From owner-freebsd-scsi@FreeBSD.ORG Fri Dec 28 11:12:47 2012 Return-Path: Delivered-To: freebsd-scsi@FreeBSD.org Received: from mx1.freebsd.org (mx1.freebsd.org [69.147.83.52]) by hub.freebsd.org (Postfix) with ESMTP id 40A62C05 for ; Fri, 28 Dec 2012 11:12:47 +0000 (UTC) (envelope-from dppascual@gmail.com) Received: from mail-ie0-f173.google.com (mail-ie0-f173.google.com [209.85.223.173]) by mx1.freebsd.org (Postfix) with ESMTP id 04F298FC08 for ; Fri, 28 Dec 2012 11:12:46 +0000 (UTC) Received: by mail-ie0-f173.google.com with SMTP id e13so12609619iej.4 for ; Fri, 28 Dec 2012 03:12:46 -0800 (PST) DKIM-Signature: v=1; a=rsa-sha256; c=relaxed/relaxed; d=gmail.com; s=20120113; h=mime-version:date:message-id:subject:from:to:content-type; bh=+jsI0JSmnbstoFq8vDBu7c5gBWX1hhH6tTjTZ8tPMfs=; b=vzOFfN46EhEcuwimvBSUzFBe6BA/aopmV9cBVf+hFisXm8bSznq6Q/1NVCt4yYA3nb J4eUGDUGQ0Io/xWXRYYR9z0Xds9pivxP7ny8ukr+j/hZHTsh9ECw5cKM1vPGaBgqz0Pm 2c6GFyFXBUmptRvqBVoa4+UkdWMYknhn4jD98x4bGbFV2nijwomzzwqwsjWGSt/CUhL6 gdv+5tMxndZk3BwfX17CWm6ntYPuyaBYbdb7d+uVkDGFc7f3zVjyRuf1jwg1GxC6yGVk 1vkcJpz3V+CCRqFy62FWlaba/FbDAw+XKfYBNpQdM+pwkU6Pq/YD2ytBcWrFeZyFD5Oy pdcQ== MIME-Version: 1.0 Received: by 10.50.178.67 with SMTP id cw3mr29642636igc.53.1356693166094; Fri, 28 Dec 2012 03:12:46 -0800 (PST) Received: by 10.50.153.168 with HTTP; Fri, 28 Dec 2012 03:12:46 -0800 (PST) Date: Fri, 28 Dec 2012 12:12:46 +0100 Message-ID: Subject: driver mps - CAM status: SCSI Status Error From: Dani To: freebsd-scsi@FreeBSD.org Content-Type: text/plain; charset=ISO-8859-1 X-Content-Filtered-By: Mailman/MimeDel 2.1.14 X-BeenThere: freebsd-scsi@freebsd.org X-Mailman-Version: 2.1.14 Precedence: list List-Id: SCSI subsystem List-Unsubscribe: , List-Archive: List-Post: List-Help: List-Subscribe: , X-List-Received-Date: Fri, 28 Dec 2012 11:12:47 -0000 Hi all, I have installed FreeBSD 9.1-RC3 on Dell PowerEdge r720. This server is connected to the storage array Dell PowerVault MD3200 using SAS cables. When we turn on the server (Dell PowerEdge r720), FreeBSD detects the SAS disks (Dell PowerVault MD3200), however it shows the following errors in the boot time and when we create a ZFS pool with these disks. (da19:mps0:0:3:19): CAM status: SCSI Status Error (da19:mps0:0:3:19): SCSI status: Check Condition (da19:mps0:0:3:19): SCSI sense: ILLEGAL REQUEST asc:94,1 (Vendor Specific ASC) (da19:mps0:0:3:19): Error 22, Unretryable error (da19:mps0:0:3:19): READ(10). CDB: 28 0 0 0 0 2 0 0 1 0 (da19:mps0:0:3:19): CAM status: SCSI Status Error (da19:mps0:0:3:19): SCSI status: Check Condition (da19:mps0:0:3:19): SCSI sense: ILLEGAL REQUEST asc:94,1 (Vendor Specific ASC) (da19:mps0:0:3:19): Error 22, Unretryable error (da19:mps0:0:3:19): READ(10). CDB: 28 0 0 0 0 10 0 0 1 0 (da19:mps0:0:3:19): CAM status: SCSI Status Error (da19:mps0:0:3:19): SCSI status: Check Condition (da19:mps0:0:3:19): SCSI sense: ILLEGAL REQUEST asc:94,1 (Vendor Specific ASC) (da19:mps0:0:3:19): Error 22, Unretryable error (da19:mps0:0:3:19): READ(10). CDB: 28 0 0 0 0 80 0 0 1 0 (da19:mps0:0:3:19): CAM status: SCSI Status Error (da19:mps0:0:3:19): SCSI status: Check Condition (da19:mps0:0:3:19): SCSI sense: ILLEGAL REQUEST asc:94,1 (Vendor Specific ASC) (da19:mps0:0:3:19): Error 22, Unretryable error (da19:mps0:0:3:19): READ(10). CDB: 28 0 0 0 0 0 0 0 1 0 (da19:mps0:0:3:19): CAM status: SCSI Status Error (da19:mps0:0:3:19): SCSI status: Check Condition (da19:mps0:0:3:19): SCSI sense: ILLEGAL REQUEST asc:94,1 (Vendor Specific ASC) (da19:mps0:0:3:19): Error 22, Unretryable error cannot create 'storage': one or more devices is currently unavailable Thanks. Regards.