Skip site navigation (1)Skip section navigation (2)
Date:      Fri, 18 Jan 2002 10:00:02 -0800 (PST)
From:      Garrett Wollman <wollman@khavrinen.lcs.mit.edu>
To:        freebsd-bugs@FreeBSD.org
Subject:   kern/34017: The siginfo_t passed to the signal handling routine is not filled out for AIO
Message-ID:  <200201181800.g0II02I84460@freefall.freebsd.org>

next in thread | raw e-mail | index | archive | help
The following reply was made to PR kern/34017; it has been noted by GNATS.

From: Garrett Wollman <wollman@khavrinen.lcs.mit.edu>
To: Kip Macy <kip@eventdriven.org>
Cc: freebsd-gnats-submit@FreeBSD.ORG
Subject: kern/34017: The siginfo_t passed to the signal handling routine is not filled out for AIO
Date: Fri, 18 Jan 2002 12:57:56 -0500 (EST)

 <<On Thu, 17 Jan 2002 21:59:08 -0800 (PST), Kip Macy <kip@eventdriven.org> said:
 
 > One can, when using AIO, enable a signal to be delivered on completion.
 > The siginfo_t passed to the signal handling routine that gets called on
 > completion is supposed to have a reference to the sigev_value that is
 > set when the aio_* operation is dispatched. This does not happen.
 
 FreeBSD does not support POSIX real-time signals.
 
 -GAWollman
 

To Unsubscribe: send mail to majordomo@FreeBSD.org
with "unsubscribe freebsd-bugs" in the body of the message