Date: Fri, 24 Aug 2007 10:31:15 +0100 From: "Clayton Milos" <clay@milos.za.net> To: <freebsd-stable@freebsd.org> Subject: Re: A little story of failed raid5 (3ware 8000 series) Message-ID: <00c801c7e631$85e3e700$0701a8c0@claylaptop> References: <MDEHLPKNGKAHNMBLJOLKCENEGEAC.davids@webmaster.com><02fe01c7e3af$d3b86ed0$0c00a8c0@Artem> <20070824095702.6fe7ee3c@mablung.edhellond.fbi.ie>
next in thread | previous in thread | raw e-mail | index | archive | help
> On Tue, 21 Aug 2007 08:57:22 +0400 > "Artem Kuchin" <matrix@itlegion.ru> wrote: > >> Um.. it is because i did not have a map of hot swap baskets to >> conroller ports and i needed to check every driver basket to >> understand which port it sits on. I have no choise, i think. >> > > I'm just going to highlight the importance of knowing which > physical disk is which on your system. > > About a year ago I had to replace a hot-swappable disk from an > array, but then realised I had no idea which physical disk it > was as the map of the disks was rather helpfully *inside* the > case. Due to the physical setup, I had no way or removing the > cover without first powering down the server - which defeated > the whole point of paying extra for hot-swap disks. > > So yeah, be sure to label your disk bays, but be sure to put > those labels somewhere *useful*. > > -fr. > Useful like on the front of the drive bays ;-) The Areca cards have a nice function called drive identify that lights up the selected drive's LED. I think the 3ware cards have it too. -Clay
Want to link to this message? Use this URL: <https://mail-archive.FreeBSD.org/cgi/mid.cgi?00c801c7e631$85e3e700$0701a8c0>