Hi!

As said in the subject, i try to install an INSITE Floptical drive.

Ang all i get is this in my dmesg:

Waiting 3 seconds for SCSI devices to settle

sym0: <895> port 0xe800-0xe8ff mem 0xeb002000-0xeb002fff,0xeb001000-0xeb0010ff irq 9 at device 11.0 on pci0
sym0: Tekram NVRAM, ID 7, Fast-40, SE, parity checking
...
(noperiph:sym0:0:-1:-1): SCSI BUS mode change from SE to SE.
(probe2:sym0:0:2:0): phase change 6-2 6@1f1de98c resid=5.
sym0: unexpected disconnect
sym0: unexpected disconnect
sym0: unexpected disconnect
sym0: unexpected disconnect
sym0: unexpected disconnect
sym0: unexpected disconnect
sym0: unexpected disconnect
sym0: unexpected disconnect
sym0: unexpected disconnect
sym0: unexpected disconnect
sym0: unexpected disconnect
sym0: unexpected disconnect
sym0: unexpected disconnect
sym0: unexpected disconnect
sym0: unexpected disconnect
sym0: unexpected disconnect
sym0: unexpected disconnect
sym0: unexpected disconnect
sym0: unexpected disconnect
sym0: unexpected disconnect
sym0: unexpected disconnect
sym0: unexpected disconnect
sym0: unexpected disconnect
sym0: unexpected disconnect
sym0: unexpected disconnect
sym0: unexpected disconnect
sym0: unexpected disconnect
sym0: unexpected disconnect
sym0: unexpected disconnect
sym0: unexpected disconnect
sym0: unexpected disconnect
sym0: unexpected disconnect
sym0: unexpected disconnect
sym0: unexpected disconnect
sym0: unexpected disconnect
sa0 at sym0 bus 0 target 5 lun 0
sa0: <SONY SDT-10000 0110> Removable Sequential Access SCSI-2 device 
sa0: 40.000MB/s transfers (20.000MHz, offset 15, 16bit)
(da1:sym0:0:2:0): phase change 6-2 6@1f1fd78c resid=5.
Mounting root from ufs:/dev/ad0s2a
da0 at sym0 bus 0 target 1 lun 0
da0: <SEAGATE ST318405LW 0105> Fixed Direct Access SCSI-3 device 
da0: 40.000MB/s transfers (20.000MHz, offset 31, 16bit), Tagged Queueing Enabled
da0: 17501MB (35843670 512 byte sectors: 255H 63S/T 2231C)
(da1:sym0:0:2:0): phase change 6-2 6@1f1fd78c resid=5.
(da1:sym0:0:2:0): phase change 6-2 6@1f1fd78c resid=5.
(da1:sym0:0:2:0): phase change 6-2 6@1f1fd78c resid=5.
(da1:sym0:0:2:0): phase change 6-2 6@1f1fd78c resid=5.
da1 at sym0 bus 0 target 2 lun 0
da1: <INSITE I325VM        *F 0381> Removable Direct Access SCSI-CCS device 
da1: 3.300MB/s transfers
da1: Attempt to query device size failed: MEDIUM ERROR, Track following error


An advice is welcome.

Thanks in advance.