today SSD are really fast and quite cheap, but still hard drives are many times cheaper. Magnetic hard drives are OK in long reads anyway, just bad on seeks. While now it's trendy to use ZFS i would stick to UFS anyway. I try to keep most of data on HDDs but use SSD for small files and high I/O needs. It works but needs to much manual and semi automated work. It would be better to just use HDD for storage and some of SSD for cache and other for temporary storage only. My idea is to make geom layer for caching one geom provider (magnetic disk/partition or gmirror/graid5) using other geom provider (SSD partition). I have no experience in writing geom layer drivers but i think geom_cache would be my fine starting point. At first i would do read/write through caching. Writeback caching would be next - if at all, doesn't seem good idea except you are sure SSD won't fail. But my question is really on UFS. I would like to know in geom layer if read/write operation is inode/directory/superblock write or regular data write - so i would give the first time higher priority. Regular data would not be cached at all, or only when read size will be less than defined value. Is it possible to modify UFS code to pass somehow a flag/value when issuing read/write request to device layer?