I'm runing 4.5-release.  From my dmesg:

ahc0: <Adaptec 19160B Ultra160 SCSI adapter> port 0x9000-0x90ff mem 0xdf800000-0
xdf800fff irq 11 at device 12.0 on pci0
aic7892: Ultra160 Wide Channel A, SCSI Id=7, 32/255 SCBs

da0 at ahc0 bus 0 target 0 lun 0
da0: <IBM DGHS18Y  CLAR18( 3C3C> Fixed Direct Access SCSI-3 device 
da0: 40.000MB/s transfers (20.000MHz, offset 15, 16bit), Tagged Queueing Enabled
da0: 17501MB (35843670 512 byte sectors: 255H 63S/T 2231C)
da1 at ahc0 bus 0 target 1 lun 0
da1: <FUJITSU MAF3364L SUN36G 1213> Fixed Direct Access SCSI-2 device 
da1: 40.000MB/s transfers (20.000MHz, offset 63, 16bit), Tagged Queueing Enabled
da1: 34732MB (71132959 512 byte sectors: 255H 63S/T 4427C)


Notice that I'm only getting 40MB/s transfers.  The BIOS detects them
at 40MB/s, even though I have the max transfer set to 160.  It does
this with one or two drives on the bus.  They are SCA drives in
adapters (any chance it is a jumper on the adapter?).

How do I get 160MB/s on these drives?  As near as I can tell from the
spec sheets, they both should support 160MB/s.

Warner