Skip site navigation (1)Skip section navigation (2)
Date:      Sun, 3 Oct 2004 19:50:49 -0300 (ADT)
From:      "Marc G. Fournier" <scrappy@hub.org>
To:        freebsd-scsi@freebsd.org
Subject:   replacing a failed drive with hardware raid ...
Message-ID:  <20041003194841.N96717@ganymede.hub.org>
Resent-Message-ID: <20041003203856.O96717@ganymede.hub.org>

next in thread | raw e-mail | index | archive | help

never having done it before, I don't know how to do it :(  vinum is easy 
... replace the drive, make sure its partitioned right and start it ...

I have an IIR controller, with the storcon utility from the command line 
... drive 3 has failed, and I have a 'good drive' in slot 6 that is 
sitting idle ... the server is hot-swapable, so I should just need to pull 
out drive 3, put drive 6 in ... but what do I have to do in storcon to 
tell it to 'rebuild/start' the new drive?

Thanks ...

----
Marc G. Fournier           Hub.Org Networking Services (http://www.hub.org)
Email: scrappy@hub.org           Yahoo!: yscrappy              ICQ: 7615664
_______________________________________________
freebsd-scsi@freebsd.org mailing list
http://lists.freebsd.org/mailman/listinfo/freebsd-scsi
To unsubscribe, send any mail to "freebsd-scsi-unsubscribe@freebsd.org"