Date:      Sat, 23 Dec 2017 12:25:41 +0100
From:      "O. Hartmann" <ohartmann@walstatt.org>
To:        Willem Jan Withagen <wjw@digiware.nl>
Cc:        "Rodney W. Grimes" <freebsd-rwg@pdx.rh.CN85.dnsmgr.net>, Cy Schubert <Cy.Schubert@komquats.com>, "O. Hartmann" <ohartmann@walstatt.org>, FreeBSD CURRENT <freebsd-current@freebsd.org>, Freddie Cash <fjwcash@gmail.com>, Alan Somers <asomers@freebsd.org>, "Rodney W. Grimes" <freebsd-rwg@pdx.rh.CN85.dnsmgr.net>, Daniel Kalchev <daniel@digsys.bg>
Subject:   Re: SMART: disk problems on RAIDZ1 pool: (ada6:ahcich6:0:0:0): CAMstatus: ATA Status Error
Message-ID:  <20171223122608.4ea4f097@thor.intern.walstatt.dynvpn.de>
In-Reply-To: <4d58b06a-0dbe-af05-1bd2-e87929e3b7a5@digiware.nl>
References:  <201712131647.vBDGlrf2092528@pdx.rh.CN85.dnsmgr.net> <4d58b06a-0dbe-af05-1bd2-e87929e3b7a5@digiware.nl>

next in thread | previous in thread | raw e-mail | index | archive | help
--Sig_/mdXl02WhP_PB/BOqOogssmV
Content-Type: multipart/mixed; boundary="MP_/4F00pud+2Z/GXgo0SACKCEb"

--MP_/4F00pud+2Z/GXgo0SACKCEb
Content-Type: text/plain; charset=utf-8
Content-Transfer-Encoding: quoted-printable
Content-Disposition: inline

Am Thu, 14 Dec 2017 12:05:20 +0100
Willem Jan Withagen <wjw@digiware.nl> schrieb:

> On 13/12/2017 17:47, Rodney W. Grimes wrote:
> >> On Tue, 12 Dec 2017 14:58:28 -0800
> >> Cy Schubert <Cy.Schubert@komquats.com> wrote:
> >> I think people responding to my thread made it clear that the WD Green
> >> isn't the first-choice-solution for a 20/6 (not 24/7) duty drive and
> >> the fact, that they have serviced now more than 25000 hours, it would
> >> be wise to replace them with alternatives. =20
> >=20
> > I think someone had an apm command that turns off the head park,
> > that would do wonders for drive life.   On the other hand, I think
> > if it was my data and I saw that the drive had 2M head load cycles
> > I would be looking to get out of that driv with any data I could
> > not easily replace.  If it was well backed up or easily replaced
> > my worries would be less. =20
>=20
> WD made their first series of Green disks green by aggressively turning=20
> them into sleep state. Like when few secs there was nog activity they=20
> would park the head, spin it down, and sleep the disk...
> Access would need to undo the whole series of command.
>=20
> This could be reset by writing in one of the disks registers. I remember=
=20
> doing that for my 1,5G WDs (WD15EADS from 2009). That saved a lot of=20
> startups. I still have 'm around, but only use them for things that are=20
> not valuable at all. Some have died over time, but about half of them=20
> still seem to work without much trouble.
>=20
> WD used to have a .exe program to actually do this. But that did not
> work on later disks. And turning things of on those disks was=20
> impossible/a lot more complex.
>=20
> This type of disk worked quite a long time in my ZFS setup. Like a few=20
> years, but I turned parking of as soon as there was a lot of turmoil=20
> about this in the community.
> Now I using WD reds for small ZFS systems, and WD red Pro for large=20
> private storage servers. Professional server get HGST He disks, a bit=20
> more expensive, but very little fallout.
>=20
> --WjW

Hello fellows.

First of all, I managed it over the past week+ to replace all(!) drives wit=
h new ones. I
decided to use this time HGST 4TB Deskstar NAS (HGST HDN726040ALE614) inste=
ad of WD RED
4TB (WDC WD40EFRX-68N32N0). The one WD RED is about to be replaced in the n=
ext days.

