From owner-freebsd-questions@FreeBSD.ORG Wed Jan 26 21:03:56 2005 Return-Path: Delivered-To: freebsd-questions@freebsd.org Received: from mx1.FreeBSD.org (mx1.freebsd.org [216.136.204.125]) by hub.freebsd.org (Postfix) with ESMTP id 58AD216A4CE for ; Wed, 26 Jan 2005 21:03:56 +0000 (GMT) Received: from smtprelay01.ispgateway.de (smtprelay01.ispgateway.de [80.67.18.13]) by mx1.FreeBSD.org (Postfix) with ESMTP id 131A543D3F for ; Wed, 26 Jan 2005 21:03:55 +0000 (GMT) (envelope-from stefan.pietsch@web.de) Received: (qmail 10428 invoked from network); 26 Jan 2005 21:03:49 -0000 Received: from unknown (HELO web.de) (937371@[212.144.211.114]) (envelope-sender )encrypted SMTP for ; 26 Jan 2005 21:03:49 -0000 Message-ID: <41F805A5.97B7ADBC@web.de> Date: Wed, 26 Jan 2005 22:03:33 +0100 From: Stefan Pietsch X-Mailer: Mozilla 4.8 [en] (Windows NT 5.0; U) MIME-Version: 1.0 To: freebsd-questions@freebsd.org References: <004901c50376$85cc2520$4801a8c0@ws-ew-3.W2KDEMIG> Content-Type: text/plain; charset=us-ascii Content-Transfer-Encoding: 7bit Subject: Re: ISDN connection problems X-BeenThere: freebsd-questions@freebsd.org X-Mailman-Version: 2.1.1 Precedence: list List-Id: User questions List-Unsubscribe: , List-Archive: List-Post: List-Help: List-Subscribe: , X-List-Received-Date: Wed, 26 Jan 2005 21:03:56 -0000 Norbert Koch wrote: > What ppp are you using: kernel, userland or netgraph-based? > Can you post your isdnd.rc, ppp.conf, kernel conf? I login as normal user, enter "ppp" and type "dial ..." to open the internet connection. This is userland ppp I think. ======== ppp.conf ======== default: set cd 180 set log Phase Chat LCP IPCP CCP tun command set device /dev/i4brbch0 /dev/i4brbch1 set dial set hangup set login set proctitle ppp-isdn set speed sync nat enable yes nat log yes arcor: set phone "010700192076" set authname arcor set authkey xxxxx set ifaddr 10.0.0.1/0 10.0.0.2/0 255.255.255.0 0.0.0.0 add default HISADDR set timeout 180 set filter in 0 deny any any tcp dst eq 22 set filter in 1 deny any any udp dst eq 137 set filter in 2 deny any any udp dst eq 138 set filter in 3 deny any any tcp dst eq 139 set filter in 4 deny any any udp dst eq 514 set filter in 5 deny any any tcp dst eq 3128 set filter in 6 permit any any all set filter out 0 deny 192.168.1.0/24 any tcp dst eq 80 set filter out 1 permit any any all allow users stefan ======== isdnd.rc ======== #============================================================================== # SYSTEM section: isdnd global configuration parameters #============================================================================== system # accounting # ---------- acctall = on # generate info for everything acctfile = /var/log/isdnd.acct # name & location of accounting file useacctfile = yes # generate accouting info to file # monitor # ------- monitor-allowed = no # global switch: monitor on/off monitor-port = 451 # default monitor TCP port # Monitor rights are granted due to the most specific host/net spec, i.e. in # the example below host 192.168.1.2 will have the rights specified on that # line, even so it belongs to net 192.168.1.0/24 as well. # # A monitor specification may either be: # # - the name of a local (UNIX-domain) socket; this MUST start with a "/" monitor = "/var/run/isdn-monitor" monitor-access = fullcmd monitor-access = channelstate, logevents monitor-access = callin, callout # # - a dotted-quad host spec monitor = "192.168.1.2" monitor-access = restrictedcmd, channelstate, callin, callout # # - a dotted-quad net spec with "/len" (CIDR-style) netmask spec monitor = "192.168.1.0/24" monitor-access = restrictedcmd, channelstate, callin, callout # # - a resolveable host name #monitor = "rumolt" monitor-access = restrictedcmd, channelstate, callin, callout # # - a resolveable net name with "/len" netmask (s.a.) appended monitor = "up-vision-net/24" monitor-access = restrictedcmd, channelstate, callin, callout # regular expression pattern matching # ----------------------------------- #regexpr = "connected.