Skip site navigation (1)Skip section navigation (2)
Date:      Thu, 21 May 2009 18:55:46 +0200
From:      Riccardo Torrini <riccardo.torrini@esaote.com>
To:        Attilio Rao <attilio@freebsd.org>
Cc:        freebsd-stable@freebsd.org, siedar@nplay.pl, scottl@freebsd.org, Riccardo Torrini <riccardo.torrini@esaote.com>, John Baldwin <jhb@freebsd.org>
Subject:   Re: kern/130330: [mpt] [panic] Panic and reboot machine MPT ...
Message-ID:  <20090521165546.GL21112@tiger.fi.esaote.it>
In-Reply-To: <3bbf2fe10905210247n183812dbu5addb4f8b2214a76@mail.gmail.com>
References:  <20090507155012.GW21112@tiger.fi.esaote.it> <200905121144.21406.jhb@freebsd.org> <20090512161025.GO21112@tiger.fi.esaote.it> <200905201021.23633.jhb@freebsd.org> <20090521072922.GR21112@tiger.fi.esaote.it> <3bbf2fe10905210247n183812dbu5addb4f8b2214a76@mail.gmail.com>

next in thread | previous in thread | raw e-mail | index | archive | help
On Thu, May 21, 2009 at 11:47:54AM +0200, Attilio Rao wrote:

> Please try the patch here:
> http://www.freebsd.org/~attilio/notify.diff

As promised I checked againts 7.2-STABLE of today (cvsup ended
at 15:17 CEST, GTM+2, Italy time with DST) and ... it works !
(added and removed a disk 4 times, even during a sync-in-progress)

# uname -v
FreeBSD 7.2-STABLE #3: Thu May 21 18:26:04 CEST 2009 ...


-----[ 1st remove ]-----

mpt0: External Bus Reset Detected
(mpt0:vol0:1): Physical Disk Status Changed
(mpt0:vol0:0): Volume Status Changed
(mpt0:vol0:1): Physical Disk Status Changed
mpt0:vol0(mpt0:0:0): RAID-1 - Degraded
mpt0:vol0(mpt0:0:0): Status ( Enabled )
(mpt0:vol0:1): No longer configured

-----[ 1st add ]-----
mpt0: External Bus Reset Detected
mpt0:vol0(mpt0:0:0): Physical Disk Status Changed
mpt0:vol0(mpt0:0:0): Physical Disk Status Changed
mpt0:vol0(mpt0:0:0): Physical Disk Status Changed
mpt0:vol0(mpt0:0:0): Domain Validation Required
mpt0:vol0(mpt0:0:0): Volume Status Changed
mpt0:vol0(mpt0:0:0): RAID-1 - Degraded
mpt0:vol0(mpt0:0:0): Status ( Enabled Re-Syncing )
mpt0:vol0(mpt0:0:0): Low Priority Re-Sync
mpt0:vol0(mpt0:0:0): 71087625 of 71087625 blocks remaining
(mpt0:vol0:1): Physical (mpt0:0:1:0), Pass-thru (mpt0:1:1:0)
(mpt0:vol0:1): Online
(mpt0:vol0:1): Status ( Out-Of-Sync )
(mpt0:vol0:1): SMART Data Received
(mpt0:vol0:1): ASC 0x5d, ASCQ 0x0)
mpt0:vol0(mpt0:0:0): RAID-1 - Degraded
mpt0:vol0(mpt0:0:0): Status ( Enabled Re-Syncing )
mpt0:vol0(mpt0:0:0): Low Priority Re-Sync
mpt0:vol0(mpt0:0:0): 71076421 of 71087625 blocks remaining
mpt0:vol0(mpt0:0:0): Volume Status Changed


-----[ 2nd remove ]-----
mpt0: External Bus Reset Detected
mpt0:vol0(mpt0:0:0): RAID-1 - Degraded
mpt0:vol0(mpt0:0:0): Status ( Enabled )
(mpt0:vol0:1): Physical Disk Status Changed
(mpt0:vol0:1): Physical Disk Status Changed
(mpt0:vol0:1): No longer configured
mpt0:vol0(mpt0:0:0): Physical Disk Status Changed

-----[ 2nd add ]-----
mpt0: External Bus Reset Detected
mpt0:vol0(mpt0:0:0): Physical Disk Status Changed
mpt0:vol0(mpt0:0:0): Physical Disk Status Changed
mpt0:vol0(mpt0:0:0): Physical Disk Status Changed
mpt0:vol0(mpt0:0:0): Domain Validation Required
mpt0:vol0(mpt0:0:0): Volume Status Changed
mpt0:vol0(mpt0:0:0): RAID-1 - Degraded
mpt0:vol0(mpt0:0:0): Status ( Enabled Re-Syncing )
mpt0:vol0(mpt0:0:0): Low Priority Re-Sync
mpt0:vol0(mpt0:0:0): 71087625 of 71087625 blocks remaining
(mpt0:vol0:1): Physical (mpt0:0:1:0), Pass-thru (mpt0:1:1:0)
(mpt0:vol0:1): Online
(mpt0:vol0:1): Status ( Out-Of-Sync )
(mpt0:vol0:1): SMART Data Received
(mpt0:vol0:1): ASC 0x5d, ASCQ 0x0)
mpt0:vol0(mpt0:0:0): RAID-1 - Degraded
mpt0:vol0(mpt0:0:0): Status ( Enabled Re-Syncing )
mpt0:vol0(mpt0:0:0): Low Priority Re-Sync
mpt0:vol0(mpt0:0:0): 70896522 of 71087625 blocks remaining


Thanks again.


-- 
Riccardo.