Apart from the very long resilvering time (the first drive, the Western Dig=
ital WD RED
4TB with 64MB cache and 5400 rpm) took 11 h, all HGST drives, although cons=
idered faster
(7200 rpm, 128 MB cache) took 15 - 16 h), everything ran smoothly - except,=
 as mentioned,
the exorbitant times of recovery.

A very interesting point in this story is: as you could see, the WD Caviar =
Green 3TB
drives suffered from a high "193 Load_Cycle_Count" - almost 85 per hour. Wh=
en replacing
the drives, I figured out, that one of the four drives was already a Wester=
n Digital RED
3TB NAS drive, but investigating its  "193 Load_Cycle_Count" revealed, that=
 this drive
also had a unusual high reload count - see "smartctl -x" output attached. I=
t seems, as
you already stated, that the APM feature responsible for this isn't availab=
le. The drive
has been purchased Q4/2013.

The HGST drives are very(!) noisy, th ehead movement induces a notable ring=
ing, while the
WD drive(s) are/were really silent. The power consumption of the HGST drive=
s is higher.
But apart from that, I'm disappointed about the fact that WD has also imple=
mented this
"timebomb" Load_Cycle_Count issue.

Thanks a lot for your help and considerations!

Kind regards,
Oliver

--=20
O. Hartmann

Ich widerspreche der Nutzung oder =C3=9Cbermittlung meiner Daten f=C3=BCr
Werbezwecke oder f=C3=BCr die Markt- oder Meinungsforschung (=C2=A7 28 Abs.=
 4 BDSG).

--MP_/4F00pud+2Z/GXgo0SACKCEb
Content-Type: text/plain
Content-Transfer-Encoding: quoted-printable
Content-Disposition: attachment; filename=ada3.txt

smartctl 6.6 2017-11-05 r4594 [FreeBSD 12.0-CURRENT amd64] (local build)
Copyright (C) 2002-17, Bruce Allen, Christian Franke, www.smartmontools.org

=3D=3D=3D START OF INFORMATION SECTION =3D=3D=3D
Model Family:     Western Digital Red
Device Model:     WDC WD30EFRX-68EUZN0
Serial Number:    Seriennummer
LU WWN Device Id: 5 0014ee 0ae56aef0
Firmware Version: 80.00A80
User Capacity:    3,000,592,982,016 bytes [3.00 TB]
Sector Sizes:     512 bytes logical, 4096 bytes physical
Rotation Rate:    5400 rpm
Device is:        In smartctl database [for details use: -P show]
ATA Version is:   ACS-2 (minor revision not indicated)
SATA Version is:  SATA 3.0, 6.0 Gb/s (current: 3.0 Gb/s)
Local Time is:    Sat Dec 23 11:59:30 2017 CET
SMART support is: Available - device has SMART capability.
SMART support is: Enabled
AAM feature is:   Unavailable
APM feature is:   Unavailable
Rd look-ahead is: Enabled
Write cache is:   Enabled
DSN feature is:   Unavailable
ATA Security is:  Disabled, NOT FROZEN [SEC1]
Wt Cache Reorder: Enabled

=3D=3D=3D START OF READ SMART DATA SECTION =3D=3D=3D
SMART overall-health self-assessment test result: PASSED

General SMART Values:
Offline data collection status:  (0x82)	Offline data collection activity
					was completed without error.
					Auto Offline Data Collection: Enabled.
Self-test execution status:      (   0)	The previous self-test routine comp=
leted
					without error or no self-test has ever=20
					been run.
Total time to complete Offline=20
data collection: 		(38760) seconds.
Offline data collection
capabilities: 			 (0x7b) SMART execute Offline immediate.
					Auto Offline data collection on/off support.
					Suspend Offline collection upon new
					command.
					Offline surface scan supported.
					Self-test supported.
					Conveyance Self-test supported.
					Selective Self-test supported.
SMART capabilities:            (0x0003)	Saves SMART data before entering
					power-saving mode.
					Supports SMART auto save timer.
Error logging capability:        (0x01)	Error logging supported.
					General Purpose Logging supported.
Short self-test routine=20
recommended polling time: 	 (   2) minutes.
Extended self-test routine
recommended polling time: 	 ( 389) minutes.
Conveyance self-test routine
recommended polling time: 	 (   5) minutes.
SCT capabilities: 	       (0x703d)	SCT Status supported.
					SCT Error Recovery Control supported.
					SCT Feature Control supported.
					SCT Data Table supported.

