A Pending Images In Flash ================ None PCI Info ================ Vendor Id : 1028 Device Id : 0015 SubVendorId : 1028 SubDeviceId : 1f03 Host Interface : PCIE Number of Frontend Port: 0 Device Interface : PCIE Number of Backend Port: 8 Port : Address 0 5000c500005dad19 1 5000c500005da6e9 2 5000c50001cf9301 3 5000c50001cfb2c1 4 5000c500049065cd 5 5000c50001cf9d61 6 0000000000000000 7 0000000000000000 HW Configuration ================ SAS Address : 50019b90cb771f00 BBU : Present Alarm : Absent NVRAM : Present Serial Debugger : Present Memory : Present Flash : Present Settings ================ Current Time : 14:26:27 6/1, 2007 Predictive Fail Poll Interval : 300sec Interrupt Throttle Active Count : 16 Interrupt Throttle Completion : 50us Rebuild Rate : 30% PR Rate : 30% Resynch Rate : 30% Check Consistency Rate : 30% Reconstruction Rate : 30% Cache flush interval : 4s Max drives to spinup at one time : 2 Delay among spinup groups : 12s Physical drive coercion mode : 128MB Cluster mode : Disabled Alarm : Disabled Auto Rebuild : Enabled Battery Warning : Enabled Ecc Bucket Size : 15 Ecc Bucket Leak Rate : 1440 Minutes Restore HotSpare On Insertion : Disabled Expose Enclosure Devices : Disabled Maintain PD Fail History : Disabled Host Request Reordering : Enabled Capabilities ================ RAID Level Supported : RAID0, RAID1, RAID5, RAID10, RAID50 Supported Drives : SAS, SATA Allowed Mixing: Mix In Enclosure Allowed Status ================ ECC Bucket Count : 0 Limitations ================ Max Arms Per VD : 32 Max Spans Per VD : 8 Max Arrays : 128 Max Number of VDs : 64 Max Parallel Commands : 1008 Max SGE Count : 80 Max Data Transfer Size : 8192 sectors Max Strips PerIO : 84 Min Stripe Size : 8kB Max Stripe Size : 128kB Device Present ================ Virtual Drives : 2 Degraded : 0 Offline : 0 Physical Devices : 7 Disks : 6 Critical Disks : 0 Failed Disks : 0 Supported Adapter Operations ================ Rebuild Rate : Yes CC Rate : Yes BGI Rate : Yes Reconstruct Rate : Yes Patrol Read Rate : Yes Alarm Control : Yes Cluster Support : No BBU : Yes Spanning : Yes Dedicated Hot Spare : Yes revertible Hot Spares : No Foreign Config Import : Yes Self Diagnostic : Yes Allow Mixed Redundancy On Array : No Global Hot Spares : Yes Deny SCSI Passthrough : No Deny SMP Passthrough : No Deny STP Passthrough : No Supported VD Operations ================ Read Policy : Yes Write Policy : Yes IO Policy : Yes Access Policy : Yes Disk Cache Policy : Yes Reconstruction : Yes Deny Locate : No Deny CC : No Supported PD Operations ================ Force Online : Yes Force Offline : Yes Force Rebuild : Yes Deny Force Failed : No Deny Force Good/Bad : No Deny Missing Replace : No Deny Clear : No Deny Locate : No Error Counters ================ Memory Correctable Errors : 0 Memory Uncorrectable Errors : 0 Cluster Information ================ Cluster Permitted : No Cluster Active : No Default Settings ================ Phy Polarity : 0 Phy PolaritySplit : 0 Backgroud Rate : 30 Stripe Size : 64kB Flush Time : 4 seconds Write Policy : WB Read Policy : None Cache When BBU Bad : Disabled Cached IO : No SMART Mode : Mode 6 Alarm Disable : No Coercion Mode : 128MB ZCR Config : IDSEL Dirty LED Shows Drive Activity : No BIOS Continue On Error : No Spin Down Mode : None Allowed Device Type : SAS/SATA Mix Allow Mix In Enclosure : Yes Allow Mix In VD : No Allow SATA In Cluster : No Max Chained Enclosures : 1 Disable Ctrl-R : No Enable Web BIOS : No Direct PD Mapping : No BIOS Enumerate VDs : No Restore Hot Spare On Insertion : No Expose Enclosure Devices : No Maintain PD Fail History : No -- Brian A. Seklecki <bseklecki@collaborativefusion.com> Collaborative Fusion, Inc. IMPORTANT: This message contains confidential information and is intended only for the individual named. If the reader of this message is not an intended recipient (or the individual responsible for the delivery of this message to an intended recipient), please be advised that any re-use, dissemination, distribution or copying of this message is prohibited. Please notify the sender immediately by e-mail if you have received this e-mail by mistake and delete this e-mail from your system.
Want to link to this message? Use this URL: <https://mail-archive.FreeBSD.org/cgi/mid.cgi?1180722572.30575.8.camel>