Date: Fri, 23 Jun 2006 20:40:30 +0100 From: "Joao Barros" <joao.barros@gmail.com> To: "Alex Franks" <arfranks@gmail.com> Cc: freebsd-questions@freebsd.org Subject: Re: Hot-Swapping hard drives on Dell PowerEdge 2850 running FBSD 5.5-PRE Message-ID: <70e8236f0606231240t77e1b510xd5ecd98c093af559@mail.gmail.com> In-Reply-To: <2f488c030606231113i2b9b4bdcsa1b4192be54b9011@mail.gmail.com> References: <2f488c030606221106q4183de17gbff80d696f704505@mail.gmail.com> <449BAE45.7030705@dial.pipex.com> <2f488c030606231113i2b9b4bdcsa1b4192be54b9011@mail.gmail.com>
next in thread | previous in thread | raw e-mail | index | archive | help
On 6/23/06, Alex Franks <arfranks@gmail.com> wrote: > The controller is a Perc 4e/Di as assumed, and I'm still a little > unsure as to whether the 2 drives that shipped with the machine are > currently set up in a RAID array. The current filesystem is mounted on > /dev/amrd0s1[a-f] and I would expect to find the new drives named > similarly after using some useful utility that I'm unaware of. Any > thoughts? > > Thanks again. > Alex Try amrstat from ports which will show you something like this: Logical volume 0 optimal (101.60 GB, RAID5) Physical drive 0:0 online Physical drive 0:1 online Physical drive 1:0 online Physical drive 1:2 online Physical drive 1:4 hotspare -- Joao Barros