L.S.
I submitted a bugreport & patch for 3.3 /4.1 a year ago, but on
installing 4.4 a while back, I found it had not been incorporated.
Here it is again as a diff to 4.4. Please apply.
Regards,
Wouter
[-- Attachment #2 --]
--- /usr/src/sys/cam/scsi/scsi_da.c.orig Mon Jul 30 02:48:20 2001
+++ /usr/src/sys/cam/scsi/scsi_da.c Sat Sep 29 00:15:23 2001
@@ -142,6 +142,29 @@
{
{
/*
+ * Fujitsu M2513A MO drives don't like the synchronize cache command.
+ * Tested devices: M2513A2 firmware versions 1200 & 1300.
+ *
+ * Note that these drives can report as either optical memory
+ * or direct access device (dip switch).
+ *
+ * W.Scholten <wouter.scholten@wanadoo.nl>
+ */
+ {T_DIRECT, SIP_MEDIA_REMOVABLE, "FUJITSU", "M2513A", "*"},
+ /*quirks*/ DA_Q_NO_SYNC_CACHE
+ },
+ {
+ /*
+ * Fujitsu M2513A MO drive DA_Q_NO_SYNC_CACHE quirk. Optical device.
+ * (see accompanying 'direct access device' entry above)
+ */
+ {T_OPTICAL, SIP_MEDIA_REMOVABLE, "FUJITSU", "M2513A", "*"},
+ /*quirks*/ DA_Q_NO_SYNC_CACHE
+ },
+
+
+ {
+ /*
* This particular Fujitsu drive doesn't like the
* synchronize cache command.
* Reported by: Tom Jackson <toj@gorilla.net>