Skip site navigation (1)Skip section navigation (2)
Date:      Mon, 15 Apr 2002 16:08:43 -0500
From:      Patrick Hartling <patrick@137.org>
To:        Bernd Walter <ticso@cicely9.cicely.de>
Cc:        freebsd-current@FreeBSD.ORG
Subject:   Re: Vinum problems
Message-ID:  <3CBB415B.40604@137.org>
References:  <3CB763C5.8070200@137.org> <20020413175332.GD10043@cicely9.cicely.de>

next in thread | previous in thread | raw e-mail | index | archive | help
Bernd,
	This sounds very promising, but I want to make sure I do this correctly. 
When you say to remove the plexes, that means to use 'vinum rm' with 
appropriate options, correct?  As far as reconfiguring, can I use the 
output from 'vinum printconfig' as the input configuration file?
	Thanks very much for your help.

  -Patrick

Bernd Walter wrote:
> On Fri, Apr 12, 2002 at 05:46:29PM -0500, Patrick Hartling wrote:
> 
>>I suffered a system crash earlier today running -current from April 10. 
>> I have a Vinum volume set up as a mirror, and during the reboot, I had 
>>to fsck it.  Everything seemed normal (at least that's what I thought), 
>>but now my volume cannot be mounted.  The output from 'vinum list' is as 
>>follows:
>>
>>2 drives:
>>D a                     State: up       /dev/da3s1e     A: 0/12288 MB (0%)
>>D b                     State: up       /dev/da4s1e     A: 0/12288 MB (0%)
>>
>>1 volumes:
>>V mirror                State: down     Plexes:       2 Size:         11 GB
>>
>>2 plexes:
>>P mirror.p0           C State: faulty   Subdisks:     1 Size:         11 GB
>>P mirror.p1           C State: faulty   Subdisks:     1 Size:         11 GB
>>
>>2 subdisks:
>>S mirror.p0.s0          State: crashed  D: a            Size:         11 GB
>>S mirror.p1.s0          State: crashed  D: b            Size:         11 GB
>>
>>The fact that it says the drives have 0% used greatly concerns me. 
>>Before I delve into this any further, is that a sign that everything I 
>>had is just gone?  Or is there some hope of recovery?  There is nothing 
>>in /var/log/vinum_hitsory or /var/log/messages that gives me any insight 
>>into what went wrong.
> 
> 
> You have *both* plexes faulty which means that you either have waited
> too long running with only one disk left or that both failed a once.
> For the second point can be channel or power supply issues if they
> share a single resource in common.
> You will find it out by reading your log files.
> Of course you should fix the failure reason before doing anything else.
> 
> I have made a bad expirience once in that if you revive one plex
> now you will get zeros written because there is no reference plex left.
> Greg: It's long ago but I forgot to tell you.
>       Do you remember anything about such a bug got fixed?
> 
> The shure way is to store the vinum printconfig output and then
> remove both plexes.
> finaly reconfigure them both beginning using the values from printconfig
> and start with the drive which run at last, because it has the most
> recent data.
> 



-- 
Patrick L. Hartling                     | Research Assistant, VRAC
patrick@137.org                         | 2624 Howe Hall -- (515)294-4916
http://www.137.org/patrick/             | http://www.vrac.iastate.edu/


To Unsubscribe: send mail to majordomo@FreeBSD.org
with "unsubscribe freebsd-current" in the body of the message




Want to link to this message? Use this URL: <https://mail-archive.FreeBSD.org/cgi/mid.cgi?3CBB415B.40604>