Date: Mon, 14 May 2007 18:08:38 -1000 From: NetOpsCenter <noc@hdk5.net> To: Aftab Jahan Subedar <jahan@bol-online.com>, freebsd-questions@freebsd.org Subject: Re: Auto shutdown/restart software for FreeBSD? Message-ID: <46493246.2070802@hdk5.net> In-Reply-To: <da9e9eb60705131717n716900dbgbba0e4a141cab075@mail.gmail.com> References: <23042ea705a53aea5d36bb86a06d3b4c@prodigy.net> <46466861.8000706@hdk5.net> <da9e9eb60705131717n716900dbgbba0e4a141cab075@mail.gmail.com>
next in thread | previous in thread | raw e-mail | index | archive | help
Aftab Jahan Subedar wrote: > Would it recharge the battery fully after discharge? I dont think so. > So you got to recharge the external battery EXTERNALLY after power > failure. > Aloha Aftab, This was the first thing I tested. I unplugged the unit and let it run on battery all day while I was in town. Then I plugged in the UPS and its internal charger did its thing until the next day and I tested the current with a big amp meter I got from an auto sourse store and it was fully charged in less than 24 hrs. It was not fully discharged by the way even when the battery ran the 2 servers for the 9 hours. Al > Hey welcome to visit Dhaka. > > Regards- > > Aftab Jahan Subedar > CEO/Software Engineer > Subedar Technologies Ltd > Soubedar Baag Bibir Bagicha #1 > North Jatra Bari > Dhaka 1204 > Bangladesh > +880152635208 > -http://www.DhakaStockExchangeGame.com > Spyware detector -http://www.google.com/search?q=kayoty > > > On 5/13/07, NetOpsCenter <noc@hdk5.net> wrote: > >> >> jekillen wrote: >> >> > Hello again; >> > Is there software for ups auto shutdown and restart for use with a ups >> > system that has the capacity; I.E. a serial connection and references >> > in the manual to software (for Windows mostly) download? Currently >> > I have a Vesta Pro 600 unit. I had one made by Minuteman that crapped >> > out on me last night. It had been doing ok and was a replacement >> for one >> > made by Tripp Lite, which also failed permanently. I am running one >> desk >> > top FreeBSD system, headless but with high speed SCSI drives in >> addition >> > to the boot drive. I am away during the week for at least 8 - 9 hours >> > during >> > the week and cant be there if the power goes down to shut the system >> > down before the ups exhausts its battery. >> > Thanks in advance for any suggestions. >> > Jeff K. >> > >> > _______________________________________________ >> > freebsd-questions@freebsd.org mailing list >> > http://lists.freebsd.org/mailman/listinfo/freebsd-questions >> > To unsubscribe, send any mail to >> > "freebsd-questions-unsubscribe@freebsd.org" >> > >> Aloha Jekillen, >> >> >> I had a similar problem here in Hawaii with our 2 noc servers. I >> replaced the small UPS battery with a 100 amp stationery battery out >> side the box. It now will run for about 10 hours if we have a power >> outage for that long. >> >> >> >> ~Al Plant - Honolulu, Hawaii - Phone: 808-284-2740 >> + http://hawaiidakine.com + http://freebsdinfo.org + noc@hdk5.net + >> + http://internetohana.org - Supporting - FreeBSD 6.* - 7.* + >> "All that's really worth doing is what we do for others."- Lewis Carrol >> >> >> _______________________________________________ >> freebsd-questions@freebsd.org mailing list >> http://lists.freebsd.org/mailman/listinfo/freebsd-questions >> To unsubscribe, send any mail to " >> freebsd-questions-unsubscribe@freebsd.org" >> > > > -- ~Al Plant - Honolulu, Hawaii - Phone: 808-284-2740 + http://hawaiidakine.com + http://freebsdinfo.org + noc@hdk5.net + + http://internetohana.org - Supporting - FreeBSD 6.* - 7.* + "All that's really worth doing is what we do for others."- Lewis Carrol
Want to link to this message? Use this URL: <https://mail-archive.FreeBSD.org/cgi/mid.cgi?46493246.2070802>