Date: Thu, 01 Sep 2005 10:39:36 -0600 From: Scott Long <scottl@samsco.org> To: "Antonio Nati - Inter@zioni" <a.nati@interazioni.it> Cc: freebsd-scsi@freebsd.org Subject: Re: camcontrol and IDAD0 Message-ID: <43172EC8.1010205@samsco.org> In-Reply-To: <6.2.3.4.0.20050901172618.0532ecb0@pop.ufficiopostale.it> References: <6.2.3.4.0.20050901172618.0532ecb0@pop.ufficiopostale.it>
next in thread | previous in thread | raw e-mail | index | archive | help
The IDA devices are not under the CAM subsystem, so camcontrol will have no effect on them. I assume that you are looking for a way to monitor and manage the controller and arrays? That requires a custom application that knows how to speak to the controller firmware. Even if IDA were under CAM, camcontrol would not be able to do this. Scott Antonio Nati - Inter@zioni wrote: > > How can I handle Compaq Smart Raid disks using camcontrol? > > I've looked a lot around, and found sometimes the same question, but no > answers: > > I've an internal Smart Raid card (on a DL360) handling a mirrored set of > disks. > > Boot says: > Aug 5 21:23:13 ia-srv01 kernel: idad0: <Compaq Logical Drive> on ida0 > Aug 5 21:23:13 ia-srv01 kernel: idad0: 17359MB (35553120 sectors), > blocksize=512 > > RAID is working properly, but I have no way (apparently) to check it > within FreeBSD. > > Command "camcontrol devlist -v" returns > > scbus-1 on xpt0 bus 0: > < > at scbus-1 target -1 lun -1 (xpt0) > > atacontrol does not says anything about this disk. > > What can I do? Is there any other resource/command available in order to > solve this problem? > > Thanks, > > Tonino > > _______________________________________________ > freebsd-scsi@freebsd.org mailing list > http://lists.freebsd.org/mailman/listinfo/freebsd-scsi > To unsubscribe, send any mail to "freebsd-scsi-unsubscribe@freebsd.org"
Want to link to this message? Use this URL: <https://mail-archive.FreeBSD.org/cgi/mid.cgi?43172EC8.1010205>