Date: Tue, 25 Aug 1998 15:53:48 +0800 From: Stephen Hocking-Senior Programmer PGS Tensor Perth <shocking@prth.pgs.com> To: current@FreeBSD.ORG Subject: Floating Point Exceptions, signal handlers & subsequent ops Message-ID: <199808250753.PAA29567@ariadne.tensor.pgs.com>
next in thread | raw e-mail | index | archive | help
I've noticed in one of my applications that the first FP operation after return from a caught SIGFPE is invalid. I have a signal handler installed that just prints out some basic info (like "SIGFPE caught"). The first FP op after this (in my case, converting a long to a double) just gives garbage. Repeat the same statement and it gives a sensible result. Has anyone else seen this before I file a PR with code to reproduce the problem? Stephen -- The views expressed above are not those of PGS Tensor. "We've heard that a million monkeys at a million keyboards could produce the Complete Works of Shakespeare; now, thanks to the Internet, we know this is not true." Robert Wilensky, University of California To Unsubscribe: send mail to majordomo@FreeBSD.org with "unsubscribe freebsd-current" in the body of the message
Want to link to this message? Use this URL: <https://mail-archive.FreeBSD.org/cgi/mid.cgi?199808250753.PAA29567>