Date: Thu, 21 May 2009 18:55:46 +0200 From: Riccardo Torrini <riccardo.torrini@esaote.com> To: Attilio Rao <attilio@freebsd.org> Cc: freebsd-stable@freebsd.org, siedar@nplay.pl, scottl@freebsd.org, Riccardo Torrini <riccardo.torrini@esaote.com>, John Baldwin <jhb@freebsd.org> Subject: Re: kern/130330: [mpt] [panic] Panic and reboot machine MPT ... Message-ID: <20090521165546.GL21112@tiger.fi.esaote.it> In-Reply-To: <3bbf2fe10905210247n183812dbu5addb4f8b2214a76@mail.gmail.com> References: <20090507155012.GW21112@tiger.fi.esaote.it> <200905121144.21406.jhb@freebsd.org> <20090512161025.GO21112@tiger.fi.esaote.it> <200905201021.23633.jhb@freebsd.org> <20090521072922.GR21112@tiger.fi.esaote.it> <3bbf2fe10905210247n183812dbu5addb4f8b2214a76@mail.gmail.com>
next in thread | previous in thread | raw e-mail | index | archive | help
On Thu, May 21, 2009 at 11:47:54AM +0200, Attilio Rao wrote: > Please try the patch here: > http://www.freebsd.org/~attilio/notify.diff As promised I checked againts 7.2-STABLE of today (cvsup ended at 15:17 CEST, GTM+2, Italy time with DST) and ... it works ! (added and removed a disk 4 times, even during a sync-in-progress) # uname -v FreeBSD 7.2-STABLE #3: Thu May 21 18:26:04 CEST 2009 ... -----[ 1st remove ]----- mpt0: External Bus Reset Detected (mpt0:vol0:1): Physical Disk Status Changed (mpt0:vol0:0): Volume Status Changed (mpt0:vol0:1): Physical Disk Status Changed mpt0:vol0(mpt0:0:0): RAID-1 - Degraded mpt0:vol0(mpt0:0:0): Status ( Enabled ) (mpt0:vol0:1): No longer configured -----[ 1st add ]----- mpt0: External Bus Reset Detected mpt0:vol0(mpt0:0:0): Physical Disk Status Changed mpt0:vol0(mpt0:0:0): Physical Disk Status Changed mpt0:vol0(mpt0:0:0): Physical Disk Status Changed mpt0:vol0(mpt0:0:0): Domain Validation Required mpt0:vol0(mpt0:0:0): Volume Status Changed mpt0:vol0(mpt0:0:0): RAID-1 - Degraded mpt0:vol0(mpt0:0:0): Status ( Enabled Re-Syncing ) mpt0:vol0(mpt0:0:0): Low Priority Re-Sync mpt0:vol0(mpt0:0:0): 71087625 of 71087625 blocks remaining (mpt0:vol0:1): Physical (mpt0:0:1:0), Pass-thru (mpt0:1:1:0) (mpt0:vol0:1): Online (mpt0:vol0:1): Status ( Out-Of-Sync ) (mpt0:vol0:1): SMART Data Received (mpt0:vol0:1): ASC 0x5d, ASCQ 0x0) mpt0:vol0(mpt0:0:0): RAID-1 - Degraded mpt0:vol0(mpt0:0:0): Status ( Enabled Re-Syncing ) mpt0:vol0(mpt0:0:0): Low Priority Re-Sync mpt0:vol0(mpt0:0:0): 71076421 of 71087625 blocks remaining mpt0:vol0(mpt0:0:0): Volume Status Changed -----[ 2nd remove ]----- mpt0: External Bus Reset Detected mpt0:vol0(mpt0:0:0): RAID-1 - Degraded mpt0:vol0(mpt0:0:0): Status ( Enabled ) (mpt0:vol0:1): Physical Disk Status Changed (mpt0:vol0:1): Physical Disk Status Changed (mpt0:vol0:1): No longer configured mpt0:vol0(mpt0:0:0): Physical Disk Status Changed -----[ 2nd add ]----- mpt0: External Bus Reset Detected mpt0:vol0(mpt0:0:0): Physical Disk Status Changed mpt0:vol0(mpt0:0:0): Physical Disk Status Changed mpt0:vol0(mpt0:0:0): Physical Disk Status Changed mpt0:vol0(mpt0:0:0): Domain Validation Required mpt0:vol0(mpt0:0:0): Volume Status Changed mpt0:vol0(mpt0:0:0): RAID-1 - Degraded mpt0:vol0(mpt0:0:0): Status ( Enabled Re-Syncing ) mpt0:vol0(mpt0:0:0): Low Priority Re-Sync mpt0:vol0(mpt0:0:0): 71087625 of 71087625 blocks remaining (mpt0:vol0:1): Physical (mpt0:0:1:0), Pass-thru (mpt0:1:1:0) (mpt0:vol0:1): Online (mpt0:vol0:1): Status ( Out-Of-Sync ) (mpt0:vol0:1): SMART Data Received (mpt0:vol0:1): ASC 0x5d, ASCQ 0x0) mpt0:vol0(mpt0:0:0): RAID-1 - Degraded mpt0:vol0(mpt0:0:0): Status ( Enabled Re-Syncing ) mpt0:vol0(mpt0:0:0): Low Priority Re-Sync mpt0:vol0(mpt0:0:0): 70896522 of 71087625 blocks remaining Thanks again. -- Riccardo.
Want to link to this message? Use this URL: <https://mail-archive.FreeBSD.org/cgi/mid.cgi?20090521165546.GL21112>