Skip site navigation (1)Skip section navigation (2)
Date:      Wed, 01 Feb 2012 16:56:23 +0100
From:      Willem Jan Withagen <wjw@digiware.nl>
To:        Jeremy Chadwick <freebsd@jdc.parodius.com>,  "stable@freebsd.org" <stable@freebsd.org>
Subject:   Re: Troube with SSD
Message-ID:  <4F2960A7.8040705@digiware.nl>
In-Reply-To: <20120201143942.GA96012@icarus.home.lan>
References:  <4F2940C1.10901@digiware.nl> <20120201143942.GA96012@icarus.home.lan>

next in thread | previous in thread | raw e-mail | index | archive | help
On 2012-02-01 15:39, Jeremy Chadwick wrote:
> On Wed, Feb 01, 2012 at 02:40:17PM +0100, Willem Jan Withagen wrote:
>> The device is a Corsair 60Gb Force GT. And thusfar I have not found any
>> suggestions that that serie of devices is prone to doing this.
> 
> Can you please provide the following output when that SSD is attached
> to the system?  You will need to install ports/sysutils/smartmontools
> for this (please make sure it's version 5.42 or newer).
> 
> * smartctl -a /dev/whatever
> * smartctl -l devstat /dev/whatever
> * smartctl -l sataphy /dev/whatever
> * smartctl -l ssd /dev/whatever

Eh, the last 3 look like they are not supported on the 3ware controller:
ATA_READ_LOG_EXT (addr=0x00:0x00, page=0, n=1) failed: 48-bit ATA
commands not supported
Read GP Log Directory failed.

So I'll have to put it back in my real fileserver.

The output of the first one command, but it contains some real weird
values.....??

--WjW

=== START OF INFORMATION SECTION ===
Device Model:     Corsair Force GT
Serial Number:    11296503000005870891
LU WWN Device Id: 0 000000 000000000
Firmware Version: 1.2
User Capacity:    60,022,480,896 bytes [60.0 GB]
Sector Size:      512 bytes logical/physical
Device is:        Not in smartctl database [for details use: -P showall]
ATA Version is:   8
ATA Standard is:  ACS-2 revision 3
Local Time is:    Wed Feb  1 16:52:42 2012 CET
SMART support is: Available - device has SMART capability.
SMART support is: Enabled

=== START OF READ SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED

General SMART Values:
Offline data collection status:  (0x00) Offline data collection activity
                                        was never started.
                                        Auto Offline Data Collection:
Disabled.
Self-test execution status:      (   0) The previous self-test routine
completed
                                        without error or no self-test
has ever
                                        been run.
Total time to complete Offline
data collection:                (    0) seconds.
Offline data collection
capabilities:                    (0x7f) SMART execute Offline immediate.
                                        Auto Offline data collection
on/off support.
                                        Abort Offline collection upon new
                                        command.
                                        Offline surface scan supported.
                                        Self-test supported.
                                        Conveyance Self-test supported.
                                        Selective Self-test supported.
SMART capabilities:            (0x0003) Saves SMART data before entering
                                        power-saving mode.
                                        Supports SMART auto save timer.
Error logging capability:        (0x01) Error logging supported.
                                        General Purpose Logging supported.
Short self-test routine
recommended polling time:        (   1) minutes.
Extended self-test routine
recommended polling time:        (  48) minutes.
Conveyance self-test routine
recommended polling time:        (   2) minutes.
SCT capabilities:              (0x0021) SCT Status supported.
                                        SCT Data Table supported.

SMART Attributes Data Structure revision number: 10
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME          FLAG     VALUE WORST THRESH TYPE
UPDATED  WHEN_FAILED RAW_VALUE
  1 Raw_Read_Error_Rate     0x000f   082   082   050    Pre-fail  Always
      -       897651373777
  5 Reallocated_Sector_Ct   0x0033   100   100   003    Pre-fail  Always
      -       0
  9 Power_On_Hours          0x0032   100   100   000    Old_age   Always
      -       121242631799621
 12 Power_Cycle_Count       0x0032   100   100   000    Old_age   Always
      -       31
171 Unknown_Attribute       0x0032   000   000   000    Old_age   Always
      -       0
172 Unknown_Attribute       0x0032   000   000   000    Old_age   Always
      -       0
174 Unknown_Attribute       0x0030   000   000   000    Old_age
Offline      -       19
177 Wear_Leveling_Count     0x0000   000   000   000    Old_age
Offline      -       0
181 Program_Fail_Cnt_Total  0x0032   000   000   000    Old_age   Always
      -       0
182 Erase_Fail_Count_Total  0x0032   000   000   000    Old_age   Always
      -       0
187 Reported_Uncorrect      0x0032   100   100   000    Old_age   Always
      -       0
194 Temperature_Celsius     0x0022   026   035   000    Old_age   Always
      -       26 (Min/Max 21/35)
195 Hardware_ECC_Recovered  0x001c   120   120   000    Old_age
Offline      -       897651373777
196 Reallocated_Event_Count 0x0033   100   100   003    Pre-fail  Always
      -       0
201 Soft_Read_Error_Rate    0x001c   120   120   000    Old_age
Offline      -       897651373777
204 Soft_ECC_Correction     0x001c   120   120   000    Old_age
Offline      -       897651373777
230 Head_Amplitude          0x0013   100   100   000    Pre-fail  Always
      -       429496729700
231 Temperature_Celsius     0x0013   100   100   010    Pre-fail  Always
      -       0
233 Media_Wearout_Indicator 0x0000   000   000   000    Old_age
Offline      -       1260
234 Unknown_Attribute       0x0032   000   000   000    Old_age   Always
      -       1925
241 Total_LBAs_Written      0x0032   000   000   000    Old_age   Always
      -       1925
242 Total_LBAs_Read         0x0032   000   000   000    Old_age   Always
      -       1032

SMART Error Log not supported
SMART Self-test Log not supported
SMART Selective self-test log data structure revision number 1
 SPAN  MIN_LBA  MAX_LBA  CURRENT_TEST_STATUS
    1        0        0  Not_testing
    2        0        0  Not_testing
    3        0        0  Not_testing
    4        0        0  Not_testing
    5        0        0  Not_testing
Selective self-test flags (0x0):
  After scanning selected spans, do NOT read-scan remainder of disk.
If Selective self-test is pending on power-up, resume after 0 minute delay.




Want to link to this message? Use this URL: <https://mail-archive.FreeBSD.org/cgi/mid.cgi?4F2960A7.8040705>