Date:      Sun, 29 Jan 2006 15:45:26 +1100
From:      Peter Jeremy <peterjeremy@optushome.com.au>
To:        freebsd-acpi@freebsd.org
Subject:   Discharge rate error on HP nx6125
Message-ID:  <20060129044526.GO2341@turion.vk2pj.dyndns.org>

next in thread | raw e-mail | index | archive | help
When my nx6125 is running from batteries, the discharge rate is reported
as about 30,000mA - this is about an order of magnitude high.  The
capacity warning levels (~5% and 1%) also appear unrealistically low.

turion% acpiconf -i 0
Design capacity:        4725 mAh
Last full capacity:     4725 mAh
Technology:             secondary (rechargeable)
Design voltage:         11100 mV
Capacity (warn):        237 mAh
Capacity (low):         48 mAh
Low/warn granularity:   100 mAh
Warn/full granularity:  100 mAh
Model number:           Primary
Serial number:          14370 2005/09/22
Type:                   LIon
OEM info:               Hewlett-Packard
State:                  discharging 
Remaining capacity:     98%
Remaining time:         1:43
Present rate:           29870 mA
Voltage:                12090 mV

-- 
Peter Jeremy