Date:      Sat, 06 Nov 1999 19:27:20 +0100
From:      Mattias Pantzare <pantzer@ludd.luth.se>
To:        Bernd Walter <ticso@cicely.de>
Cc:        freebsd-fs@FreeBSD.ORG
Subject:   Re: RAID-5 and failure 
Message-ID:  <199911061827.TAA22113@zed.ludd.luth.se>
In-Reply-To: Message from Bernd Walter <ticso@cicely.de>  of "Sat, 06 Nov 1999 18:33:16 %2B0100." <19991106183316.A9420@cicely7.cicely.de> 

next in thread | previous in thread | raw e-mail | index | archive | help
> If the system panics or power fails between such a write there is no wa=
y to
> find out if the parity is broken beside verifying the complete plex aft=
er
> reboot - the problem should be the same with all usual hard and softwar=
e
> solutions - greg already begun or finished recalculating and checking t=
he
> parity.

This is realy a optimisation issue, if you just write without using
two-phase commit then you have to recalculate parity after a powerfailure=
=2E =

(One might keep track of the regions of the disk that have had writes lat=
ly =

and only recalculate them)

Or you do as it says under Two-phase commitment in
http://www.sunworld.com/sunworldonline/swol-09-1995/swol-09-raid5-2.html.=





To Unsubscribe: send mail to majordomo@FreeBSD.org
with "unsubscribe freebsd-fs" in the body of the message