Skip site navigation (1)Skip section navigation (2)
Date:      Thu, 6 May 2010 14:17:13 -0700
From:      Ulf Zimmermann <ulf@Alameda.net>
To:        Sean Bruno <seanbru@yahoo-inc.com>
Cc:        "freebsd-scsi@freebsd.org" <freebsd-scsi@freebsd.org>, "Erich Jenkins, Fuujin Group Ltd" <erich@fuujingroup.com>
Subject:   Re: kern/146287: [ciss] ciss(4) cannot see more than one SmartArray controller
Message-ID:  <20100506211713.GT30353@evil.alameda.net>
In-Reply-To: <1273172053.2465.8.camel@localhost.localdomain>
References:  <1273087076.2487.4.camel@localhost.localdomain> <20100505203116.GP30353@evil.alameda.net> <20100505204652.GQ30353@evil.alameda.net> <1273092737.2487.5.camel@localhost.localdomain> <20100506014748.GR30353@evil.alameda.net> <1273165130.2465.4.camel@localhost.localdomain> <20100506174113.GS30353@evil.alameda.net> <1273169980.2465.6.camel@localhost.localdomain> <4BE318A8.6050108@fuujingroup.com> <1273172053.2465.8.camel@localhost.localdomain>

next in thread | previous in thread | raw e-mail | index | archive | help
On Thu, May 06, 2010 at 11:54:13AM -0700, Sean Bruno wrote:
> 
> > > 
> > 
> > Not sure if this helps or not, but we've got about 20 of these machines, 
> > as well as the DL580 version in production. I've seen this very same 
> > issue on the ML series machines also. If I remember correctly, there 
> > were two different PCI bridges used in the same production models, one 
> > was from IBM and the other was a ServerWorks (Broadcom) chipset. One 
> > didn't show up at all (not even when probed) and the other one was 
> > displayed. Can't remember which was which, but I know it had to do with 
> > hot-swap PCI subsystem, and I suspect this is what you're experiencing. 
> > We had a similar experience with MyriCom 10GE cards in an ML570 with a 
> > hot-swap PCI option. The card wouldn't show up in slot closest to the 
> > Mem card (can't remember if the DL380's have a riser card for ram or if 
> > this is onboard), but it worked in the next slot over.
> > 
> > 
> > Erich M. Jenkins
> > Fuujin Group Limited
> > 
> > 
> > "You should never, never doubt what no one is sure about."
> > -- Gene Wilder
> > 
> 
> It does help a bit.
> 
> Basically, we need an AML dump of the ACPI information from one of the
> machines that has an IBM based bridge chip.
> 
> acpidump -dt
> 
> sean
> 
> 

I wonder what bridge chip is used in the DL380 g3, as far I know the ones
we have should be hotswap PCI-X. On the DL380 g4 the standard cage was not
hotswap and I think we don't have any of those.

Looking at the product specs of a DL380 g3, it shows different
bus for slot 1 (bottom at 64-bit/133Mhz PCI-X) against slot 2+3 (middle
and top slot at 64-bit/100Mhz PCI-X).

I got one DL380 g3 myself, which isn't running much right now, so I will
check out what PCI devices I can see.

-- 
Regards, Ulf.

---------------------------------------------------------------------
Ulf Zimmermann, 1525 Pacific Ave., Alameda, CA-94501, #: 510-865-0204
You can find my resume at: http://www.Alameda.net/~ulf/resume.html



Want to link to this message? Use this URL: <https://mail-archive.FreeBSD.org/cgi/mid.cgi?20100506211713.GT30353>