Date: Thu, 19 Aug 2004 23:28:26 -0700 From: Sean McNeil <sean@mcneil.com> To: freebsd-current@freebsd.org Subject: re fails diagnostics when heavy traffic Message-ID: <1092983306.28739.5.camel@server.mcneil.com>
next in thread | raw e-mail | index | archive | help
I've just figured this out. At times, my re0 device would not show up and I'd have to reboot once or twice before it worked. Then I noticed I couldn't get it at all and it turned out it was because I was streaming some heavy data at the time. Then I noticed it was failing because of the following: Aug 19 20:52:01 server kernel: rgephy0: <RTL8169S/8110S media interface> on miibus1 Aug 19 20:52:01 server kernel: rgephy0: 10baseT, 10baseT-FDX, 100baseTX, 100baseTX-FDX, 1000baseTX, 1000baseTX-FDX, auto Aug 19 20:52:01 server kernel: re0: Ethernet address: 00:0c:76:e9:2c:58 Aug 19 20:52:01 server kernel: re0: diagnostic failed, failed to receive packet in loopback mode Aug 19 20:52:01 server kernel: re0: attach aborted due to hardware diag failure Anything I can do to assist in fixing this please let me know. It has been a frustrating issue. Cheers, Sean
Want to link to this message? Use this URL: <https://mail-archive.FreeBSD.org/cgi/mid.cgi?1092983306.28739.5.camel>