Date: Mon, 08 May 2006 09:47:11 +0100 From: Karl Pielorz <kpielorz@tdx.co.uk> To: freebsd-scsi@freebsd.org Subject: 6.1RC-2 ciss Driver hangs on Rebuild for Internal Drives with external MSA20 attached Message-ID: <39E0E0A8ACF54E31B690E879@unsupported>
next in thread | raw e-mail | index | archive | help
Hi All, We've recently added an MSA20 external SATA enclosure to our HP Proliant DL380 server. While testing, we found the following problem: If you fail an internal RAID array, when the system starts rebuilding it - any disk access to ciss0 will 'hang' - killing the server. The rebuild does complete OK (guess that's the controller continuing to do it in-background) - but the machine never recovers from the hang. If you remove the MSA20 - internal drives can be failed, and will rebuild fine. Additionally - if you fail a drive in the MSA20 when it's attached - it will fail, and rebuild perfectly Ok (no hangs). I've also noticed the following appears logged, when the machine is going to hang: " ciss0: ** Hot-plug drive inserted: SCSI port 2 ID 5 ciss0: ** State change, logical drive 2 [server hangs at this point - after ~30 sec you get...] ciss0: error sending 195 LUN command (35) <---- Presumably not good :) ciss0: Warning, cannot get physical lun list ciss0: logical drive 2 (da2) changed status interim recovery->ready for recovery, spare status 0x0 " Any suggestions? - We've checked the firmware on both the server, and the MSA20 is the latest. The cable is the HP supplied one. Thanks, -Karl You can find a full verbose boot for this machine, admittedly under 6.1RC1 (which had the same problem) at: http://www.tdx.com/verbose_6.1rc1.txt
Want to link to this message? Use this URL: <https://mail-archive.FreeBSD.org/cgi/mid.cgi?39E0E0A8ACF54E31B690E879>