Date: Fri, 24 Jul 1998 09:29:11 -0400 (EDT) From: "Patrick W. Bryant" <daspwb@Queequeg.Gsu.EDU> To: Doug Ledford <dledford@dialnet.net> Cc: aic7xxx Mailing List <AIC7xxx@FreeBSD.ORG> Subject: Follow up (Dell 410) Message-ID: <Pine.LNX.3.96.980724092308.1721A-100000@Queequeg.Gsu.EDU> In-Reply-To: <35B61488.982A2D5B@dialnet.net>
next in thread | previous in thread | raw e-mail | index | archive | help
OK, I removed the line Doug had suggested before (enableSE_high = enableSE_low = enableLVD_high = enableLVD_low = TRUE;) and now the drive is quiet. So far as I can tell, everything is working quite well! here's my earlier message in case this one gets to the list first ;-) >---------snip--------------< Wow: I disabled the BIOS for my aic7890 and voila! The machine boots and I can mount the drive that's on it. I'm using 2.0.35 (BTW, thanks for all the responses on obtaining the kernel source) with aic7xxx pre5, plus the change Doug recommended the other day . . . "enableSE_high = enableSE_low = enableLVD_high = enableLVD_low = TRUE;" . . . which didn't make any difference when I tried it yesterday. My machine is a Dell 410 Workstation SMP. The only problem now (so far) is, the drive is *really* noisy -- it's just buzzing away under my desk and driving me up the wall. Here's the stuff from proc in case it's useful: Adaptec AIC7xxx driver version: 5.1.0pre5/3.2.4 Compile Options: AIC7XXX_RESET_DELAY : 15 AIC7XXX_TAGGED_QUEUEING: Adapter Support Enabled Check below to see which devices use tagged queueing AIC7XXX_PAGE_ENABLE : Enabled (This is no longer an option) AIC7XXX_PROC_STATS : Disabled Adapter Configuration: SCSI Adapter: Adaptec AIC-7890/1 Ultra2 SCSI host adapter Ultra2-SE Wide Controller PCI MMAPed I/O Base: 0xf9fff000 Adaptec SCSI BIOS: Disabled IRQ: 10 SCBs: Active 0, Max Active 1, Allocated 30, HW 32, Page 255 Interrupts: 90 BIOS Control Word: 0x18a2 Adapter Control Word: 0x1c5c Extended Translation: Enabled Disconnect Enable Flags: 0xffff Ultra Enable Flags: 0x0000 Tag Queue Enable Flags: 0x0000 Ordered Queue Tag Flags: 0x0000 Default Tag Queue Depth: 8 Tagged Queue By Device array for aic7xxx host instance 1: {255,255,255,255,255,255,255,255,255,255,255,255,255,255,255,255} Actual queue depth per device for aic7xxx host instance 1: {1,1,1,1,1,1,1,1,1,1,1,1,1,1,1,1} Statistics: (scsi1:0:0:0) Device using Wide/Sync transfers at 80.0 MByte/sec, offset 31 Total transfers 36 (36 read;0 written) blks(512) rd=39; blks(512) wr=0 -P ______________________________ P a t r i c k W. B r y a n t College of Arts & Sciences Internet Technology Services To Unsubscribe: send mail to majordomo@FreeBSD.org with "unsubscribe aic7xxx" in the body of the message
Want to link to this message? Use this URL: <https://mail-archive.FreeBSD.org/cgi/mid.cgi?Pine.LNX.3.96.980724092308.1721A-100000>