Date: Sat, 21 Jun 1997 05:19:58 -0700 From: "Jordan K. Hubbard" <jkh@time.cdrom.com> To: "Tom T. Thai" <tomthai@future.net> Cc: freebsd-isp@FreeBSD.ORG Subject: Re: ISDN Message-ID: <10309.866895598@time.cdrom.com> In-Reply-To: Your message of "Sat, 21 Jun 1997 05:35:47 CDT." <Pine.BSD.3.91.970621052832.24384A-100000@dream.future.net>
next in thread | previous in thread | raw e-mail | index | archive | help
> 1. If I had a BRI line and a TA attached to it, the TA can only handle > one B channel at a time right? If yes, then would I be wasting the 2nd B Wrong. You can bond two B channels just fine with a TA. I do it all the time. > 2. If I had the same setup as #1, and a user want to do 128K (both B > channels), do I have to setup anything special on the RAS? Or can I You can't do 128K, but you can do 115.2K. > 3. What is a good TA if I want to do 128K on the server side to a smart > multiserial RAS? Hard to say - depends on the RAS. Most modern TAs will do multilink PPP, but you'd need to make sure it's interoperable with the RAS. I just use a TA on each end for my link and let them speak their own bonding protocol ("bonding mode 1" for the ADTRAN L1) so it works seamlessly. Jordan