On 05.09.2018 20:19, Allan Jude wrote:

>>  I want to have my serial console 115200 (of course), *including* BIOS
>> redirection (which goes before boot0sio).
>>
>>  But boot0sio supports only speeds up to 9600 (due to int 14h limitations).
>>
>>  Is it possible to solve this clash somehow?
> 
> /boot/loader reads /boot.config where you can put -S115200
 I think, /boot/boot reads /boot.config, and it works for me.

 My question is somewhat more tricky: I have 115200 BEFORE boot0sio
(from BIOS) and I have 115200 AFTER boot0sio (from /boot/boot and
/boot/loader later). And I want to see "F1 / F2" boot selection from
boot0sio.

-- 