Date: Thu, 01 Jun 2017 10:37:26 +0100 From: Pete French <petefrench@ingresso.co.uk> To: bapt@FreeBSD.org, petefrench@ingresso.co.uk, petefrench@ingresso.co.uk Cc: stable@freebsd.org Subject: Re: 11.1-PRERELEASE, waagent crashes attaching reosurce disc in Azure Message-ID: <E1dGMXm-000682-JX@dilbert.ingresso.co.uk>
next in thread | raw e-mail | index | archive | help
Just been through the azure python code - my intiial impressin was wrong, its not the chnage to the periphlist output which is the issue. Instead its the fact that a simple 'devlist' now puts the pass devices first in the list, and the azure waagent uses the first listed device when it initially looks for the device. A simple fix for this is to reject what that call returns and then to drop back to using periphlist, nd this is what I have done, but it would be nice to fix it properly. What was the reason behind the chnage of ordering anyway ? Any script which naiively parses the output of camcontrol devlist will hit a similar issue potentially ? It's not exactly a bug, but... -pete.