Date: Sat, 8 Sep 2001 18:50:44 -0700 (PDT) From: Tom Samplonius <tom@sdf.com> To: Michael Burns <michael@fasturl.net> Cc: freebsd-scsi@freebsd.org Subject: Re: RAID 5 controller replacement (DPT/Adaptec SmartRAID IV) Message-ID: <Pine.BSF.4.05.10109081849500.229-100000@misery.sdf.com> In-Reply-To: <20010909003733.A60723@fasturl.net>
next in thread | previous in thread | raw e-mail | index | archive | help
On Sun, 9 Sep 2001, Michael Burns wrote: > ON Sat, Sep 08, 2001 at 04:22:36PM -0700, Tom Samplonius wrote: > > > > I've had a DPT SmartRAID IV die before. I popped in a new controllor, > > hooked up the drive array and turned it on. Everything just worked. The > > DPT controllers store the config in NVRAM and on disk. If there is no > > config in NVRAM, and it pull it off the disks. > > Do you know whether the array was RAID 5? Yes, it was RAID 5. I don't really see that the DPT treats logical disks any differently no matter what the RAID level. The config goes on disk regardless. > > -- > Michael Burns > Systems Administrator > Vener Net Inc. > michael@fasturl.net > > Tom To Unsubscribe: send mail to majordomo@FreeBSD.org with "unsubscribe freebsd-scsi" in the body of the message
Want to link to this message? Use this URL: <https://mail-archive.FreeBSD.org/cgi/mid.cgi?Pine.BSF.4.05.10109081849500.229-100000>