Date: Thu, 18 Jul 1996 01:30:04 +0800 (GMT+0800) From: "Humprey C. Sy" <09210679@mail4.dlsu.edu.ph> To: questions@freebsd.org Subject: Questions on signals Message-ID: <Pine.LNX.3.91.960718012332.26260A-100000@mail4.dlsu.edu.ph>
next in thread | raw e-mail | index | archive | help
What will be the behavior of a process if it receives a signal twice simultaneously (i.e. it receives two SIGALRM signals simultaneously)? I've read the man page, and it mentioned that in the case that it receives another SIGALRM when inside a SIGALRM signal handler routine, this second SIGALRM will be masked, and will be unmasked once the routine finishes its execution. I've tried to see if this is the case, but it doesn't seem to work. Am I getting this right? I would appreciate any help on this. Thank you very much! Humprey Sy De La Salle University Manila, Philippines