Date: Tue, 17 Sep 1996 14:16:56 GMT From: Dayton Clark <dayton@holiday.sci.brooklyn.cuny.edu> To: dufault@hda.com Cc: questions@freebsd.org, pencil@holiday.sci.brooklyn.cuny.edu Subject: LabPC+ problem Message-ID: <199609171416.OAA27952@holiday.sci.brooklyn.cuny.edu>
next in thread | raw e-mail | index | archive | help
Hello, We're using the labpc driver with FreeBSD 2.1R. The system is a straight forward 486/33 with ISA bus. The board is a LabPC+. We are doing digital output and analog input simultaneously. When we read a single channel (channel 0) it works fine. When we scan channels 7 - 0 we seem to get channel 0 values for all channels. Our application is not very demanding as to sampling rate. We did have to defeat the multiple open lockout to open the device twice. Is the the likely cause of the problem? :) We need to overcome this problem and we're willing and able to work on it. The real questions are: a) Are we trying to do something the BOARD can't do? b) Are we trying to do something the DRIVER (as is) can't do? c) Should we continue to suspect our user-side code? If a) is correct, we'll be verry disappointed. I'm bleary eyed from investigating c). I suspect that b) is correct. If we are to venture further into the driver, do you have any words of wisdom on as to how to overcome the problem? A specific question is: why is the multi-open lockout necessary? thanks dayton Dayton Clark CIS Department dayton@brooklyn.cuny.edu Brooklyn College/CUNY 1-718-951-4811 Brooklyn, New York 11210 1-718-951-4842 (fax)