Skip site navigation (1)Skip section navigation (2)
Date:      Fri, 21 Jun 2019 14:46:43 +0000 (UTC)
From:      Ian Lepore <ian@FreeBSD.org>
To:        src-committers@freebsd.org, svn-src-all@freebsd.org, svn-src-head@freebsd.org
Subject:   svn commit: r349271 - head/share/man/man9
Message-ID:  <201906211446.x5LEkhS8098472@repo.freebsd.org>

next in thread | raw e-mail | index | archive | help
Author: ian
Date: Fri Jun 21 14:46:43 2019
New Revision: 349271
URL: https://svnweb.freebsd.org/changeset/base/349271

Log:
  Catch up with recent changes in pwmbus(9).  The pwm(9) and pwmbus(9)
  interfaces were unified into pwmbus(9), and the PWMBUS_CHANNEL_MAX method
  was renamed PWMBUS_CHANNEL_COUNT.  The pwmbus_attach_bus() function just
  went away completely.  Also, fix a few typos such as s/is/if/.

Deleted:
  head/share/man/man9/pwm.9
Modified:
  head/share/man/man9/Makefile
  head/share/man/man9/pwmbus.9

Modified: head/share/man/man9/Makefile
==============================================================================
--- head/share/man/man9/Makefile	Fri Jun 21 14:24:33 2019	(r349270)
+++ head/share/man/man9/Makefile	Fri Jun 21 14:46:43 2019	(r349271)
@@ -270,7 +270,6 @@ MAN=	accept_filter.9 \
 	proc_rwmem.9 \
 	pseudofs.9 \
 	psignal.9 \
-	pwm.9 \
 	pwmbus.9 \
 	random.9 \
 	random_harvest.9 \
@@ -1670,6 +1669,7 @@ MLINKS+=proc_rwmem.9 proc_readmem.9 \
 MLINKS+=psignal.9 gsignal.9 \
 	psignal.9 pgsignal.9 \
 	psignal.9 tdsignal.9
+MLINKS+=pwmbus.9 pwm.9
 MLINKS+=random.9 arc4rand.9 \
 	random.9 arc4random.9 \
 	random.9 is_random_seeded.9 \

Modified: head/share/man/man9/pwmbus.9
==============================================================================
--- head/share/man/man9/pwmbus.9	Fri Jun 21 14:24:33 2019	(r349270)
+++ head/share/man/man9/pwmbus.9	Fri Jun 21 14:46:43 2019	(r349271)
@@ -22,12 +22,11 @@
 .\"
 .\" $FreeBSD$
 .\"
-.Dd November 12, 2018
+.Dd June 21, 2019
 .Dt PWMBUS 9
 .Os
 .Sh NAME
 .Nm pwmbus ,
-.Nm pwmbus_attach_bus ,
 .Nm PWMBUS_GET_BUS ,
 .Nm PWMBUS_CHANNEL_CONFIG ,
 .Nm PWMBUS_CHANNEL_GET_CONFIG ,
@@ -40,8 +39,6 @@
 .Sh SYNOPSIS
 .Cd "device pwm"
 .In "pwmbus_if.h"
-.Ft device_t
-.Fn pwmbus_attach_bus "device_t dev"
 .Ft int
 .Fn PWMBUS_CHANNEL_CONFIG "device_t bus" "int channel" "uint64_t period" "uint64_t duty"
 .Ft int
@@ -55,37 +52,35 @@
 .Ft int
 .Fn PWMBUS_CHANNEL_IS_ENABLED "device_t bus" "int channel" "bool *enabled"
 .Ft int
-.Fn PWMBUS_CHANNEL_MAX "device_t bus" "int channel" "int *nchannel"
+.Fn PWMBUS_CHANNEL_COUNT "device_t bus" "int channel" "int *nchannel"
 .Sh DESCRIPTION
 The PWMBUS (Pulse-Width Modulation) interface allows the device driver to register to a global
-bus so other devices in the kernel can use them in a generic way
+bus so other devices in the kernel can use them in a generic way.
 .Sh INTERFACE
 .Bl -tag -width indent
-.It Fn pwmbus_attach_bus "device_t dev"
-Attach the
-.Nm pwmbus
-to the device driver
 .It Fn PWMBUS_CHANNEL_CONFIG "device_t bus" "int channel" "uint64_t period" "uint64_t duty"
 Configure the period and duty (in nanoseconds) in the PWM controller on the bus for the specified channel.
 Returns 0 on success or
 .Er EINVAL
-is the values are not supported by the controller or
+if the values are not supported by the controller or
 .Er EBUSY
-is the PWMBUS controller is in use and doesn't support changing the value on the fly.
+if the PWMBUS controller is in use and doesn't support changing the value on the fly.
 .It Fn PWMBUS_CHANNEL_GET_CONFIG "device_t bus" "int channel" "uint64_t *period" "uint64_t *duty"
 Get the current configuration of the period and duty for the specified channel.
 .It Fn PWMBUS_CHANNEL_SET_FLAGS "device_t bus" "int channel" "uint32_t flags"
-Set the flags of the channel (like inverted polarity), if the driver or controller
-doesn't support this a default method is used.
+Set the flags of the channel (such as inverted polarity), if the driver or controller
+doesn't support this a do-nothing default method is used.
 .It Fn PWMBUS_CHANNEL_GET_FLAGS "device_t bus" "int channel" "uint32_t *flags"
-Get the current flags for the channel, if the driver or controller
-doesn't support this, a default method is used.
+Get the current flags for the channel.
+If the driver or controller
+doesn't support this, a default method returns a flags value of zero.
 .It Fn PWMBUS_CHANNEL_ENABLE "device_t bus" "int channel" "bool enable"
 Enable the PWM channel.
 .It Fn PWMBUS_CHANNEL_ISENABLED "device_t bus" "int channel" "bool *enable"
 Test if the PWM channel is enabled.
-.It PWMBUS_CHANNEL_MAX "device_t bus" "int channel" "int *nchannel"
-Get the maximum number of channel supported by the controller.
+.It PWMBUS_CHANNEL_COUNT "device_t bus" "int channel" "int *nchannel"
+Get the number of channels supported by the controller.
+Channel numbers count up from zero.
 .El
 .Sh HISTORY
 The