> What is your server system? Make/model/ram/etc.
Intel(R) Xeon(R) CPU E5-2603 v4 @ 1.70GHz (6 cores, a little starved
on the clock but the load at least is basically zero during this test)
128GB of memory

> top -aH
During the copy load (for brevity, only did the real top contenders
for CPU here):

last pid: 15560;  load averages:  0.25,  0.39,  0.27



                                                         up 4+15:48:54
 09:17:38
98 threads:    2 running, 96 sleeping
CPU:  0.0% user,  0.0% nice, 19.1% system,  5.6% interrupt, 75.3% idle
Mem: 12M Active, 4405M Inact, 8284K Laundry, 115G Wired, 1148M Buf, 4819M Free
ARC: 98G Total, 80G MFU, 15G MRU, 772K Anon, 1235M Header, 1042M Other
     91G Compressed, 189G Uncompressed, 2.09:1 Ratio
Swap: 5120M Total, 5120M Free

  PID USERNAME    PRI NICE   SIZE    RES STATE    C   TIME    WCPU COMMAND
 3830 root         20    0    12M  2700K rpcsvc   2   1:16  53.26%
nfsd: server (nfsd){nfsd: service}
 3830 root         20    0    12M  2700K CPU5     5   5:42  52.96%
nfsd: server (nfsd){nfsd: master}
15560 adam         20    0    17M  5176K CPU2     2   0:00   0.12% top -aH
 1493 root         20    0    13M  2260K select   3   0:36   0.01%
/usr/sbin/powerd
 1444 root         20    0    75M  2964K select   5   0:19   0.01%
/usr/sbin/mountd -r /etc/exports /etc/zfs/exports
 1215 uucp         20    0    13M  2820K select   5   0:27   0.01%
/usr/local/libexec/nut/usbhid-ups -a cyberpower
93424 adam         20    0    21M  9900K select   0   0:00   0.01%
sshd: adam@pts/0 (sshd)

> ifconfig -vm
mlxen0: flags=8843<UP,BROADCAST,RUNNING,SIMPLEX,MULTICAST> metric 0 mtu 9000
options=ed07bb<RXCSUM,TXCSUM,VLAN_MTU,VLAN_HWTAGGING,JUMBO_MTU,VLAN_HWCSUM,TSO4,TSO6,LRO,VLAN_HWFILTER,VLAN_HWTSO,LINKSTATE,RXCSUM_IPV6,TXCSUM_IPV6>
capabilities=ed07bb<RXCSUM,TXCSUM,VLAN_MTU,VLAN_HWTAGGING,JUMBO_MTU,VLAN_HWCSUM,TSO4,TSO6,LRO,VLAN_HWFILTER,VLAN_HWTSO,LINKSTATE,RXCSUM_IPV6,TXCSUM_IPV6>
ether 00:02:c9:35:df:20
inet 10.5.5.1 netmask 0xffffff00 broadcast 10.5.5.255
media: Ethernet autoselect (40Gbase-CR4 <full-duplex,rxpause,txpause>)
status: active
supported media:
media autoselect
media 40Gbase-CR4 mediaopt full-duplex
media 10Gbase-CX4 mediaopt full-duplex
media 10Gbase-SR mediaopt full-duplex
media 1000baseT mediaopt full-duplex
nd6 options=29<PERFORMNUD,IFDISABLED,AUTO_LINKLOCAL>
plugged: QSFP+ 40GBASE-CR4 (No separable connector)
vendor: Mellanox PN: MC2207130-002 SN: MT1419VS07971 DATE: 2014-06-06
module temperature: 0.00 C voltage: 0.00 Volts
lane 1: RX power: 0.00 mW (-inf dBm) TX bias: 0.00 mA
lane 2: RX power: 0.00 mW (-inf dBm) TX bias: 0.00 mA
lane 3: RX power: 0.00 mW (-inf dBm) TX bias: 0.00 mA
lane 4: RX power: 0.00 mW (-inf dBm) TX bias: 0.00 mA

> - What are your values for:
>
> -- kern.ipc.maxsockbuf
> -- net.inet.tcp.sendbuf_max
> -- net.inet.tcp.recvbuf_max
>
> -- net.inet.tcp.sendspace
> -- net.inet.tcp.recvspace
>
> -- net.inet.tcp.delayed_ack
kern.ipc.maxsockbuf: 16777216
net.inet.tcp.sendbuf_max: 16777216
net.inet.tcp.recvbuf_max: 16777216
net.inet.tcp.sendspace: 32768 # This is interesting?  I'm not sure why
the discrepancy here
net.inet.tcp.recvspace: 4194304
net.inet.tcp.delayed_ack: 0

