Skip site navigation (1)Skip section navigation (2)
Date:      Wed, 25 Nov 1998 18:06:56 -0500
From:      Randall Hopper <aa8vb@pagesz.net>
To:        current@FreeBSD.ORG
Subject:   Re: SANE & 3.0-RELEASE? - YES!
Message-ID:  <19981125180656.A2751@pagesz.net>
In-Reply-To: <19981122201349.B19160@pagesz.net>; from Randall Hopper on Sun, Nov 22, 1998 at 08:13:49PM -0500
References:  <19981122101554.A8319@pagesz.net> <199811222319.QAA00516@panzer.plutotech.com> <19981122201349.B19160@pagesz.net>

next in thread | previous in thread | raw e-mail | index | archive | help
     Thanks to a SANE patch for CAM from Corey Kempf <ckempf@enigami.com>,
and advice from Corey and Amancio Hasty <hasty@rah.star-gate.com>, SANE is
now up-n-running ELF/CAM on my box controlling my SCSI Microtek E6 Scanner
(under GIMP no less, without a GIMP recompile).  Thaks for the help guys!

     For the archives, here's what was needed beyond applying Cory's patch,
and building/installing SANE:

1) First, for convenience, wire the scanner down to a specific CAM
   pass-through device.  Example kernel config line:

      device pass0 at scbus0 target 6 unit 0  # CAM passthrough = Scanner

2) Make sure the relevent CAM passthrough and TLI devices exist.  In my
   case they did (/dev/pass0 and /dev/xpt0, respectively).

3) Open up permissions to those devices so the relevent scanner
   users/groups can access them.  E.g.:

   crw-rw----  1 root  scanner   31,   0 Nov 24 18:32 /dev/pass0
   crw-rw----  1 root  scanner  104,   0 Nov 17 17:32 /dev/xpt0

   works for me since the scanner grp is all that need xpt0 access.

4) Insert the appropriate /dev/pass? device name into your scanner's
   SANE config file in /usr/local/etc/sane.d/ (mine: microtek.conf).  E.g.:

     #Uncomment following line to disable "clever precalibration" routines...
     #noprecal
     scsi * * Scanner
     /dev/pass0

   NOTE:  Unlike pre-CAM SANEs, you cannot create a symlink or hardlink
   (e.g. /dev/scanner) pointing to the real pass-through device, and then
   add the symlink path to this file.  The config file has to literally
   contain the /dev/pass? device name.

5) Then fire up the scanner, rescan the bus (camcontrol rescan 0),
   make sure the scanner is there (camcontrol devlist), and scan away!

Randall

To Unsubscribe: send mail to majordomo@FreeBSD.org
with "unsubscribe freebsd-current" in the body of the message



Want to link to this message? Use this URL: <https://mail-archive.FreeBSD.org/cgi/mid.cgi?19981125180656.A2751>