SMART Attributes Data Structure revision number: 16
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME          FLAGS    VALUE WORST THRESH FAIL RAW_VALUE
  1 Raw_Read_Error_Rate     POSR-K   200   200   051    -    0
  3 Spin_Up_Time            POS--K   171   165   021    -    6416
  4 Start_Stop_Count        -O--CK   099   099   000    -    1860
  5 Reallocated_Sector_Ct   PO--CK   200   200   140    -    0
  7 Seek_Error_Rate         -OSR-K   200   200   000    -    0
  9 Power_On_Hours          -O--CK   072   072   000    -    20809
 10 Spin_Retry_Count        -O--CK   100   100   000    -    0
 11 Calibration_Retry_Count -O--CK   100   100   000    -    0
 12 Power_Cycle_Count       -O--CK   099   099   000    -    1858
192 Power-Off_Retract_Count -O--CK   200   200   000    -    112
193 Load_Cycle_Count        -O--CK   001   001   000    -    1974142
194 Temperature_Celsius     -O---K   128   109   000    -    22
196 Reallocated_Event_Count -O--CK   200   200   000    -    0
197 Current_Pending_Sector  -O--CK   200   200   000    -    0
198 Offline_Uncorrectable   ----CK   200   200   000    -    0
199 UDMA_CRC_Error_Count    -O--CK   200   200   000    -    0
200 Multi_Zone_Error_Rate   ---R--   200   200   000    -    0
                            ||||||_ K auto-keep
                            |||||__ C event count
                            ||||___ R error rate
                            |||____ S speed/performance
                            ||_____ O updated online
                            |______ P prefailure warning

General Purpose Log Directory Version 1
SMART           Log Directory Version 1 [multi-sector log support]
Address    Access  R/W   Size  Description
0x00       GPL,SL  R/O      1  Log Directory
0x01           SL  R/O      1  Summary SMART error log
0x02           SL  R/O      5  Comprehensive SMART error log
0x03       GPL     R/O      6  Ext. Comprehensive SMART error log
0x06           SL  R/O      1  SMART self-test log
0x07       GPL     R/O      1  Extended self-test log
0x09           SL  R/W      1  Selective self-test log
0x10       GPL     R/O      1  NCQ Command Error log
0x11       GPL     R/O      1  SATA Phy Event Counters log
0x21       GPL     R/O      1  Write stream error log
0x22       GPL     R/O      1  Read stream error log
0x80-0x9f  GPL,SL  R/W     16  Host vendor specific log
0xa0-0xa7  GPL,SL  VS      16  Device vendor specific log
0xa8-0xb7  GPL,SL  VS       1  Device vendor specific log
0xbd       GPL,SL  VS       1  Device vendor specific log
0xc0       GPL,SL  VS       1  Device vendor specific log
0xc1       GPL     VS      93  Device vendor specific log
0xe0       GPL,SL  R/W      1  SCT Command/Status
0xe1       GPL,SL  R/W      1  SCT Data Transfer

SMART Extended Comprehensive Error Log Version: 1 (6 sectors)
Device Error Count: 7
	CR     =3D Command Register
	FEATR  =3D Features Register
	COUNT  =3D Count (was: Sector Count) Register
	LBA_48 =3D Upper bytes of LBA High/Mid/Low Registers ]  ATA-8
	LH     =3D LBA High (was: Cylinder High) Register    ]   LBA
	LM     =3D LBA Mid (was: Cylinder Low) Register      ] Register
	LL     =3D LBA Low (was: Sector Number) Register     ]
	DV     =3D Device (was: Device/Head) Register
	DC     =3D Device Control Register
	ER     =3D Error register
	ST     =3D Status register
Powered_Up_Time is measured from power on, and printed as
DDd+hh:mm:SS.sss where DD=3Ddays, hh=3Dhours, mm=3Dminutes,
SS=3Dsec, and sss=3Dmillisec. It "wraps" after 49.710 days.

Error 7 [6] occurred at disk power-on lifetime: 16151 hours (672 days + 23 =
hours)
  When the command that caused the error occurred, the device was active or=
 idle.