*XXX" # look for matches in log messages #regprog = connectXXX # execute program when match is found regexpr = " incoming call from" regprog = unknown_incoming # execute program whan match is found # realtime priority section # ------------------------- rtprio = 25 # modify isdnd's process priority #============================================================================== # entry section: IP over ISDN example - i call back the remote end #============================================================================== entry name = I4BPPP # name for reference. This name will # be used in the logfile to identfy # this entry. # the network or telephone device # the data traffic should be routed to: usrdevicename = rbch # ipr, isp, tel, rbch usrdeviceunit = 0 # unit number # the ISDN controller number to be # used for this entry: isdncontroller = 0 # controller to use or -1 to use any isdnchannel = -1 # channel (1/2) to use or 0 or -1 for any # incoming only, outgoing only or both: direction = out # in, out, inout # numbers used to verify a DIAL IN: local-phone-incoming = 994362 # this is my number remote-phone-incoming = 0123456789 # this one can call in # numbers used at DIAL OUT time: local-phone-dialout = 994362 # this is my number remote-phone-dialout = 0123456789 # i call this remote number # in case i have several remote # telephone numbers specified, this # is used to specify which one is # used next on dial fail or retry: remdial-handling = first # first, last or next # what happenes if someone dials in: dialin-reaction = ignore # accept, reject, ignore, answer, callback # normal dialout or do i call back: dialout-type = normal # normal / calledback callbackwait = 1 # no of secs to wait before calling back # type of protocol on the B-channel: # hdlc must be specified for IP (the # ipr and isp drivers), raw must be # specified for telephone answering b1protocol = hdlc # hdlc, raw # shorthold mode and idle time # configuration: ratetype = 0 # ratesfile entry to use unitlength = 90 # unitlength to assume unitlengthsrc = rate # none, rate, cmdl, conf, aocd idletime-incoming = 120 # incoming call idle timeout idletime-outgoing = 120 # outgoing call idle timeout earlyhangup = 5 # time to hangup before an expected # next charging unit will occur # retry and recovery parameters dialretries = 3 # # of dial retries dialrandincr = off # random dial increment time recoverytime = 5 # time to wait between 2 dial tries usedown = off # set i/f down downtries = 5 # retry cycles before set down downtime = 30 # time to be in down before going up #connectprog = "ip-up" # run /etc/isdn/ip-up when an interface # has established its network connection. # example parameters are: # /etc/isdn/ip-up -d isp0 -f up -a 192.110.12.14 #disconnectprog = "ip-down" # like connectprog, but run after the connection # is closed (ISDN layer down). The actual # interface address might not be known # any more. example parameters are: # /etc/isdn/ip-up -d isp0 -f down -a 0.0.0.0 ============= kernel-config ============= machine i386 cpu I586_CPU ident FOOBAR # To statically compile in device wiring instead of /boot/device.hints #hints "GENERIC.hints" # Default places to look for devices. options SCHED_4BSD # 4BSD scheduler options INET # InterNETworking #options INET6 # IPv6 communications protocols options FFS # Berkeley Fast Filesystem options SOFTUPDATES # Enable FFS soft updates support options UFS_ACL # Support for access control lists options UFS_DIRHASH # Improve performance on big directories options MD_ROOT # MD is a potential root device options NFSCLIENT # Network Filesystem Client options NFSSERVER # Network Filesystem Server options NFS_ROOT # NFS usable as /, requires NFSCLIENT options MSDOSFS # MSDOS Filesystem options CD9660 # ISO 9660 Filesystem options PROCFS # Process filesystem (requires PSEUDOFS) options PSEUDOFS # Pseudo-filesystem framework options GEOM_GPT # GUID Partition Tables. options COMPAT_43 # Compatible with BSD 4.3 [KEEP THIS!] options COMPAT_FREEBSD4 # Compatible with FreeBSD4 options SCSI_DELAY=15000 # Delay (in ms) before probing SCSI options KTRACE # ktrace(1) support options SYSVSHM # SYSV-style shared memory options SYSVMSG # SYSV-style message queues options SYSVSEM # SYSV-style semaphores options _KPOSIX_PRIORITY_SCHEDULING # POSIX P1003_1B real-time extensions options KBD_INSTALL_CDEV # install a CDEV entry in /dev options AHC_REG_PRETTY_PRINT # Print register bitfields in debug # output. Adds ~128k to driver. options AHD_REG_PRETTY_PRINT # Print register bitfields in debug # output. Adds ~215k to driver. options ADAPTIVE_GIANT # Giant mutex is adaptive. device apic # I/O APIC # Bus support. Do not remove isa, even if you have no isa slots device isa device eisa device pci # Floppy drives device fdc # ATA and ATAPI devices device ata device atadisk # ATA disk drives device ataraid # ATA RAID drives device atapicd # ATAPI CDROM drives device atapifd # ATAPI floppy drives device atapist # ATAPI tape drives options ATA_STATIC_ID # Static device numbering # SCSI Controllers #device ahb # EISA AHA1742 family #device ahc # AHA2940 and onboard AIC7xxx devices #device ahd # AHA39320/29320 and onboard AIC79xx devices #device amd # AMD 53C974 (Tekram DC-390(T)) #device isp # Qlogic family #device mpt # LSI-Logic MPT-Fusion #device ncr # NCR/Symbios Logic #device sym # NCR/Symbios Logic (newer chipsets + those of `ncr') #device trm # Tekram DC395U/UW/F DC315U adapters #device adv # Advansys SCSI adapters #device adw # Advansys wide SCSI adapters #device aha # Adaptec 154x SCSI adapters #device aic # Adaptec 15[012]x SCSI adapters, AIC-6[23]60. #device bt # Buslogic/Mylex MultiMaster SCSI adapters #device ncv # NCR 53C500 #device nsp # Workbit Ninja SCSI-3 #device stg # TMC 18C30/18C50 # SCSI peripherals #device scbus # SCSI bus (required for SCSI) #device ch # SCSI media changers #device da # Direct Access (disks) #device sa # Sequential Access (tape etc) #device cd # CD #device pass # Passthrough device (direct SCSI access) #device ses # SCSI Environmental Services (and SAF-TE) # RAID controllers interfaced to the SCSI subsystem #device amr # AMI MegaRAID #device asr # DPT SmartRAID V, VI and Adaptec SCSI RAID #device ciss # Compaq Smart RAID 5* #device dpt # DPT Smartcache III, IV - See NOTES for options #device hptmv # Highpoint RocketRAID 182x #device iir # Intel Integrated RAID #device ips # IBM (Adaptec) ServeRAID #device mly # Mylex AcceleRAID/eXtremeRAID #device twa # 3ware 9000 series PATA/SATA RAID # RAID controllers #device aac # Adaptec FSA RAID #device aacp # SCSI passthrough for aac (requires CAM) #device ida # Compaq Smart RAID #device mlx # Mylex DAC960 family #device pst # Promise Supertrak SX6000 #device twe # 3ware ATA RAID # atkbdc0 controls both the keyboard and the PS/2 mouse device atkbdc # AT keyboard controller device atkbd # AT keyboard device psm # PS/2 mouse device vga # VGA video card driver device splash # Splash screen and screen saver support # syscons is the default console driver, resembling an SCO console device sc # Enable this for the pcvt (VT220 compatible) console driver #device vt #options XSERVER # support for X server on a vt console #options FAT_CURSOR # start with block cursor device agp # support several AGP chipsets # Floating point support - do not disable. device npx # Power management support (see NOTES for more options) #device apm # Add suspend/resume support for the i8254. device pmtimer # PCCARD (PCMCIA) support # PCMCIA and cardbus bridge support #device cbb # cardbus (yenta) bridge #device pccard # PC Card (16-bit) bus #device cardbus # CardBus (32-bit) bus # Serial (COM) ports device sio # 8250, 16[45]50 based serial ports # Parallel port device ppc device ppbus # Parallel port bus (required) device lpt # Printer device plip # TCP/IP over parallel device ppi # Parallel port interface device #device vpo # Requires scbus and da # If you've got a "dumb" serial or parallel PCI card that is # supported by the puc(4) glue driver, uncomment the following # line to enable it (connects to the sio and/or ppc drivers): #device puc # PCI Ethernet NICs. device de # DEC/Intel DC21x4x (``Tulip'') device em # Intel PRO/1000 adapter Gigabit Ethernet Card device ixgb # Intel PRO/10GbE Ethernet Card device txp # 3Com 3cR990 (``Typhoon'') device vx # 3Com 3c590, 3c595 (``Vortex'') # PCI Ethernet NICs that use the common MII bus controller code. # NOTE: Be sure to keep the 'device miibus' line in order to use these NICs! device miibus # MII bus support device bfe # Broadcom BCM440x 10/100 Ethernet device bge # Broadcom BCM570xx Gigabit Ethernet device dc # DEC/Intel 21143 and various workalikes device fxp # Intel EtherExpress PRO/100B (82557, 82558) device lge # Level 1 LXT1001 gigabit ethernet device nge # NatSemi DP83820 gigabit ethernet device pcn # AMD Am79C97x PCI 10/100 (precedence over 'lnc') device re # RealTek 8139C+/8169/8169S/8110S device rl # RealTek 8129/8139 device sf # Adaptec AIC-6915 (``Starfire'') device sis # Silicon Integrated Systems SiS 900/SiS 7016 device sk # SysKonnect SK-984x & SK-982x gigabit Ethernet device ste # Sundance ST201 (D-Link DFE-550TX) device ti # Alteon Networks Tigon I/II gigabit Ethernet device tl # Texas Instruments ThunderLAN device tx # SMC EtherPower II (83c170 ``EPIC'') device vge # VIA VT612x gigabit ethernet device vr # VIA Rhine, Rhine II device wb # Winbond W89C840F device xl # 3Com 3c90x (``Boomerang'', ``Cyclone'') # ISA Ethernet NICs. pccard NICs included. device cs # Crystal Semiconductor CS89x0 NIC # 'device ed' requires 'device miibus' device ed # NE[12]000, SMC Ultra, 3c503, DS8390 cards device ex # Intel EtherExpress Pro/10 and Pro/10+ device ep # Etherlink III based cards device fe # Fujitsu MB8696x based cards device ie # EtherExpress 8/16, 3C507, StarLAN 10 etc. device lnc # NE2100, NE32-VL Lance Ethernet cards device sn # SMC's 9000 series of Ethernet chips device xe # Xircom pccard Ethernet # ISA devices that use the old ISA shims #device le # Wireless NIC cards #device wlan # 802.11 support #device an # Aironet 4500/4800 802.11 wireless NICs. #device awi # BayStack 660 and others #device wi # WaveLAN/Intersil/Symbol 802.11 wireless NICs. #device wl # Older non 802.11 Wavelan wireless NIC. # Pseudo devices. device loop # Network loopback device mem # Memory and kernel memory devices device io # I/O device device random # Entropy device device ether # Ethernet support device sl # Kernel SLIP device ppp # Kernel PPP device tun # Packet tunnel. device pty # Pseudo-ttys (telnet etc) device md # Memory "disks" device gif # IPv6 and IPv4 tunneling device faith # IPv6-to-IPv4 relaying (translation) # The `bpf' device enables the Berkeley Packet Filter. # Be aware of the administrative consequences of enabling this! device bpf # Berkeley packet filter # USB support #device uhci # UHCI PCI->USB interface #device ohci # OHCI PCI->USB interface #device usb # USB Bus (required) #device udbp # USB Double Bulk Pipe devices #device ugen # Generic #device uhid # "Human Interface Devices" #device ukbd # Keyboard #device ulpt # Printer #device umass # Disks/Mass storage - Requires scbus and da #device ums # Mouse #device urio # Diamond Rio 500 MP3 player #device uscanner # Scanners # USB Ethernet, requires mii #device aue # ADMtek USB Ethernet #device axe # ASIX Electronics USB Ethernet #device cue # CATC USB Ethernet #device kue # Kawasaki LSI USB Ethernet #device rue # RealTek RTL8150 USB Ethernet # FireWire support #device firewire # FireWire bus code #device sbp # SCSI over FireWire (Requires scbus and da) #device fwe # Ethernet over FireWire (non-standard!) # ISDN Section I4B device ifpi device "i4bq921" device "i4bq931" device "i4b" device "i4btrc" 4 device "i4bctl" device "i4brbch" 4 device "i4btel" 4 device "i4bipr" 4 device "i4bisppp" 4 options IPR_VJ =====