Date: Wed, 30 Jun 1999 13:20:07 -0700 (PDT) From: Daniel Lang <dl@leo.org> To: freebsd-bugs@FreeBSD.org Subject: Re: kern/12395: Buslogic SCSI cards (BT948) time out under light loads on several different servers Message-ID: <199906302020.NAA58106@freefall.freebsd.org>
next in thread | raw e-mail | index | archive | help
The following reply was made to PR kern/12395; it has been noted by GNATS. From: Daniel Lang <dl@leo.org> To: freebsd-gnats-submit@freebsd.org, jim@web-ex.com Cc: Subject: Re: kern/12395: Buslogic SCSI cards (BT948) time out under light loads on several different servers Date: Wed, 30 Jun 1999 22:09:23 +0200 Hi, I've experienced similar problems with a BT 946C (1995). As the 'hanging' SCSI ID displayed always referred to the second harddisk, I thought, I have a problem with that one. So I sucked the data as long as it worked, and bought a new one (updated the System in between, so that it runs currently a 3.2-STABLE). But the problems still occur, just less often. No worries for the additional harddisk, i would have needed it anyway, but then I thougth about buying a new hostadapter. Well if it could be problem with the driver, and it seems that way, I would save that. :-) Cheers, Daniel -- IRCnet: Mr-Spock - May His Shadow fall upon thee - RL: Daniel Lang * dl@leo.org * +49 89 8540017 * http://www.leo.org/~dl/ To Unsubscribe: send mail to majordomo@FreeBSD.org with "unsubscribe freebsd-bugs" in the body of the message