From owner-freebsd-questions Thu May 17 20:56:43 2001 Delivered-To: freebsd-questions@freebsd.org Received: from homer.futureuse.net (CPE-61-9-146-167.vic.bigpond.net.au [61.9.146.167]) by hub.freebsd.org (Postfix) with SMTP id A2E3437B42C for ; Thu, 17 May 2001 20:56:39 -0700 (PDT) (envelope-from fbsdlist@futureuse.net) Received: (qmail 76760 invoked by uid 65534); 3 May 2001 03:57:17 -0000 Received: from 203.11.225.5 (SquirrelMail authenticated user fbsdlist) by www.futureuse.net with HTTP; Thu, 3 May 2001 13:57:17 +1000 (EST) Message-ID: <57746.203.11.225.5.988862237.squirrel@www.futureuse.net> Date: Thu, 3 May 2001 13:57:17 +1000 (EST) Subject: Re: ida0: soft error ? From: "Aaron Hill" To: bill@carracing.com In-Reply-To: References: Cc: freebsd-questions@FreeBSD.ORG X-Mailer: SquirrelMail (version 1.0.5) MIME-Version: 1.0 Content-Type: text/plain; charset=iso-8859-1 Content-Transfer-Encoding: 8bit Sender: owner-freebsd-questions@FreeBSD.ORG Precedence: bulk List-ID: X-Loop: FreeBSD.ORG > Hello, Hello. > I have a copmpaq 2500 with a smart-2/p array controller and 5 9gig > drives. I've got an older Compaq but also with the SMART-2/P. I've currently got a dead drive in that machine and so I'm also seeing numerous soft errors. today the controller reported that one of the drives had > an 'iminent failure' that was going to happen to one of them. I > replaced that drive with another drive that has not previously given > problems, and since installing it, I get tons of ida0: soft error. from > what I did see in the archives, a soft error appears to be when the > controller tries to write to the disk and is unsuccessful the first > time, but a 2nd try works. Is this the case? if so, is it due to the > new drive rebuilding and does that error go away after the rebuilding > process? As I understand it you get a soft error when your system makes a request of the drive array and to fulfill the request the adapter has to use the RAID function instead of reading directly from disk. So you get an error, but calling it a soft error means that something is wrong but the array is still functioning. The soft errors will go away after the array has been rebuilt onto the new disk. > If it doesnt go away after the rebuilding process, where do I > look to diagnose the problem? Do you have a Compaq SmartStart CD? If so boot off that and running the Array Diagnostic Utility. However when you reboot the server you will probably be told by the array adapter at initialisation that array X needs to be rebuilt. If you choose the Automatic Recovery option that it presents you can happily boot back into FreeBSD and the OS will run while the array is rebuilt - albeit with some soft errors. Aaron Hill To Unsubscribe: send mail to majordomo@FreeBSD.org with "unsubscribe freebsd-questions" in the body of the message