Date: Fri, 20 Aug 2004 02:26:44 +0400 From: Roman Kurakin <rik@cronyx.ru> To: freebsd-current@freebsd.org Subject: Tracking down LORs Message-ID: <41252924.4020305@cronyx.ru>
next in thread | raw e-mail | index | archive | help
Hi, Currently I am trying to track down a couple of LORS in my code. But it seems that I do not undestand smth or all things id realy so bad. So I want to ask some questions to find out if my thoughts correct or wrong. 1. If I am right LOR means that we have at least two mutexs. Lets call them a and b. If we set a, then b in first case and b then a in second we could get dead loop, and thus LOR. 2. If I have some driver that have mutex a, and we have some sytem code that could call this driver with Giant (b), we would get LOR if driver lock a and some other part of system will try to lock Giant? or I am wrong? rik