  After command completion occurred, registers were:
  ER -- ST COUNT  LBA_48  LH LM LL DV DC
  -- -- -- =3D=3D -- =3D=3D =3D=3D =3D=3D -- -- -- -- --
  10 -- 51 00 00 00 00 98 01 cd d0 40 00  Error: IDNF at LBA =3D 0x9801cdd0=
 =3D 2550255056

  Commands leading to the command that caused the error were:
  CR FEATR COUNT  LBA_48  LH LM LL DV DC  Powered_Up_Time  Command/Feature_=
Name
  -- =3D=3D -- =3D=3D -- =3D=3D =3D=3D =3D=3D -- -- -- -- --  -------------=
--  --------------------
  61 00 08 00 50 00 00 98 01 cd d0 40 08     00:12:14.943  WRITE FPDMA QUEU=
ED
  ea 00 00 00 00 00 00 00 00 00 00 40 08     00:12:05.025  FLUSH CACHE EXT
  61 00 08 00 40 00 01 5d 50 9f a0 40 08     00:12:05.024  WRITE FPDMA QUEU=
ED
  61 00 08 00 38 00 01 5d 50 9d a0 40 08     00:12:05.024  WRITE FPDMA QUEU=
ED
  61 00 08 00 30 00 00 00 00 13 a0 40 08     00:12:05.024  WRITE FPDMA QUEU=
ED

Error 6 [5] occurred at disk power-on lifetime: 10875 hours (453 days + 3 h=
ours)
  When the command that caused the error occurred, the device was active or=
 idle.

  After command completion occurred, registers were:
  ER -- ST COUNT  LBA_48  LH LM LL DV DC
  -- -- -- =3D=3D -- =3D=3D =3D=3D =3D=3D -- -- -- -- --
  10 -- 51 00 00 00 01 30 01 ce 78 40 00  Error: IDNF at LBA =3D 0x13001ce7=
8 =3D 5100392056

  Commands leading to the command that caused the error were:
  CR FEATR COUNT  LBA_48  LH LM LL DV DC  Powered_Up_Time  Command/Feature_=
Name
  -- =3D=3D -- =3D=3D -- =3D=3D =3D=3D =3D=3D -- -- -- -- --  -------------=
--  --------------------
  61 00 08 00 b0 00 01 30 01 ce 78 40 08     04:06:34.288  WRITE FPDMA QUEU=
ED
  ea 00 00 00 00 00 00 00 00 00 00 40 08     04:06:24.234  FLUSH CACHE EXT
  61 00 08 00 a0 00 01 5d 50 9f 30 40 08     04:06:24.234  WRITE FPDMA QUEU=
ED
  61 00 08 00 98 00 01 5d 50 9d 30 40 08     04:06:24.234  WRITE FPDMA QUEU=
ED
  61 00 08 00 90 00 00 00 00 13 30 40 08     04:06:24.233  WRITE FPDMA QUEU=
ED

Error 5 [4] occurred at disk power-on lifetime: 8417 hours (350 days + 17 h=
ours)
  When the command that caused the error occurred, the device was active or=
 idle.

  After command completion occurred, registers were:
  ER -- ST COUNT  LBA_48  LH LM LL DV DC
  -- -- -- =3D=3D -- =3D=3D =3D=3D =3D=3D -- -- -- -- --
  10 -- 51 00 00 00 00 c4 06 ba 08 40 00  Error: IDNF at LBA =3D 0xc406ba08=
 =3D 3288775176

  Commands leading to the command that caused the error were:
  CR FEATR COUNT  LBA_48  LH LM LL DV DC  Powered_Up_Time  Command/Feature_=
Name
  -- =3D=3D -- =3D=3D -- =3D=3D =3D=3D =3D=3D -- -- -- -- --  -------------=
--  --------------------
  61 00 08 00 a8 00 00 c4 06 ba 08 40 08     00:45:57.190  WRITE FPDMA QUEU=
ED
  ea 00 00 00 00 00 00 00 00 00 00 40 08     00:45:47.264  FLUSH CACHE EXT
  61 00 08 00 98 00 01 5d 50 9f b0 40 08     00:45:47.263  WRITE FPDMA QUEU=
ED
  61 00 08 00 90 00 01 5d 50 9d b0 40 08     00:45:47.263  WRITE FPDMA QUEU=
ED
  61 00 08 00 88 00 00 00 00 13 b0 40 08     00:45:47.263  WRITE FPDMA QUEU=
ED

Error 4 [3] occurred at disk power-on lifetime: 3423 hours (142 days + 15 h=
ours)
  When the command that caused the error occurred, the device was active or=
 idle.

