njl         2005-07-25 17:44:10 UTC

  FreeBSD src repository

  Modified files:
    sys/dev/acpica       acpi_battery.c 
  Log:
  Correct minor output bug.  When the battery being queried is charging or
  the overall discharge rate is 0, mark the battery remaining time as
  "unknown", not 0.
  
  Reported by:    Eric Kjeldergaard
  MFC after:      4 days
  
  Revision  Changes    Path
  1.14      +7 -0      src/sys/dev/acpica/acpi_battery.c