Date: Sun, 03 Oct 1999 18:34:32 -0700 From: John Barbee <jbarbee@singular.com> To: freebsd-questions@freebsd.org Subject: vinum: faulty plex Message-ID: <4.1.19991003175604.00aa52c0@server7.singular.com>
next in thread | raw e-mail | index | archive | help
hi,
i set up vinum about a week ago. i left it alone and just got back on
track today. i imagine if things really are working one of my plexes
wouldn't be faulty. i did a reset config but i still have a faulty plex.
here is some output. did i do something wrong or is it one of my drives.
silence# cat log
NO VINOsilence.blackmist.orgsd0+89
,8Vvolume mirror state up
plex name mirror.p0 state up org concat vol mirror
plex name mirror.p1 state faulty org concat vol mirror
sd name mirror.p0.s0 drive sd0 state up len 4194304s driveoffset 265s plex
mirror.p0 plexoffset 0s
sd name mirror.p0.s1 drive sd1 state up len 4194304s driveoffset 265s plex
mirror.p0 plexoffset 4194304s
sd name mirror.p1.s0 drive sd2 state reviving len 4194304s driveoffset 265s
plex mirror.p1 plexoffset 0s
sd name mirror.p1.s1 drive sd3 state reviving len 4194304s driveoffset 265s
plex mirror.p1 plexoffset 4194304s
NO VINOsilence.blackmist.orgsd1+8Q
,8
volume mirror state up
plex name mirror.p0 state up org concat vol mirror
plex name mirror.p1 state faulty org concat vol mirror
sd name mirror.p0.s0 drive sd0 state up len 4194304s driveoffset 265s plex
mirror.p0 plexoffset 0s
sd name mirror.p0.s1 drive sd1 state up len 4194304s driveoffset 265s plex
mirror.p0 plexoffset 4194304s
sd name mirror.p1.s0 drive sd2 state reviving len 4194304s driveoffset 265s
plex mirror.p1 plexoffset 0s
sd name mirror.p1.s1 drive sd3 state reviving len 4194304s driveoffset 265s
plex mirror.p1 plexoffset 4194304s
NO VINOsilence.blackmist.orgsd2+8
,8
volume mirror state up
plex name mirror.p0 state up org concat vol mirror
plex name mirror.p1 state faulty org concat vol mirror
sd name mirror.p0.s0 drive sd0 state up len 4194304s driveoffset 265s plex
mirror.p0 plexoffset 0s
sd name mirror.p0.s1 drive sd1 state up len 4194304s driveoffset 265s plex
mirror.p0 plexoffset 4194304s
sd name mirror.p1.s0 drive sd2 state reviving len 4194304s driveoffset 265s
plex mirror.p1 plexoffset 0s
sd name mirror.p1.s1 drive sd3 state reviving len 4194304s driveoffset 265s
plex mirror.p1 plexoffset 4194304s
NO VINOsilence.blackmist.orgsd3+8
,85volume mirror state up
plex name mirror.p0 state up org concat vol mirror
plex name mirror.p1 state faulty org concat vol mirror
sd name mirror.p0.s0 drive sd0 state up len 4194304s driveoffset 265s plex
mirror.p0 plexoffset 0s
sd name mirror.p0.s1 drive sd1 state up len 4194304s driveoffset 265s plex
mirror.p0 plexoffset 4194304s
sd name mirror.p1.s0 drive sd2 state reviving len 4194304s driveoffset 265s
plex mirror.p1 plexoffset 0s
sd name mirror.p1.s1 drive sd3 state reviving len 4194304s driveoffset 265s
plex mirror.p1 plexoffset 4194304s
To Unsubscribe: send mail to majordomo@FreeBSD.org
with "unsubscribe freebsd-questions" in the body of the message
Want to link to this message? Use this URL: <https://mail-archive.FreeBSD.org/cgi/mid.cgi?4.1.19991003175604.00aa52c0>