  After command completion occurred, registers were:
  ER -- ST COUNT  LBA_48  LH LM LL DV DC
  -- -- -- =3D=3D -- =3D=3D =3D=3D =3D=3D -- -- -- -- --
  10 -- 51 00 00 00 00 b2 59 f6 a8 40 00  Error: IDNF at LBA =3D 0xb259f6a8=
 =3D 2992240296

  Commands leading to the command that caused the error were:
  CR FEATR COUNT  LBA_48  LH LM LL DV DC  Powered_Up_Time  Command/Feature_=
Name
  -- =3D=3D -- =3D=3D -- =3D=3D =3D=3D =3D=3D -- -- -- -- --  -------------=
--  --------------------
  61 00 08 00 f8 00 00 b2 59 f6 a8 40 08     12:09:22.415  WRITE FPDMA QUEU=
ED
  ea 00 00 00 00 00 00 00 00 00 00 40 08     12:09:13.160  FLUSH CACHE EXT
  61 00 08 00 f8 00 01 5d 50 9f 90 40 08     12:09:13.159  WRITE FPDMA QUEU=
ED
  61 00 08 00 f0 00 01 5d 50 9d 90 40 08     12:09:13.159  WRITE FPDMA QUEU=
ED
  61 00 08 00 e8 00 00 00 00 13 90 40 08     12:09:13.159  WRITE FPDMA QUEU=
ED

Error 3 [2] occurred at disk power-on lifetime: 2928 hours (122 days + 0 ho=
urs)
  When the command that caused the error occurred, the device was active or=
 idle.

  After command completion occurred, registers were:
  ER -- ST COUNT  LBA_48  LH LM LL DV DC
  -- -- -- =3D=3D -- =3D=3D =3D=3D =3D=3D -- -- -- -- --
  10 -- 51 00 00 00 00 c0 05 10 20 40 00  Error: IDNF at LBA =3D 0xc0051020=
 =3D 3221557280

  Commands leading to the command that caused the error were:
  CR FEATR COUNT  LBA_48  LH LM LL DV DC  Powered_Up_Time  Command/Feature_=
Name
  -- =3D=3D -- =3D=3D -- =3D=3D =3D=3D =3D=3D -- -- -- -- --  -------------=
--  --------------------
  61 00 08 00 00 00 00 c0 05 10 20 40 08     09:36:05.067  WRITE FPDMA QUEU=
ED
  61 00 08 00 00 00 01 5d 50 9f f0 40 08     09:35:50.674  WRITE FPDMA QUEU=
ED
  61 00 08 00 f8 00 01 5d 50 9d f0 40 08     09:35:50.674  WRITE FPDMA QUEU=
ED
  61 00 08 00 f0 00 00 00 00 13 f0 40 08     09:35:50.674  WRITE FPDMA QUEU=
ED
  61 00 08 00 e8 00 00 00 00 11 f0 40 08     09:35:50.674  WRITE FPDMA QUEU=
ED

Error 2 [1] occurred at disk power-on lifetime: 1989 hours (82 days + 21 ho=
urs)
  When the command that caused the error occurred, the device was active or=
 idle.

  After command completion occurred, registers were:
  ER -- ST COUNT  LBA_48  LH LM LL DV DC
  -- -- -- =3D=3D -- =3D=3D =3D=3D =3D=3D -- -- -- -- --
  10 -- 51 00 00 00 00 ae 07 ce 30 40 00  Error: IDNF at LBA =3D 0xae07ce30=
 =3D 2919747120

