I'm having trouble getting a 3Com ethernet card to work with pccardd
in my Gateway 5100.  It works fine with the zp0 driver compiled into
the kernel.  However, I recently got a modem, so I'm trying to get
pccardd to work.

After enabling DEBUG in pccardd, I get (in /var/log/pccardd.debug,
removing the date/time stamps):

----------
kenmare pccardd[946]: mem=0xd4000 
kenmare pccardd[946]: Using I/O addr 0x240, size 16 
kenmare pccardd[946]: Setting config reg at offs 0x10000 to 0x41, Reset time = 50 ms 
kenmare pccardd[946]: Assigning I/O window 0, start 0x240, size 0x10 flags 0x7 
kenmare pccardd[946]: Assign zp0, io 0x240, mem 0x0, 0 bytes, irq 10, flags 80 
kenmare pccardd[946]: driver allocation failed for 3Com Corporation
kenmare pccardd[946]: State same as before, continuing anyway
kenmare pccardd[946]: pccardd started
kenmare pccardd[946]: Found existing driver (zp0) for 3Com Corporation 
kenmare pccardd[946]: Using I/O addr 0x240, size 16 
kenmare pccardd[946]: Setting config reg at offs 0x10000 to 0x41, Reset time = 50 ms 
kenmare pccardd[946]: Assigning I/O window 0, start 0x240, size 0x10 flags 0x7 
kenmare pccardd[946]: Assign zp0, io 0x240, mem 0x0, 0 bytes, irq 10, flags 80 
kenmare pccardd[946]: driver allocation failed for 3Com Corporation
----------

My pccard.conf is:

----------
# Generally available IO ports
io	0x240-0x360
# Generally available IRQs (Built-in sound-card owners remove 5)
irq	3 10 11 13 15
# Available memory slots
memory	0xd4000  96k

# 3Com Etherlink III 3C589D
card "3Com Corporation" "3C589D"
	config	0x1 "zp0" 10
	insert	echo 3Com Corporation inserted
	insert	/etc/pccard_ether zp0
	remove	echo 3Com Etherlink III removed
	remove	/sbin/ifconfig zp0 delete

# 3com/USR/Megahertz 3CCM556
card "3Com" "3CXM/3CCM556"
	config 0x23 "sio2" ?
	insert echo 3Com PCMCIA 56K Modem inserted
	remove echo 3Com PCMCIA 56K Modem removed
----------

And the output of "pccardc dumpcis" is:

----------
Configuration data for card in slot 0
Tuple #1, code = 0x1 (Common memory descriptor), length = 2
    000:  00 ff
	Common memory device information:
		Device number 1, type No device, WPS = OFF
		Speed = No speed, Memory block size = reserved, 32 units
Tuple #2, code = 0x17 (Attribute memory descriptor), length = 3
    000:  43 02 ff
	Attribute memory device information:
		Device number 1, type EEPROM, WPS = OFF
		Speed = 150nS, Memory block size = 8Kb, 1 units
Tuple #3, code = 0x20 (Manufacturer ID), length = 4
    000:  01 01 89 05
	PCMCIA ID = 0x101, OEM ID = 0x589
Tuple #4, code = 0x21 (Functional ID), length = 2
    000:  06 00
	Network/LAN adapter
Tuple #5, code = 0x15 (Version 1 info), length = 58
    000:  04 01 33 43 6f 6d 20 43 6f 72 70 6f 72 61 74 69
    010:  6f 6e 00 33 43 35 38 39 44 00 54 50 2f 42 4e 43
    020:  20 4c 41 4e 20 43 61 72 64 20 56 65 72 2e 20 32
    030:  61 00 30 30 30 30 30 32 00 ff
	Version = 4.1, Manuf = [3Com Corporation],card vers = [3C589D]
	Addit. info = [TP/BNC LAN Card Ver. 2a],[000002]
Tuple #6, code = 0x1a (Configuration map), length = 6
    000:  02 03 00 00 01 03
	Reg len = 3, config register addr = 0x10000, last config = 0x3
	Registers: XX------ 
Tuple #7, code = 0x1b (Configuration entry), length = 15
    000:  c1 01 1d 71 55 35 55 54 e0 72 5d 64 30 ff ff
	Config index = 0x1(default)
	Interface byte = 0x1 (I/O)
	Vcc pwr:
		Nominal operating supply voltage: 5 x 1V
		Max current average over 1 second: 3 x 10mA
		Max current average over 10 ms: 5 x 10mA
		Power down supply current: 5 x 1mA
	Wait scale Speed = 7.0 x 100 ns
	RDY/BSY scale Speed = 7.0 x 100 ns
	Card decodes 18 address lines, full 8/16 Bit I/O
		IRQ modes: Level, Pulse
		IRQs:  IOCK 1 4 5 6 8 10 11 12 14
Tuple #8, code = 0x1b (Configuration entry), length = 7
    000:  03 01 71 55 26 26 54
	Config index = 0x3
	Vcc pwr:
		Nominal operating supply voltage: 5 x 1V
		Max current average over 1 second: 2 x 100mA
		Max current average over 10 ms: 2 x 100mA
		Power down supply current: 5 x 1mA
Tuple #9, code = 0x19 (JEDEC descr for attribute memory), length = 3
    000:  00 00 ff
Tuple #10, code = 0x14 (No link), length = 0
Tuple #11, code = 0x10 (Checksum), length = 5
    000:  88 ff 81 00 00
	Checksum from offset -120, length 129, value is 0x0
Tuple #12, code = 0xff (Terminator), length = 149
    000:  00 03 83 00 fd ff ff ff ff ff ff ff ff ff ff ff
    010:  ff ff ff ff ff ff ff ff ff ff ff ff ff ff ff ff
    020:  ff ff ff ff ff ff ff ff ff ff ff ff ff ff ff ff
    030:  ff ff ff ff ff ff ff ff ff ff ff ff ff ff ff ff
    040:  ff ff ff ff ff ff ff ff ff ff ff ff ff ff ff ff
    050:  ff ff ff ff ff ff ff ff ff ff ff ff ff ff ff ff
    060:  ff ff ff ff ff ff ff ff ff ff ff ff ff ff ff ff
    070:  ff ff ff ff ff ff ff ff ff ff ff ff ff ff ff ff
    080:  ff ff ff ff ff ff ff ff ff ff ff ff ff ff ff ff
    090:  ff ff ff ff ff
2 slots found
----------

Any suggestions as to how to get this working?