> netstat -i
Name    Mtu Network       Address              Ipkts Ierrs Idrop
Opkts Oerrs  Coll
igb0   9000 <Link#1>      ac:1f:6b:b0:60:bc 18230625     0     0
24178283     0     0
igb1   9000 <Link#2>      ac:1f:6b:b0:60:bc 14341213     0     0
8447249     0     0
lo0   16384 <Link#3>      lo0                 367691     0     0
367691     0     0
lo0       - localhost     localhost               68     -     -
68     -     -
lo0       - fe80::%lo0/64 fe80::1%lo0              0     -     -
 0     -     -
lo0       - your-net      localhost           348944     -     -
348944     -     -
mlxen  9000 <Link#4>      00:02:c9:35:df:20 13138046     0    12
26308206     0     0
mlxen     - 10.5.5.0/24   10.5.5.1          11592389     -     -
24345184     -     -
vm-pu  9000 <Link#6>      56:3e:55:8a:2a:f8     7270     0     0
962249   102     0
lagg0  9000 <Link#5>      ac:1f:6b:b0:60:bc 31543941     0     0
31623674     0     0
lagg0     - 192.168.0.0/2 nasbox            27967582     -     -
41779731     -     -

> What threads/irq are allocated to your NIC? 'vmstat -i'

Doesn't seem perfectly balanced but not terribly imbalanced, either:

interrupt                          total       rate
irq9: acpi0                            3          0
irq18: ehci0 ehci1+               803162          2
cpu0:timer                      67465114        167
cpu1:timer                      65068819        161
cpu2:timer                      65535300        163
cpu3:timer                      63408731        157
cpu4:timer                      63026304        156
cpu5:timer                      63431412        157
irq56: nvme0:admin                    18          0
irq57: nvme0:io0                  544999          1
irq58: nvme0:io1                  465816          1
irq59: nvme0:io2                  487486          1
irq60: nvme0:io3                  474616          1
irq61: nvme0:io4                  452527          1
irq62: nvme0:io5                  467807          1
irq63: mps0                     36110415         90
irq64: mps1                    112328723        279
irq65: mps2                     54845974        136
irq66: mps3                     50770215        126
irq68: xhci0                     3122136          8
irq70: igb0:rxq0                 1974562          5
irq71: igb0:rxq1                 3034190          8
irq72: igb0:rxq2                28703842         71
irq73: igb0:rxq3                 1126533          3
irq74: igb0:aq                         7          0
irq75: igb1:rxq0                 1852321          5
irq76: igb1:rxq1                 2946722          7
irq77: igb1:rxq2                 9602613         24
irq78: igb1:rxq3                 4101258         10
irq79: igb1:aq                         8          0
irq80: ahci1                    37386191         93
irq81: mlx4_core0                4748775         12
irq82: mlx4_core0               13754442         34
irq83: mlx4_core0                3551629          9
irq84: mlx4_core0                2595850          6
irq85: mlx4_core0                4947424         12
Total                          769135944       1908

> Are the above threads floating or mapped? 'cpuset -g ...'

I suspect I was supposed to run this against the argument of a pid,
maybe nfsd?  Here's the output without an argument

pid -1 mask: 0, 1, 2, 3, 4, 5
pid -1 domain policy: first-touch mask: 0

> Disable nfs tcp drc

This is the first I've even seen a duplicate request cache mentioned.
It seems counter-intuitive for why that'd help but maybe I'll try
doing that.  What exactly is the benefit?

> What is your atime setting?

Disabled at both the file system and the client mounts.

> You also state you are using a Linux client. Are you using the MLX affinity scripts, buffer sizing suggestions, etc, etc. Have you swapped the Linux system for a fbsd system?
I've not, though I do vaguely recall mellanox supplying some scripts
in their documentation that fixed interrupt handling on specific cores
at one point.  Is this what you're referring to?  I could give that a
try.  I don't at present have any FreeBSD client systems with enough
PCI express bandwidth to swap things out for a Linux vs FreeBSD test.

>  You mention iperf. Please post the options you used when invoking iperf and it's output.