  Commands leading to the command that caused the error were:
  CR FEATR COUNT  LBA_48  LH LM LL DV DC  Powered_Up_Time  Command/Feature_=
Name
  -- =3D=3D -- =3D=3D -- =3D=3D =3D=3D =3D=3D -- -- -- -- --  -------------=
--  --------------------
  61 00 08 00 78 00 00 ae 07 ce 30 40 08     04:16:19.349  WRITE FPDMA QUEU=
ED
  61 00 08 00 78 00 01 5d 50 9f 98 40 08     04:16:05.011  WRITE FPDMA QUEU=
ED
  61 00 08 00 70 00 01 5d 50 9d 98 40 08     04:16:05.011  WRITE FPDMA QUEU=
ED
  61 00 08 00 68 00 00 00 00 13 98 40 08     04:16:05.011  WRITE FPDMA QUEU=
ED
  61 00 08 00 60 00 00 00 00 11 98 40 08     04:16:05.011  WRITE FPDMA QUEU=
ED

Error 1 [0] occurred at disk power-on lifetime: 1764 hours (73 days + 12 ho=
urs)
  When the command that caused the error occurred, the device was active or=
 idle.

  After command completion occurred, registers were:
  ER -- ST COUNT  LBA_48  LH LM LL DV DC
  -- -- -- =3D=3D -- =3D=3D =3D=3D =3D=3D -- -- -- -- --
  10 -- 51 00 00 00 00 aa 1a 86 e8 40 00  Error: IDNF at LBA =3D 0xaa1a86e8=
 =3D 2853865192

  Commands leading to the command that caused the error were:
  CR FEATR COUNT  LBA_48  LH LM LL DV DC  Powered_Up_Time  Command/Feature_=
Name
  -- =3D=3D -- =3D=3D -- =3D=3D =3D=3D =3D=3D -- -- -- -- --  -------------=
--  --------------------
  61 00 08 00 d0 00 00 aa 1a 86 e8 40 08     12:13:30.211  WRITE FPDMA QUEU=
ED
  61 00 08 00 d0 00 01 5d 50 9f 30 40 08     12:13:20.248  WRITE FPDMA QUEU=
ED
  61 00 08 00 c8 00 01 5d 50 9d 30 40 08     12:13:20.248  WRITE FPDMA QUEU=
ED
  61 00 08 00 c0 00 00 00 00 13 30 40 08     12:13:20.248  WRITE FPDMA QUEU=
ED
  61 00 08 00 b8 00 00 00 00 11 30 40 08     12:13:20.248  WRITE FPDMA QUEU=
ED

SMART Extended Self-test Log Version: 1 (1 sectors)
Num  Test_Description    Status                  Remaining  LifeTime(hours)=
  LBA_of_first_error
# 1  Short offline       Completed without error       00%     18023       =
  -
# 2  Short offline       Completed without error       00%      2620       =
  -

SMART Selective self-test log data structure revision number 1
 SPAN  MIN_LBA  MAX_LBA  CURRENT_TEST_STATUS
    1        0        0  Not_testing
    2        0        0  Not_testing
    3        0        0  Not_testing
    4        0        0  Not_testing
    5        0        0  Not_testing
Selective self-test flags (0x0):
  After scanning selected spans, do NOT read-scan remainder of disk.
If Selective self-test is pending on power-up, resume after 0 minute delay.

SCT Status Version:                  3
SCT Version (vendor specific):       258 (0x0102)
SCT Support Level:                   1
Device State:                        Active (0)
Current Temperature:                    22 Celsius
Power Cycle Min/Max Temperature:     22/22 Celsius
Lifetime    Min/Max Temperature:     11/41 Celsius
Under/Over Temperature Limit Count:   0/0
Vendor specific:
01 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00

SCT Temperature History Version:     2
Temperature Sampling Period:         1 minute
Temperature Logging Interval:        1 minute
Min/Max recommended Temperature:      0/60 Celsius
Min/Max Temperature Limit:           -41/85 Celsius
Temperature History Size (Index):    478 (301)

