Hello!
I've noticed wierd behavior of pf port redirection. I have FreeBSD 8.2 box
which nat'ed my lan. There are some http/mail servers presented in lan, tcp
port redirection work fine, but udp redirection to my H323 enabled device is
strange.
When I initialising call , replied udp packets successfully redirected to
my h323 device, but if call is initialising from outside to me -
redirection just not work (I can't hear remote peer). I see udp packets hit
to my ext_if , but nothing appear in lan_if.
pf.conf
nat pass on $inet_if from $lan_net to any -> $inet_if
rdr pass on $inet_if proto tcp from any to $inet_ip port {25,80} -> 10.0.0.2
# Work fine
rdr pass on $inet_if proto tcp from any to $inet_ip port 1720 -> 10.0.0.4 #
Work fine
rdr pass on $inet_if proto udp from any to $inet_ip port 2048:2063 ->
10.0.0.4 # Work only if I initialising call
pass all
Also I tried to adjust udp session timer:
set timeout udp.first 300
set timeout udp.single 150
set timeout udp.multiple 900
Is this pf bug or I something misconfigured pf.conf?