Setting up the NFS client as a "server", since it seems that the
terminology is a little bit flipped with iperf, here's the output:

-----------------------------------------------------------
Server listening on 5201 (test #1)
-----------------------------------------------------------
Accepted connection from 10.5.5.1, port 11534
[  5] local 10.5.5.4 port 5201 connected to 10.5.5.1 port 43931
[ ID] Interval           Transfer     Bitrate
[  5]   0.00-1.00   sec  3.81 GBytes  32.7 Gbits/sec
[  5]   1.00-2.00   sec  4.20 GBytes  36.1 Gbits/sec
[  5]   2.00-3.00   sec  4.18 GBytes  35.9 Gbits/sec
[  5]   3.00-4.00   sec  4.21 GBytes  36.1 Gbits/sec
[  5]   4.00-5.00   sec  4.20 GBytes  36.1 Gbits/sec
[  5]   5.00-6.00   sec  4.21 GBytes  36.2 Gbits/sec
[  5]   6.00-7.00   sec  4.10 GBytes  35.2 Gbits/sec
[  5]   7.00-8.00   sec  4.20 GBytes  36.1 Gbits/sec
[  5]   8.00-9.00   sec  4.21 GBytes  36.1 Gbits/sec
[  5]   9.00-10.00  sec  4.20 GBytes  36.1 Gbits/sec
[  5]  10.00-10.00  sec  7.76 MBytes  35.3 Gbits/sec
- - - - - - - - - - - - - - - - - - - - - - - - -
[ ID] Interval           Transfer     Bitrate
[  5]   0.00-10.00  sec  41.5 GBytes  35.7 Gbits/sec                  receiver
-----------------------------------------------------------
Server listening on 5201 (test #2)
-----------------------------------------------------------

On Sun, May 22, 2022 at 3:45 AM John <jwd@freebsd.org> wrote:
>
> ----- Adam Stylinski's Original Message -----
> > Hello,
> >
> > I have two systems connected via ConnectX-3 mellanox cards in ethernet
> > mode.  They have their MTU's maxed at 9000, their ring buffers maxed
> > at 8192, and I can hit around 36 gbps with iperf.
> >
> > When using an NFS client (client = linux, server = freebsd), I see a
> > maximum rate of around 20gbps.  The test file is fully in ARC.  The
> > test is performed with an NFS mount nconnect=4 and an rsize/wsize of
> > 1MB.
> >
> > Here's the flame graph of the kernel of the system in question, with
> > idle stacks removed:
> >
> > https://gist.github.com/KungFuJesus/918c6dcf40ae07767d5382deafab3a52#file-nfs_fg-svg
> >
> > The longest functions seems like maybe it's the ERMS aware memcpy
> > happening from the ARC?  Is there maybe a missing fast path that could
> > take fewer copies into the socket buffer?
>
> Hi Adam -
>
>    Some items to look at and possibly include for more responses....
>
> - What is your server system? Make/model/ram/etc. What is your
>   overall 'top' cpu utilization 'top -aH' ...
>
> - It looks like you're using a 40gb/s card. Posting the output of
>   'ifconfig -vm' would provide additional information.
>
> - Are the interfaces running cleanly? 'netstat -i' is helpful.
>
> - Inspect 'netstat -s'. Duplicate pkts? Resends? Out-of-order?
>
> - Inspect 'netstat -m'. Denied? Delayed?
>
>
> - You mention iperf. Please post the options you used when
>   invoking iperf and it's output.
>
> - You appear to be looking for through-put vs low-latency. Have
>   you looked at window-size vs the amount of memory allocated to the
>   streams. These values vary based on the bit-rate of the connection.
>   Tcp connections require outstanding un-ack'd data to be held.
>   Effects values below.
>
>
> - What are your values for:
>
> -- kern.ipc.maxsockbuf
> -- net.inet.tcp.sendbuf_max
> -- net.inet.tcp.recvbuf_max
>
> -- net.inet.tcp.sendspace
> -- net.inet.tcp.recvspace
>
> -- net.inet.tcp.delayed_ack
>
> - What threads/irq are allocated to your NIC? 'vmstat -i'
>
> - Are the above threads floating or mapped? 'cpuset -g ...'
>
> - Determine best settings for LRO/TSO for your card.
>
> - Disable nfs tcp drc
>
> - What is your atime setting?
>
>
>    If you really think you have a ZFS/Kernel issue, and you're
> data fits in cache, dump ZFS, create a memory backed file system
> and repeat your tests. This will purge a large portion of your
> graph.  LRO/TSO changes may do so also.
>
>    You also state you are using a Linux client. Are you using
> the MLX affinity scripts, buffer sizing suggestions, etc, etc.
> Have you swapped the Linux system for a fbsd system?
>
>    And as a final note, I regularly use Chelsio T62100 cards
> in dual home and/or LACP environments in Supermicro boxes with 100's
> of nfs boot (Bhyve, QEMU, and physical system) clients per server
> with no network starvation or cpu bottlenecks.  Clients boot, perform
> their work, and then remotely request image rollback.
>
>
>    Hopefully the above will help and provide pointers.
>