Index    Estimated Time   Temperature Celsius
 302    2017-12-23 04:01    22  ***
 ...    ..( 92 skipped).    ..  ***
 395    2017-12-23 05:34    22  ***
 396    2017-12-23 05:35    21  **
 ...    ..( 93 skipped).    ..  **
  12    2017-12-23 07:09    21  **
  13    2017-12-23 07:10    22  ***
 ...    ..( 92 skipped).    ..  ***
 106    2017-12-23 08:43    22  ***
 107    2017-12-23 08:44     ?  -
 108    2017-12-23 08:45    21  **
 ...    ..( 29 skipped).    ..  **
 138    2017-12-23 09:15    21  **
 139    2017-12-23 09:16    22  ***
 ...    ..( 21 skipped).    ..  ***
 161    2017-12-23 09:38    22  ***
 162    2017-12-23 09:39     ?  -
 163    2017-12-23 09:40    15  -
 164    2017-12-23 09:41    15  -
 165    2017-12-23 09:42    16  -
 166    2017-12-23 09:43    16  -
 167    2017-12-23 09:44    17  -
 ...    ..(  5 skipped).    ..  -
 173    2017-12-23 09:50    17  -
 174    2017-12-23 09:51    18  -
 ...    ..(  9 skipped).    ..  -
 184    2017-12-23 10:01    18  -
 185    2017-12-23 10:02    19  -
 ...    ..(  7 skipped).    ..  -
 193    2017-12-23 10:10    19  -
 194    2017-12-23 10:11    20  *
 ...    ..( 13 skipped).    ..  *
 208    2017-12-23 10:25    20  *
 209    2017-12-23 10:26    21  **
 ...    ..( 50 skipped).    ..  **
 260    2017-12-23 11:17    21  **
 261    2017-12-23 11:18     ?  -
 262    2017-12-23 11:19    13  -
 263    2017-12-23 11:20    13  -
 264    2017-12-23 11:21    14  -
 ...    ..(  2 skipped).    ..  -
 267    2017-12-23 11:24    14  -
 268    2017-12-23 11:25    15  -
 269    2017-12-23 11:26    15  -
 270    2017-12-23 11:27    16  -
 271    2017-12-23 11:28    16  -
 272    2017-12-23 11:29    17  -
 ...    ..(  4 skipped).    ..  -
 277    2017-12-23 11:34    17  -
 278    2017-12-23 11:35    18  -
 279    2017-12-23 11:36     ?  -
 280    2017-12-23 11:37    22  ***
 ...    ..( 20 skipped).    ..  ***
 301    2017-12-23 11:58    22  ***

SCT Error Recovery Control:
           Read:     70 (7.0 seconds)
          Write:     70 (7.0 seconds)

Device Statistics (GP/SMART Log 0x04) not supported

Pending Defects log (GP Log 0x0c) not supported

SATA Phy Event Counters (GP Log 0x11)
ID      Size     Value  Description
0x0001  2            0  Command failed due to ICRC error
0x0002  2            0  R_ERR response for data FIS
0x0003  2            0  R_ERR response for device-to-host data FIS
0x0004  2            0  R_ERR response for host-to-device data FIS
0x0005  2            0  R_ERR response for non-data FIS
0x0006  2            0  R_ERR response for device-to-host non-data FIS
0x0007  2            0  R_ERR response for host-to-device non-data FIS
0x0008  2            0  Device-to-host non-data FIS retries
0x0009  2            1  Transition from drive PhyRdy to drive PhyNRdy
0x000a  2            1  Device-to-host register FISes sent due to a COMRESET
0x000b  2            0  CRC errors within host-to-device FIS
0x000f  2            0  R_ERR response for host-to-device data FIS, CRC
0x0012  2            0  R_ERR response for host-to-device non-data FIS, CRC
0x8000  4          911  Vendor specific


--MP_/4F00pud+2Z/GXgo0SACKCEb--

--Sig_/mdXl02WhP_PB/BOqOogssmV
Content-Type: application/pgp-signature
Content-Description: OpenPGP digital signature

-----BEGIN PGP SIGNATURE-----

iLUEARMKAB0WIQQZVZMzAtwC2T/86TrS528fyFhYlAUCWj49UAAKCRDS528fyFhY
lFXHAf4iBVK6BUfo1fH//mGlWP5OpL6cSFmFPT00k+3uPWqR/PU2BRrCTalDXFRx
rVO0b7UNBt6tBLBylvTBtcfjCx75Af4l/rTR42dmRiyGUXWf55Y+jiX52PfrhRBL
44zSdBOAk44ejHU8MUV84SI6TYDcI22Di/yf4hhReLZRkV4iP/ia
=WeZR
-----END PGP SIGNATURE-----

--Sig_/mdXl02WhP_PB/BOqOogssmV--



Want to link to this message? Use this URL: <https://mail-archive.FreeBSD.org/cgi/mid.cgi?20171223122608.4ea4f097>