Skip site navigation (1)Skip section navigation (2)
Date:      Mon, 7 Sep 1998 23:57:04 +0200
From:      Ollivier Robert <roberto@keltia.freenix.fr>
To:        vallo@matti.ee, freebsd-scsi@FreeBSD.ORG
Subject:   Re: ncr: frequent ccb errors and crashes
Message-ID:  <19980907235704.A25023@keltia.freenix.fr>
In-Reply-To: <19980907204248.43962@matti.ee>; from Vallo Kallaste on Mon, Sep 07, 1998 at 08:42:48PM %2B0300
References:  <19980907204248.43962@matti.ee>

next in thread | previous in thread | raw e-mail | index | archive | help
> this problem is known incompatability between Quantum drives and Sym.Logic 
> controllers ? I think so, because with Adaptec controller all this just 
> works.  

That could be the reason. The only thing I can say is that I've been using
wto ASUS adapters in my machine for years (one SC-875 and one SC-200)
without a single problem...

ncr0: <ncr 53c875 fast20 wide scsi> rev 0x03 int a irq 9 on pci0.11.0
scbus0 at ncr0 bus 0
sd0 at scbus0 target 0 lun 0
sd0: <IBM DCAS-34330W S65A> type 0 fixed SCSI 2
sd0: Direct-Access 
sd0: WIDE SCSI (16 bit) enabled
sd0: 40.0 MB/s (50 ns, offset 15)
4134MB (8467200 512 byte sectors)
sd1 at scbus0 target 1 lun 0
sd1: <IBM DCAS-34330W S65A> type 0 fixed SCSI 2
sd1: Direct-Access 
sd1: WIDE SCSI (16 bit) enabled
sd1: 40.0 MB/s (50 ns, offset 15)
4134MB (8467200 512 byte sectors)
sd2 at scbus0 target 2 lun 0
sd2: <IBM DORS-32160 WA6A> type 0 fixed SCSI 2
sd2: Direct-Access 
sd2: 20.0 MB/s (50 ns, offset 15)
2063MB (4226725 512 byte sectors)
st1 at scbus0 target 4 lun 0
st1: <TANDBERG  TDC 3600 =08:> type 1 removable SCSI 2
st1: Sequential-Access density code 0x0,  drive empty

ncr1: <ncr 53c810a fast10 scsi> rev 0x12 int a irq 11 on pci0.12.0
scbus1 at ncr1 bus 0
sd12 at scbus1 target 2 lun 0
sd12: <CONNER CFP1080S 3939> type 0 fixed SCSI 2
sd12: Direct-Access 
sd12: 10.0 MB/s (100 ns, offset 8)
1030MB (2110812 512 byte sectors)
cd1 at scbus1 target 3 lun 0
cd1: <SONY CD-ROM CDU-415 1.1i> type 5 removable SCSI 2
cd1: CD-ROM 
cd1: 10.0 MB/s (100 ns, offset 8)
cd present [400000 x 2048 byte records]
st0 at scbus1 target 5 lun 0
st0: <HP HP35480A 1009> type 1 removable SCSI 2
st0: Sequential-Access 
st0: 5.0 MB/s (200 ns, offset 8)
density code 0x13,  drive empty

-- 
Ollivier ROBERT -=- FreeBSD: The Power to Serve! -=- roberto@keltia.freenix.fr
FreeBSD keltia.freenix.fr 3.0-CURRENT #63: Tue Sep  1 00:50:29 CEST 1998


To Unsubscribe: send mail to majordomo@FreeBSD.org
with "unsubscribe freebsd-scsi" in the body of the message



Want to link to this message? Use this URL: <https://mail-archive.FreeBSD.org/cgi/mid.cgi?19980907235704.A25023>