Skip site navigation (1)Skip section navigation (2)
Date:      Mon, 18 Aug 2014 11:36:21 +0000
From:      bugzilla-noreply@freebsd.org
To:        freebsd-bugs@FreeBSD.org
Subject:   [Bug 191348] [mps] LSI2308 with WD3000FYYZ drives disappears after hotswapping
Message-ID:  <bug-191348-8-YaoMZKQfPp@https.bugs.freebsd.org/bugzilla/>
In-Reply-To: <bug-191348-8@https.bugs.freebsd.org/bugzilla/>
References:  <bug-191348-8@https.bugs.freebsd.org/bugzilla/>

next in thread | previous in thread | raw e-mail | index | archive | help

https://bugs.freebsd.org/bugzilla/show_bug.cgi?id=191348

--- Comment #8 from MichaƂ Margula <alchemyx@uznam.net.pl> ---
Hello,

First of all - thank you for your help and time spent on that issue. Also I am
sorry that it took so long for me to respond, but I had upgrade that box to
FreeBSD 10.0 (it was 9.2 because of that issue) and then recompiled kernel.

It seems that issue is fixed by that delay of 3 seconds. I see that "sleeping"
message everytime I disconnect and reconnect drive. But now drive is detected
properly after replacing. 

Currently I have some issues with "zpool status" showing those drives as
faulted but it may be some kind of my fault when trying to online them. I will
get back to you as soon drives get resilvered and I can do some more testing.

BTW - is it possible that such delay could be introduced in drivers by default
(or maybe as module option) or will I have to recompile kernel everytime?

Thank you once more!

-- 
You are receiving this mail because:
You are the assignee for the bug.


Want to link to this message? Use this URL: <https://mail-archive.FreeBSD.org/cgi/mid.cgi?bug-191348-8-YaoMZKQfPp>