Date: Mon, 05 Mar 2012 18:42:21 +0100 From: Davide D'Amico <davide.damico@contactlab.com> To: kpneal@pobox.com Cc: freebsd-fs@freebsd.org Subject: Re: FreeBSD 8.2-p5 and Perc6/i Message-ID: <4F54FAFD.9070101@contactlab.com> In-Reply-To: <20120305143609.GA76430@neutralgood.org> References: <fd31ae8eb27df3899a274052585778fe@sys.tomatointeractive.it> <20120305143609.GA76430@neutralgood.org>
next in thread | previous in thread | raw e-mail | index | archive | help
Il 05/03/12 15:36, kpneal@pobox.com ha scritto: > On Sat, Mar 03, 2012 at 10:00:21AM +0100, Davide D'Amico wrote: >> Hi all, >> I've a couple of dell r410 servers (smtp1 and smtp2) in production with >> the same hw config: > >> Mar 2 22:29:59.056 smtp2 mfi0: COMMAND 0xffffff80009aa7f8 TIMEOUT >> AFTER 1784 SECONDS > I've got an R610 running 8.2-RELEASE with the same card. I was seeing the > same errors until I changed BIOS settings. The settings need to be for > "high performance" and all the fancy power saving settings like the C1E > states need to be disabled. > > I'm sorry I can't be more specific. The machine in question is running in > a datacenter so I can't check. Very thanks, after having turned off "Turbo mode", "C1E", "C-State" in Bios -> Processor everything went fine. Thanks, d.
Want to link to this message? Use this URL: <https://mail-archive.FreeBSD.org/cgi/mid.cgi?4F54FAFD.9070101>